2 SINGLE PACKAGED GAS/ELECTRIC SYSTEMS PRODUCT DATA It's Hard to Stop a Trane. Single Packaged Convertible Gas/ Electric Systems Trane offers a complete family of packaged gas/electric heating and cooling
4ycc3036a1075ab Trane Parts Manual
22-1784-13 Product Data 4YCC3018 through 4YCC3060 Single Packaged Convertible Gas/Electric 13 SEER 1½ - 5 Ton, 40 - 120 MBTU R-410A © 2013 Trane 07/13 SINGLE PACKAGED GAS/ELECTRIC SYSTEMS PRODUCT DATA It's Hard to Stop a Trane. Single Packaged Convertible Gas/ Electric Systems Trane offers a complete family of packaged gas/electric heating and cooling systems, designed to give you the unbeatable combination of energy efficiency and lower operating costs. In warm weather, the package gas/electric system functions as an all-electric, high efficiency air conditioner. In cold weather, it operates as a natural gas or propane gas furnace, offering you the best of both energy worlds. Introducing the new TRANE Single Packaged Convertible Gas/Electric System. Single Packaged Convertible Gas/ Electric Systems are easy and versatile to install. Because cooling and heating functions are all contained in a single cabinet, a Trane single packaged convertible gas/electric system is easy to install and service. It can be flush mounted beside your home at ground level or placed on the roof for horizontal or downflow installation. When connected to an optional Trane thermostat control, and air distribution ducts, you have a highly efficient, total home comfort system. Single Packaged Convertible Gas/ Electric Systems are unmatched in quality and reliability. All major components on these products, including the compressor, have been designed and manufactured for maximum service. Every Climatuff® compressor is designed and manufactured to exacting specifications. Each design is life tested in extreme environments to ensure reliable and long lasting operation in normal applications. Each compressor has internal motor protection for added reliability. Single Packaged Convertible Gas/ Electric Systems provide better performance. Our single packaged cooling/heating units offer cooling/ heating efficiencies that are unmatched in the industry and provide you with a product far superior in performance than the competition. 2 MODELS 4YCC3018 - 4YCC3060 Contents Optional Equipment Listing...........................................4 General Data...................................................................5 Performance Data.........................................................11 Typical Field Wiring......................................................14 Typical Field Wiring......................................................15 Typical Field Wiring......................................................16 Optional Equipment.....................................................17 Dimensional Data and Weights...................................22 Mechanical Specifications...........................................28 3 SINGLE PACKAGED GAS/ELECTRIC SYSTEMS PRODUCT DATA Optional Equipment Listing OPTIONAL EQUIPMENT FOR PACKAGED UNITS (check mark [ ] indicates accessories included) Hinged Filter Access Door (4YCC3018-036) 8 ........................................................................................BAYACCDOR1A [ ] Hinged Filter Access Door (4YCC3042-060) 8 ........................................................................................BAYACCDOR2A [ ] Roof Curb Full Perimeter (4YCC3018-36A) 3 ...........................................................................................BAYCURB050A [ ] Roof Curb Full Perimeter (4YCC3042-60A) 3 ...........................................................................................BAYCURB051A [ ] Roof Curb Utility Extension Kit (BAYCURB050A).......................................................................................... BAYUTIL101A [ ] Roof Curb Utility Extension Kit (BAYCURB051A).......................................................................................... BAYUTIL102A [ ] 0-25% Manual Fresh Air Damper (4YCC3018-36A) 1............................................................................... BAYOSAH001A [ ] 0-25% Manual Fresh Air Damper (4YCC3042-60A) 1............................................................................... BAYOSAH002A [ ] Motorized Fresh Air Damper (4YCC3018-36A) 1...................................................................................... BAYDMPR101A [ ] Motorized Fresh Air Damper (4YCC3042-60A) 1...................................................................................... BAYDMPR102A [ ] 16" Round Duct Adapter (2 