Features
- Universal AC input / Full range
- Optional L-Bracket and cover
- High efficiency up to 90%
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- 4″ x 2″ compact size
- LED indicator for power on
- No load power consumption<0.3W
- Operating altitude up to 4000 meters
- 3 years warranty
SPECIFICATION
MODEL | EPS-65-3.3 | EPS-65-5 | EPS-65-7.5 | EPS-65-12 | EPS-65-15 | EPS-65-24 | EPS-65-36 | EPS-65-48 | |
OUTPUT | DC VOLTAGE | 3.3V | 5V | 7.5V | 12V | 15V | 24V | 36V | 48V |
RATED CURRENT | 11A | 11A | 8A | 5.42A | 4.34A | 2.71A | 1.81A | 1.36A | |
CURRENT RANGE | 0 ~ 12A | 0 ~ 12A | 0 ~ 8.8A | 0 ~ 6A | 0 ~ 4.8A | 0 ~ 3A | 0 ~ 2A | 0 ~ 1.5A | |
RATED POWER | 36.3W | 55W | 60W | 65.04W | 65.1W | 65.04W | 65.16W | 65.28W | |
PEAK LOAD(10sec.) Note.6 | 39.6W | 60W | 66W | 72W | 72W | 72W | 72W | 72W | |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 80mVp-p | 100mVp-p | 120mVp-p | 150mVp-p | 240mVp-p | 280mVp-p | 300mVp-p | |
VOLTAGE ADJ. RANGE | 3.1 ~ 3.6V | 4.75 ~ 5.5V | 7.13 ~ 8.25V | 10.8 ~ 13.5V | 13.5 ~ 16.5V | 21.6 ~ 27V | 32.4 ~ 39.6V | 43.2 ~ 52.8V | |
VOLTAGE TOLERANCE Note.3 | ±3.0% | ±2.0% | ±2.0% | ±2.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
SETUP, RISE TIME | 1000ms, 50ms/230VAC 2000ms, 50ms/115VAC at full load | ||||||||
HOLD UP TIME (Typ.) | 50ms/230VAC 12ms/115VAC at full load | ||||||||
INPUT | VOLTAGE RANGE Note.5 | 90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/N(+), AC/L(-)] | |||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||
EFFICIENCY (Typ.) | 80% | 82% | 84% | 86% | 87% | 88% | 89% | 90% | |
AC CURRENT (Typ.) | 1.8A/115VAC 1 A/230VAC | ||||||||
INRUSH CURRENT (Typ.) | COLD START 60A/230VAC | ||||||||
LEAKAGE CURRENT | <2mA/240VAC | ||||||||
PROTECTION | OVER LOAD | 115 ~ 180% rated output power | |||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||||
OVER VOLTAGE | 3.7 ~ 4.45V | 5.6 ~ 6.75V | 8.63 ~ 10.1V | 13.8 ~ 16.2V | 17.25 ~ 20.25V | 27.6 ~ 32.4V | 39.7 ~ 46.8V | 53.3 ~ 64.8V | |
Protection type : Shut down o/p voltage, re-power on to recover | |||||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70℃ (Refer to output load derating curve) | |||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | ||||||||
TEMP. COEFFICIENT | ±0.03%/℃(0 ~ 50℃) | ||||||||
OPERATING ALTITUDE Note.7 | 4000 meters | ||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||||||
SAFETY & EMC
(Note 4) |
SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved | |||||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 | ||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, heavy industry level, EAC TP TC 020 | ||||||||
OTHERS | MTBF | 3077.6K hrs min. Telcordia SR-332 (Bellcore) ; 563.0K hrs min. MIL-HDBK-217F (25℃) | |||||||
DIMENSION | PCB:101.6*50.8*29mm (L*W*H) ; with optional CASE:103.4*62*37mm (L*W*H) | ||||||||
PACKING | PCB: 0.15Kg; 96pcs/ 15.4 Kg/1.39CUFT ; with optional CASE: 0.3Kg; 45pcs/ 14.5Kg/0.63CUFT | ||||||||
NOTE |
|
Mechanical Specification
HS1 ,HS2 cannot be shorted.
- HS1 must have safety isolation distance with system case.
AC Input Connector (CN1): JST 83P-VH or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
1 | AC/N | JST VHR or equivalent |
JST SVH-21T-P1.1 or equivalent |
2 | No Pin | ||
3 | AC/L |
DC Output Connector (CN2) : JST B4P-VH or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
1,2 | +V | JST VHR or equivalent |
JST SVH-21T-P1.1 or equivalent |
3,4 | -V |
Grounding Required ;M1 and M2 are
Safety ground and should all be grounded
Block Diagram
Output Derating
AMBIENT TEMPERATURE ( ºC)
Static Characteristics
INPUT VOLTAGE (V) 60Hz
Documents / Resources
![]() |
MEAN WELL EPS-65 Series 65W Single Output Switching Power Supply [pdf] Owner's Manual EPS-65-20230313, EPS-65 Series, EPS-65 Series 65W Single Output Switching Power Supply, 65W Single Output Switching Power Supply, Single Output Switching Power Supply, Switching Power Supply, Power Supply |
![]() |
MEAN WELL EPS-65 Series 65W Single Output Switching Power Supply [pdf] Owner's Manual EPS-65 Series 65W Single Output Switching Power Supply, EPS-65 Series, 65W Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply, Supply |
![]() |
MEAN WELL EPS-65 Series 65W Single Output Switching Power Supply [pdf] Owner's Manual EPS-65 Series 65W Single Output Switching Power Supply, EPS-65 Series, 65W Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply |
![]() |
MEAN WELL EPS-65 Series 65W Single Output Switching Power Supply [pdf] Owner's Manual EPS-65 Series 65W Single Output Switching Power Supply, EPS-65 Series, 65W Single Output Switching Power Supply, Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply, Supply |