Fischer Channel FUS: Universal Mounting Channel System - Technical Data and Load Capacity

Channel FUS

The universal and complete mounting channel system for a wide range of applications

Overview & Features

The Channel FUS system is designed for secure, horizontal, and vertical installations, offering fast and efficient fixing of pipelines and supporting structures. It is suitable for use in dry interior areas.

Images

Visuals show different channel profiles and examples of 3D-frame constructions and solid frame constructions using the system.

Applications

  • Secure horizontal and vertical installations.
  • Fast and efficient fixing of pipelines and supporting structures.
  • For use in dry interior areas.

Advantages

  • Fire inspection report in line with MLAR/EN13501 guarantees independently tested functional safety.
  • Basic channel geometry allows usage of a complete extensive range of accessories.
  • Stamped serration in the channel provides a secure hold for sliding nuts, essential for high shear loads (e.g., vertical installation).
  • Different channel wall thicknesses allow for economical installation choices.
  • Scale on mounting channels simplifies cutting and positioning of fixtures during installation.

Properties

  • Material: pre-galvanised steel S250GD+Z275 (material no. 1.0242) acc. to DIN EN 10346.

Certificates

  • CE
  • ETA-21/0140
  • R 120
  • R 30 MLAR

Technical Data

The following tables detail the technical specifications for various Channel FUS profiles.

FUS Series Technical Data

Item Item no. ETA Fire test report Length [mm] Thickness S [mm] Sales unit [pcs]
FUS 21/1,5 - 2 m5451172,0001.51
FUS 21/1,5 - 3 m5451183,0001.51
FUS 21/1,5 - 6 m5451191)6,0001.51
FUS 21/2,0 - 2 m0403912,0002.01
FUS 21/2,0 - 3 m0976603,0002.01
FUS 21/2,0 - 6 m0976616,0002.01
FUS 21/2,5 - 2 m0928672,0002.51
FUS 21/2,5 - 3 m0773493,0002.51
FUS 21/2,5 - 6 m0775416,0002.51
FUS 41/1,5 - 2 m5451202,0001.51
FUS 41/1,5 - 3 m5451263,0001.51
FUS 41/1,5 - 6 m5451276,0001.51
FUS 41/2,0 - 2 m0403902,0002.01
FUS 41/2,0 - 3 m0976583,0002.01
FUS 41/2,0 - 6 m0976596,0002.01
FUS 41/2,5 - 2 m092295Yes2,0002.51
FUS 41/2,5 - 3 m077347Yes3,0002.51
FUS 41/2,5 - 6 m077537Yes6,0002.51
FUS 62/2,5 - 6 m504457Yes6,0002.51

1) Delivery time on request.

FUS D Series Technical Data

Item Item no. ETA Length [mm] Thickness S [mm] Sales unit [pcs]
FUS 21D/2,0 - 3 m5044583,0002.01
FUS 21D/2,0 - 6 m5355316,0002.01
FUS 41D/2,5 - 6 m5044596,0002.51
FUS 62D/2,5 - 6 m5044606,0002.51

Loads & Load Data

The following tables provide detailed load information for various Channel FUS profiles. Load curves are also available to illustrate load capacity under different conditions.

