Ecotap Duo Wide Plus
A brand of Legrand
General Specifications
Reference Number | 65458064 |
Reference Number (Calibration Law) | 65458061 |
Dimensions H x W x D (mm) | 1400 x 490 x 240 |
Housing Material | Steel 3.7 mm |
Standard Color | Housing: Ral 6018 / Cover: Ral 9016 for 65458061, 65458064 |
Steel Treatment | Corrosion protection (KTL) and powder coating |
Weight (kg) | 90kg |
Number of Charging Points | 2 |
Socket | Type 2 |
Cable | Type 2 |
Cable | Type 2 |
Electrical Specifications
Power Output per Socket | 0 to 22 kW |
Operating Voltage (Ue) / Current (In A) for the Charger | Single-phase wiring, Phase + N 230V~ from 0 to 80A (specified at 20°C) Three-phase wiring, 3 Phases + N 400V~ from 0 to 80A (specified at 20°C) |
Operating Voltage (Ue) / Current (In A) per Charging Point | Single-phase wiring, Phase + N 230V~ from 0 to 32A (specified at 20°C) Three-phase wiring, 3 Phases + N 400V~ from 0 to 32A (specified at 20°C) |
Impulse Voltage (Uimp) | 4kV |
Insulation Voltage (Ui) | 230V single-phase, 500V three-phase |
Frequency (fn) | 50Hz/60Hz |
Rated Voltage | 1 Phase + N: 230V - 3 Phases + N: 400V |
Voltage Tolerance (V) Independent of Vehicle Requirements | 195V - 265V |
Integrated Protection System at Charging Station | Main fuse holder 50A |
Integrated Protection System per Charging Point | Fuse holder 32A Gg RCD 63A 30mA Type B |
Conditional Short-Circuit Current | 6000A IEC/EN 60898-1 10kA IEC/EN 60947-2 |
Permissible Thermal Load during Short Circuit | 16 000 A²s |
Connection to the Power Grid | Phase/Neutral, rigid cable, 2.5 to 35 mm², screw terminals H07 V R/U Earth, rigid cable, 2.5 to 35mm², screw terminals H07 V R/U |
Charging Type | Mode 3 charging station with a locking system for Mode 3 |
Vehicle Connector Socket Mode 3 | Type 2 3P+N (single-phase compatible) with control devices according to IEC 62191-1 and IEC 62196-2. Only use an approved plug with silver-plated contacts from the manufacturer. The use of extensions and adapters is prohibited. |
Vehicle Connector Socket Mode 2 (65293704) | Type E/F for domestic use 2P+E (16A-250V) according to local regulations. Use of extensions and adapters prohibited. |
Phase Rotation on Channel 2 (right side) | In the case of single-phase wiring (Ph+N) to the power source. Channel 2 cannot start charging until the phase rotation between the contactor and the socket is manually reversed. |
AC Meter | MID certified, Class B according to EN 50470-1, -3 |
Back-Office Protocol | OCPP 1.6 Json |
Positioning | GPS |
Ethernet Connectivity | RJ45 connection |
Environment
Operating Temperature | -25°C / +50°C |
Storage Temperature | -25°C / +80°C |
Relative Humidity | 0 to 90% without condensation |
Corrosivity Class | C4 according to IEC 9223 and IEC 12944 3C3/4C3 according to IEC 60721-3 |
Protection Class | IP 54 (IEC 60529), IK 10 (EN 62262) Plugged in or not |
Noise Level | < 40 dBA/1m |
Product | IEC 61851-1, IEC TS 61439-7 (AEVCS) |
Installation | Indoor or outdoor area, zone with restricted access, intended for use by normal persons (DBO), installation in a cabinet (wall mounting), pollution degree 3, TNS, TT, compatible earthing system. In case of an IT earthing system, this can be modified on site by adding an isolating transformer. |
Electrical Protection | Class 1 IEC 61140 |
Electromagnetic Compatibility
European Standards | Low Voltage Directive 2014 / 35EU / EMC Directive: 2014 / 30 / EU |
Type of Radio Technology | GSM 2G/3G/4G, GPRS, RFID |
Suitable Charging Cards | Mifare, Ntag and iCODE SLI Card |