Warning Icon 114 Installation may only be performed by a qualified electrician or similarly qualified person.

1. Arrangement:

SENTIOTEC FTS2 Humidity Temperature Sensor 0

  1. Heater sensor F1 in the area above the heating system
  2. Humidity- Temperature sensor FTS2
  3. Heating system Evaporator

SENTIOTEC FTS2 Humidity Temperature Sensor 1

  1. white (red)
  2. yellow (orange)
  3. green
  4. brown
  5. grey (black)
2. Installation:

1. Step: Drill a hole Ø 30 – 40 mm in the middle of a cabin wall panel. Keep 150 mm distance to the ceiling.

SENTIOTEC FTS2 Humidity Temperature Sensor 2

2. Step: Pull the connecting line (5-wire) coming from the control unit through the hole from the outer side of the cabin. Connect the wires with the clamps, put it back through the hole and fix the sensor case.

SENTIOTEC FTS2 Humidity Temperature Sensor 3

  1. 2 wood screws 4 x 16
3. Connection:

PRO-series

SENTIOTEC FTS2 Humidity Temperature Sensor 4

  1. brown
  2. grey (black)
  3. green
  4. yellow (orange)
  5. white (red )

wave.com4 11kW

sw …. grey (black)
br ….. brown
gn …. green
or ….. yellow (orange)
rt …… white (red)

FTS2
sw br gn or rt
F2 WC4-H-H
ws ws br bl ge/gn

home.com4

SENTIOTEC FTS2 Humidity Temperature Sensor 5

  1. green
  2. yellow (orange)
  3. grey (black)
  4. brown
  5. white (red)

Version 10/24                              1-043-927