per box) (4YCC3018-36A) 6......................................................................... BAYSQRD001A [ ] 18" Round Duct Adapter (2 per box) (4YCC3018-60A) 6......................................................................... BAYSQRD002A [ ] 0-100% Mod Economizer w/Baro. Relief (4YCC3018-36A) 124 ........................................................... BAYECON101B [ ] 0-100% Mod. Economizer w/Baro. Relief (4YCC042-60A) 124.............................................................. BAYECON102B [ ] 0-100% Horizontal Economizer (4YCC3018-36A) 12 ............................................................................. BAYECON200A [ ] 0-100% Horizontal Economizer (4YCC3042-60A) 12 ............................................................................. BAYECON201A [ ] Enthalpy Control for Economizer (solid state).............................................................................................. BAYENTH001A [ ] Remote Potentiometer (All-BAYECON***A)....................................................................................................BAYSTAT023 [ ] 1"-2" Filter Frame (4YCC3018-36A) (20 x 25 filter not included) 1............................................................. BAYFLTR101B [ ] 1"-2" Filter Frame (4YCC3042-60A) (20 x 20,20X18 filter not included) 1.................................................. BAYFLTR201B [ ] LP Conversion Kit (All 40K, 120K Models) ..................................................................................................BAYLPKT100A [ ] LP Conversion Kit (All 64K, 96K Models) ....................................................................................................BAYLPKT101A [ ] LP Conversion Kit (All 75K Models).............................................................................................................BAYLPKT102A [ ] Head Pressure Control (Low Ambient Cool) (208/240v) Kit 5. ..................................................................BAYLOAM105A [ ] Quick Start Kit (4YCC3-A1)......................................................................................................................... BAYQSKT301A [ ] Crankcase Heater Recip (4YCC3018A1)(230v) 5......................................................................................BAYCCHT003A [ ] Crankcase Heater Scroll (4YCC3036,48,60A1/3)(230v) 5.........................................................................BAYCCHT202A [ ] Crankcase Heater (4YCC3036,48,60A4)(460v) 5......................................................................................BAYCCHT203A [ ] Adapter Curb 4YC*3018-036A to BAYCURB030,38....................................................................................BAYADAP050A [ ] Adapter Curb 4YC*3018-036A to BAYCURB033.........................................................................................BAYADAP051A [ ] Adapter Curb 4YC*3042-060A to BAYCURB030,38....................................................................................BAYADAP052A [ ] Adapter Curb 4YC*3042-060A to BAYCURB033.........................................................................................BAYADAP053A [ ] Adapter Curb 4YC*3042-060A to BAYCURB034.........................................................................................BAYADAP054A [ ] 12" Duct Shroud Covers Horizontal 4YCC3018-060A 7............................................................................BAYCOVR112A [ ] 18" Duct Shroud Covers Horizontal 4YCC3018-060A 7............................................................................BAYCOVR118A [ ] Extreme Condition Mounting Kit - All BAYCURB & BAYADAP....................................................................BAYEXMK001A [ ] Extreme Condition Mounting Kit - All BAYUTIL...........................................................................................BAYEXMK002B [ ] Extreme Condition Mounting Kit - All Slab Mounts......................................................................................BAYEXMK003A [ ] Lifting Lug Kit..................................................................................................................................................BAYLlFT002B [ ] NOTES: 1 Must use filter frame when economizer/fresh air kit is used. 2 Dry bulb control standard with economizer. 3 Ships knocked down. 4 Downflow only. 5 Low Ambient cooling requires crankcase heater (BAYCCHT----A). 6 It is the responsibility of the installing dealer to properly size the ductwork for each specific application. 