FUS Series Load Data

Item Item no. ETA Profile weight [kg/m] Channel cross section [cm²] Moment of inertia ly [cm⁴] Moment of inertia lz [cm⁴] Section modulus Wy [cm³] Section modulus Wz [cm³] Max. recommended static load for 1m length [kN] Max. recommended static load for 2m length [kN] Max. recommended static load for 3m length [kN] Sales unit [pcs]
FUS 21/1,5 - 2 m5451171.201.350.803.690.751.800.410.101
FUS 21/1,5 - 3 m5451181.201.350.803.690.751.800.410.101
FUS 21/1,5 - 6 m5451191)1.201.350.803.690.751.800.410.101
FUS 21/2,0 - 2 m0403911.441.720.974.660.892.270.490.120.051
FUS 21/2,0 - 3 m0976601.441.720.974.660.892.270.490.120.051
FUS 21/2,0 - 6 m0976611.441.720.974.660.892.270.490.120.051
FUS 21/2,5 - 2 m0928671.671.991.035.280.932.580.520.131
FUS 21/2,5 - 3 m0773491.671.991.035.280.932.580.520.130.061
FUS 21/2,5 - 6 m0775411.671.991.035.280.932.580.520.130.061
FUS 41/1,5 - 2 m5451201.801.954.266.032.072.941.560.540.241
FUS 41/1,5 - 3 m5451261.801.954.266.032.072.941.560.540.241
FUS 41/1,5 - 6 m5451271.801.954.266.032.072.941.560.540.241
FUS 41/2,0 - 2 m0403902.062.525.337.692.583.751.940.670.301
FUS 41/2,0 - 3 m0976582.062.525.337.692.583.751.940.670.301
FUS 41/2,0 - 6 m0976592.062.525.337.692.583.751.940.670.301
FUS 41/2,5 - 2 m092295Yes2.453.006.008.992.854.382.140.761
FUS 41/2,5 - 3 m077347Yes2.453.006.008.992.854.382.140.760.341
FUS 41/2,5 - 6 m077537Yes2.453.006.008.992.854.382.140.760.341

FUS D Series Load Data

Item Item no. ETA Profile weight [kg/m] Channel cross section [cm²] Moment of inertia ly [cm⁴] Moment of inertia lz [cm⁴] Section modulus Wy [cm³] Section modulus Wz [cm³] Max. recommended static load for 1m length [kN] Max. recommended static load for 2m length [kN] Max. recommended static load for 3m length [kN] Sales unit [pcs]
FUS 62/2,5 - 6 m5044573.274.0517.7012.905.626.294.222.100.991
FUS 21D/2,0 - 3 m5044582.873.445.499.312.614.541.960.690.311
FUS 21D/2,0 - 6 m5355312.873.445.499.312.614.541.960.690.311
FUS 41D/2,5 - 6 m5044594.896.0035.0117.908.768.786.583.281.961
FUS 62D/2,5 - 6 m5044606.558.09111.0025.8017.9012.5813.456.724.471

Load curves are provided for various channel types (e.g., FUS 21/1,5, FUS 21/2,0, FUS 21/2,5, FUS 41/1,5, FUS 41/2,0, FUS 41/2,5, FUS 62/2,5, FUS 21D/2,0, FUS 41D/2,5, FUS 62D/2,5). These curves illustrate the relationship between applied load (F in Newtons) and length (L in millimeters) for different load cases (Load case 1, Load case 2, Load case 3). The curves indicate the maximum permissible load for a given length under specific conditions, ensuring that permissible steel strain (e.g., 188 N/mm² or 160 N/mm²) and maximum deflection (L/200) are not exceeded. Fixings and screw fastenings must be calculated accordingly. The increased yield strength is calculated according to DIN EN 1993-1-3:2010-12, sec. 3.2.2.

Channel System FUS hdg (Hot-Dip Galvanized)

This section covers the hot-dip galvanized version of the Channel FUS system, offering enhanced corrosion protection for indoor and outdoor applications.

Applications (FUS hdg)

  • Creation of secure, horizontal and vertical installations.
  • Fast and efficient fixing of pipelines and supporting structures.
  • For indoor and outdoor application.

Properties (FUS hdg)

  • Material: steel S235JR (material no. 1.0037) acc. to DIN EN 1025.
  • Zinc plating: hot-dip galvanized.

