Quick Reference Guide: Trane Foundation® 3 to 5 Tons Packaged Rooftop Units
Cooling and Gas/Electric
Model Information
Model Numbers: EDK, GDK
Used With: Packaged Cooling, Electric Heat (Optional), Packaged Cooling, Gas Heat
Date: July 2024
Document Identifier: RT-PRC114A-EN
Copyright and Trademarks
This document and the information within it are the property of Trane. Reproduction in whole or in part without written permission is prohibited. Trane reserves the right to revise this publication and make changes to its content without prior notification.
All trademarks referenced herein are the property of their respective owners.
List of Options
Note: Most factory-installed options are available for downflow air discharge units only. Verify with the ordering system for availability.
Table 1. List of Options
Factory Installed Options | Field Installed Options |
---|---|
Barometric Relief(a) (Downflow Low Leak Economizer Only) | Barometric Relief (Standard and Low Leak Economizer, Downflow and Horizontal Configuration) |
Complete Coat™ Microchannel Condenser Coil | Crankcase Heater |
Condensate Overflow Switch | Demand Control Ventilation with CO2 Sensor |
Economizer (Downflow)(a) | Economizer (Horizontal) |
Electric Heaters | Frostat™ |
Low Leak Economizer - Downflow | Low Ambient Kit |
Manual Outside Air Dampers | Low Leak Economizer - Horizontal |
Motorized Outside Air Dampers | LP Conversion Kit |
MERV-13 Filters | Powered Exhaust |
Oversized Motor | Remote Potentiometer |
Reference or Comparative Enthalpy Economizer | Roof Curb |
Stainless Steel Heat Exchanger with 10 Year Warranty | Thermostat |
Through-the-Base Electrical Access | Tool-less Hail Guard |
Through-the-Base Gas Piping | |
Unit Mounted Non-Fused Disconnect Switch(b) |
(a) Some field set up required.
(b) Must be ordered with Through-the-Base Electrical option.
Performance Data
Table 2. 3 to 5 Tons Packaged Rooftop Performance Data (Gas or Electric Heat)
Nominal Size (Ton) | Cooling Performance(a) | Gas Heating Performance | Other Information | |||
---|---|---|---|---|---|---|
Gross Cooling Capacity | AHRI Net Cooling Capacity | Nominal Airflow CFM/AHRI Rated CFM | Low Heat (Input/Output) - (Btu/h) | Medium Heat (Input/Output) - (Btu/h) | ||
3 | 38,000 | 36,600 | 1200/1050 | 72,000/57,600 | 100,000/80,000 | Net Weight (lbs) - Gas Heat: 524 (3T), 566 (4T), 586 (5T) Net Weight (lbs) - Electric Heat: 473 (3T), 516 (4T), 536 (5T) Filters - Type Furnished: Throwaway Number and Size Recommended: (4) 16x16x2 |
4 | 51,300 | 49,500 | 1600/1400 | 72,000/57,600 | 115,000/92,000 | |
5 | 59,500 | 57,500 | 2000/1600 | 72,000/57,600 | 115,000/92,000 |
(a) Cooling Performance is rated at 95°F ambient, 80°F entering dry bulb, 67°F entering wet bulb.
(b) EER and SEER are rated at AHRI conditions and calculated in accordance with AHRI Standard 210/240-2017. Airflow and net cooling capacity not shown.
(c) EER2 and SEER2 are rated at AHRI conditions and certified in accordance with AHRI Standard 210/240-2023.
Electrical Data
Table 3. Unit MCA and MOP Electrical Data (Standard Indoor Fan Motor - Cooling or Gas Heat)
Tons | Unit Operating Voltage Range | Standard Indoor Fan Motor | |
---|---|---|---|
Minimum Circuit Ampacity(a) | Maximum Fuse Size or Maximum Circuit Breaker | ||
3 | 208-230 | 23 | 30 |
460 | 11 | 15 | |
575 | 9 | 15 | |
4 | 208-230 | 23 | 35 |
460 | 11 | 15 | |
575 | 10 | 15 | |
5 | 208-230 | 28 | 40 |
460 | 13 | 15 | |
575 | 11 | 15 |
(a) Values do not include Power Exhaust accessory.
Indoor Fan Data
Table 4. Unit Indoor Fan Data
E/GDK | Volts | Standard (HP - RPM) | Oversized (HP - RPM) |
---|---|---|---|
036 | 208-230 | 1 - 1725 | 2 - 1725 |
460 | |||
575 | |||
048 | 208-230 | 1 - 1725 | 2 - 1725 |
460 | |||
575 | |||
060 | 208-230 | 1 - 1725 | 2 - 1725 |
460 | |||
575 |
Dimensional Data
Table 5. Unit Dimensional Data
3 to 5 Tons | |
---|---|
Unit Length UL | 76.814 in. |
Unit Width UW | 47.934 in. |
Unit Height UH | 42.004 in. |
Curb Length CL | 70.871 in. |
Curb Width CW | 41.983 in. |
Supply Length SL(a) | 21.060 in. |
Supply Width SW(a) | 14.000 in. |
Return Length RL(a) | 32.188 in. |
Return Width RW(a) | 14.430 in. |
(a) Dimensions are for curb openings and not duct inserts. Reference the product catalog for duct insert dimensions.
Diagram Description: Unit Dimensions
The diagram illustrates a packaged rooftop unit, showing key external dimensions labeled with abbreviations. The overall unit length is indicated by 'UL', the unit width by 'UW', and the unit height by 'UH'. The base or curb opening dimensions are shown as 'CL' (Curb Length) and 'CW' (Curb Width). Duct connection dimensions are also shown: 'SL' (Supply Length), 'SW' (Supply Width), 'RL' (Return Length), and 'RW' (Return Width).
Company Information and Policies
Trane and American Standard create comfortable, energy efficient indoor environments for commercial and residential applications. For more information, please visit trane.com or americanstandardair.com.
Trane and American Standard have a policy of continuous product and product data improvement and reserve the right to change design and specifications without notice. They are committed to using environmentally conscious print practices.
Document Identifier: RT-PRC114A-EN | Date: 12 Jul 2024 (NEW)
©2024