Certificates (FUS hdg)

  • R 120
  • R 30 MLAR

Technical Data (FUS hdg)

Item Item no. Fire test report Length [mm] Thickness S [mm] Sales unit [pcs]
FUS 21/2.0 - 3 m hdg5376533,0002.01
FUS 41/2.0 - 3 m hdg5174263,0002.01
FUS 41/2.0 - 6 m hdg5376566,0002.01
FUS 41/2.5 - 6 m hdg537658Yes6,0002.51
FUS 62/2.5 - 3 m hdg517427Yes3,0002.51
FUS 62/2.5 - 6 m hdg517428Yes6,0002.51
FUS 21D/2.0 - 3 m hdg5376593,0002.01
FUS 21D/2.0 - 6 m hdg5376616,0002.01
FUS 41D/2.5 - 6 m hdg5376626,0002.51
FUS 62D/2.5 - 6 m hdg5376636,0002.51

Load Data (FUS hdg)

Item Item no. Profile weight [kg/m] Channel cross section [cm²] Moment of inertia ly [cm⁴] Moment of inertia lz [cm⁴] Section modulus Wy [cm³] Section modulus Wz [cm³] Max. recommended static load for 1m length [kN] Max. recommended static load for 2m length [kN] Max. recommended static load for 3m length [kN] Sales unit [pcs]
FUS 21/2.0 - 3 m hdg5376531.441.720.974.660.892.270.490.120.051
FUS 41/2.0 - 3 m hdg5174262.062.525.337.692.583.751.940.670.301
FUS 41/2.0 - 6 m hdg5376562.062.525.337.692.583.751.940.670.301
FUS 41/2.5 - 6 m hdg5376582.453.006.008.992.854.382.140.760.341
FUS 62/2.5 - 3 m hdg5174273.274.0517.7012.905.626.294.222.100.991
FUS 62/2.5 - 6 m hdg5174283.274.0517.7012.905.626.294.222.100.991
FUS 21D/2.0 - 3 m hdg5376592.873.445.499.312.614.541.960.690.311
FUS 21D/2.0 - 6 m hdg5376612.873.445.499.312.614.541.960.690.311
FUS 41D/2.5 - 6 m hdg5376624.896.0035.0117.908.768.786.583.281.961
FUS 62D/2.5 - 6 m hdg5376636.558.09111.0025.8017.9012.5813.456.724.471

Load curves for FUS hdg series are available, similar to the standard FUS series, detailing load capacity (F) against length (L) for different load cases. Permissible steel strain is noted as 160 N/mm² for these curves.

Channel FUS A2/A4 (Stainless Steel)

This section details the stainless steel variants of the Channel FUS system, offering superior corrosion resistance for demanding environments.

Applications (FUS A2/A4)

  • Secure horizontal and vertical installations.
  • Fast and efficient fixing of pipelines and supporting structures.
  • For indoor and outdoor application and in environments with high stress to components due to corrosion.
  • FUS A2: Not suitable for use in environments containing chlorine.

Properties (FUS A2/A4)

  • Material: stainless steel A2 (material no. 1.4301).
  • Material: stainless steel A4 (material no. 1.4404).

Technical Data (FUS A2/A4)

Item Item no. Fire test report Length [mm] Thickness S [mm] Sales unit [pcs]
FUS 21/2,0 A2 - 2 m5044662,0002.01
FUS 21/2,0 A2 - 6 m5427351)6,0002.01
FUS 41/2,0 A2 - 2 m5044682,0002.01
FUS 41/2,0 A2 - 6 m5427361)6,0002.01
FUS 41/2,5 A2 - 2 m504470Yes2,0002.51
FUS 41/2,5 A2 - 6 m5427371)Yes6,0002.51
FUS 21/2,0 A4 - 2 m5044722,0002.01
FUS 21/2,0 A4 - 6 m5427381)6,0002.01
FUS 41/2,0 A4 - 2 m5044742,0002.01
FUS 41/2,0 A4 - 6 m5427391)6,0002.01
FUS 41/2,5 A4 - 2 m504475Yes2,0002.51
FUS 41/2,5 A4 - 6 m5427401)Yes6,0002.51
FUS 41D/2,5 A4 - 6 m5626556,0002.51
FUS 62/2,5 A4 - 6 m557765Yes6,0002.51

1) Delivery time on request.

Load Data (FUS A2/A4)

Item Item no. Profile weight [kg/m] Channel cross section [cm²] Moment of inertia ly [cm⁴] Moment of inertia lz [cm⁴] Section modulus Wy [cm³] Section modulus Wz [cm³] Max. recommended static load for 1m length [kN] Max. recommended static load for 2m length [kN] Max. recommended static load for 3m length [kN] Sales unit [pcs]
FUS 41/2,0 A2 - 6 m5427361)2.062.525.337.692.583.751.580.640.281
FUS 41/2,5 A2 - 2 m5044702.453.006.008.992.854.381.740.721
FUS 41/2,5 A2 - 6 m5427371)2.453.006.008.992.854.381.740.720.321
FUS 21/2,0 A4 - 2 m5044721.441.720.974.660.892.270.470.121
FUS 21/2,0 A4 - 6 m5427381)1.441.720.974.660.892.270.470.120.051
FUS 41/2,0 A4 - 2 m5044742.062.525.337.692.583.751.650.641
FUS 41/2,0 A4 - 6 m5427391)2.062.525.337.692.583.751.650.640.281
FUS 41/2,5 A4 - 2 m5044752.453.006.008.992.854.381.820.721
FUS 41/2,5 A4 - 6 m5427401)2.453.006.008.992.854.381.820.720.321
FUS 41D/2,5 A4 - 6 m5626554.896.0035.0117.908.768.785.602.791.851
FUS 62/2,5 A4 - 6 m5577656.558.09111.0025.8017.9012.5811.455.723.801

Load curves for FUS A2/A4 series are available, similar to other series, detailing load capacity (F) against length (L) for different load cases. Permissible steel strain is noted as 160 N/mm² for these curves.

PDF preview unavailable. Download the PDF instead.

VKU CHANNEL-FUS EN Adobe PDF Library 17.0

Related Documents

Preview Fischer Cross Connector FVS II for FUS Channels - Installation Grid System
Detailed information on the Fischer Cross Connector FVS II, a component for creating flexible installation grids using FUS channels. Includes technical data, applications, advantages, and FUS channel specifications.
Preview Fischer Channel Nuts FCN Series: FCN, FCN 16 hdg, FCN 16 A4 - Technical Specifications
Detailed technical specifications, applications, advantages, properties, and load data for Fischer FCN, FCN 16 hdg, and FCN 16 A4 channel nuts. These components are designed for use with Fischer FUS channel systems, offering secure connections for various fixtures and pipe clamps in construction and industrial applications.
Preview Fischer FHBC HDG Beam Clamp for FUS Channels - Technical Specifications and Installation
Detailed information on the Fischer FHBC HDG beam clamp, designed for installing FUS channels on steel girders. Includes applications, advantages, properties, technical data, and installation guidelines.
Preview Fischer Saddle Flange SF Series: Technical Specifications and Applications
Comprehensive guide to Fischer's Saddle Flange SF, SF hdg, and SF L 41 A4 construction elements. Details applications, advantages, properties, and technical data for channel systems.
Preview Fischer FZF, FUF Flanges and FUF hdg Mounting Brackets: Technical Specifications
Detailed technical information on Fischer's FZF and FUF flanges and FUF hdg mounting brackets for channel systems, including applications, advantages, properties, and technical data.
Preview Fischer FMA-FUS System Connector for Massive Channel Systems
Detailed information on the Fischer FMA-FUS system connector, designed for creating multidimensional profile structures and supporting systems with FMP massive profiles and FUS mounting channels. Includes applications, advantages, properties, and technical specifications.
Preview Fischer Cantilever Arm FCA: Technical Specifications and Load Data
Comprehensive technical details, specifications, and load capacity charts for Fischer's Cantilever Arm FCA series, including FCA, FCA hdg, and FCA A4 models. Features include material properties, dimensions, fire resistance, and load case analysis for various installation scenarios.
Preview Fischer Channel System Brackets: FFF and FFF hdg Series
Discover Fischer's FFF and FFF hdg series of channel system brackets, essential construction elements for joining and strengthening channel structures. Details on applications, advantages, properties, and technical specifications for both electro zinc-plated and hot-dip galvanized options.