7 BAYCOVR112,118A will not cover BAYSQRD002A applications 8 BAYACCDOR1A requires BAYFLTR101B & BAYACCDOR2A requires BAYFLTR201B. They are not backward compatible to BAYFLTR101/201A. 4 MODELS 4YCC3018 - 4YCC3060 General Data MODEL RATED Volts/PH/Hz Performance Cooling BTUH 1 Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr.) Sound Power Rating [dB(A)] 7 Performance Heating 2 Input BTUH (Natural Gas) 3 AFUE Temp. Rise -- Min/Max (°F) Orifice Qty / Drill Size (Natural Gas) POWER CONN.--V/PH/HZ Min. Brch. Cir. Ampacity Fuse Size -- Max. (amps) Fuse Size -- Recmd. (amps) COMPRESSOR Volts/Ph/Hz R.L. Amps -- L.R. Amps OUTDOOR COIL -- TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) INDOOR COIL -- TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN -- TYPE Dia. (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. 8 Motor -- HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps INDOOR FAN -- TYPE Dia x Width (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. 5 Motor -- HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps COMBUSTION FAN -- TYPE Drive/No. Speeds Motor -- HP/R.P.M. Volts/Ph/Hz FLA FILTER / FURNISHED Type Recommended Recmd. Face Area (sq. ft.) 6 REFRIGERANT Charge (lbs.) 4 GAS PIPE SIZE (in.) DIMENSIONS Crated (in.) WEIGHT Shipping (lbs.) / Net (lbs.) 4YCC3018A1040B 208-230/1/60 18000 670 1.685 11.0 / 13.0 74 40000 79.8 35 / 65 1 / #32 208-230/1/60 10.1 15 15 RECIPROCATING 208-230/1/60 6.4 / 38.6 SPINE-FIN 2 / 24 13.32 3/8 PLATE FIN 3 / 15 3.54 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23 DIRECT / 1 2540 1/12 / 810 208-230/1/60 0.54 / 0.95 CENTRIFUGAL 11 X 10 DIRECT / 2 SEE FAN PERF TABLE 1/8 / 825 200-230/1/60 1 / 1.63 CENTRIFUGAL DIRECT / 1 1/35 / 3480 208-230/1/60 0.26 NO THROWAWAY 4.0 R410A 6.10 1/2 H X W X L 45.86 / 44.5 / 52.03 471 / 375 4YCC3024B1064B 208-230/1/60 23000 725 2.09 11.0 / 13.0 76 64000 80 35 / 65 2 / #37 208-230/1/60 13.6 20 20 RECIPROCATING 208-230/1/60 8.3 / 57.8 SPINE-FIN 2 / 24 13.32 3/8 PLATE FIN 3 / 15 3.54 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23 DIRECT / 1 2530 1/12 / 810 230/1/60 0.90 / 0.95 CENTRIFUGAL 11 X 10 DIRECT / 2 SEE FAN PERF TABLE 1/4 / 825 200-230/1/60 1.4 / 2.8 CENTRIFUGAL DIRECT / 1 1/35 / 3480 208-230/1/60 0.26 NO THROWAWAY 4 R410A 6.00 1/2 H X W X L 45.86 / 44.5 / 52.03 444 / 348 4YCC3030C1075A 208-230/1/60 29000 970 2.5 11.0 / 13.0 70 75000 79.4 35 / 65 2 / #33 208-230/1/60 16.0 25 25 RECIPROCATING 200-230/1/60 9.0 / 73 SPINE-FIN 2 / 24 13.32 3/8 PLATE FIN 3 / 15 3.54 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23.4 DIRECT / 1 3220 1/6 / 830 208-230/1/60 1.0 / 1.7 CENTRIFUGAL 10 X 10 DIRECT / 2 SEE FAN PERF TABLE 1/2 / 1030 208-230/1/60 2.1 / 3.28 CENTRIFUGAL DIRECT / 1 1 / 35 / 3480 208-230/1/60 0.53 NO THROWAWAY 4.0 R410A 6.0 1/2 H X W X L 45.86 / 44.5 / 52.03 490 / 394 4YCC3036A1064B 208-230/1/60 35000 1200 3.284 11.0 / 13.0 75 64000 80.0 25 / 55 2 / #37 208-230/1/60 25.2 40 40 SCROLL 208-230/1/60 16.7 / 79 SPINE-FIN 2 / 24 13.32 3/8 PLATE FIN 4 / 15 3.54 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23 DIRECT / 1 3240 1/5 / 830 208-230/1/60 1.1 / 1.9 CENTRIFUGAL 10 X 10 DIRECT / 2 SEE FAN PERF TBL 1/2 / 1075 200-230/1/60 3.2 / 6.7 CENTRIFUGAL DIRECT / 1 1/35 / 3480 208-230/1/60 0.26 NO THROWAWAY 4.0 R410A 8.00 1/2 H X W X L 45.86 / 44.5 / 52.03 488 / 392 4YCC3036A1075B 208-230/1/60 35000 1200 3.284 11.0 / 13.0 75 75000 80.0 30 / 60 2 / #33 208-230/1/60 25.2 40 40 SCROLL 208-230/1/60 16.7 / 79 SPINE-FIN 2 / 24 13.32 3/8 PLATE FIN 4 / 15 3.54 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23 DIRECT / 1 3240 1/5 / 830 208-230/1/60 1.1 / 1.9 CENTRIFUGAL 10 X 10 DIRECT / 2 SEE FAN PERF TBL 1/2 / 1075 200-230/1/60 3.2 / 6.7 CENTRIFUGAL DIRECT / 1 1/35 / 3480 208-230/1/60 0.26 NO THROWAWAY 4.0 R410A 8.00 1/2 H X W X L 45.86 / 44.5 / 52.03 488 / 392 1 Rated in accordance with AHRI Standard 210/240. AHRI standard rating conditions are: 80 D.B. 67 W.B. entering air to indoor coil. 95 D.B. entering air to outdoor coil. 2 All models are certified to UL 1995. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation. 3 Convertible to LPG 4 This value is approximate. For more precise value, see Unit Nameplate. 5 Based on U.S. Government Standard Tests. 6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C. 0.05" W.C. 7 Sound Power values are not adjusted for AHRI270-95 tonal corrections. 8 Standard Air -- Dry Coil -- Outdoor. 5 SINGLE PACKAGED GAS/ELECTRIC SYSTEMS PRODUCT DATA General Data MODEL RATED Volts/PH/Hz Performance Cooling BTUH 1 Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr.) Sound Power Rating [dB(A)] 7 Performance Heating 2 Input BTUH (Natural Gas) 3 AFUE Temp. Rise -- Min/Max (°F) Orifice Qty / Drill Size (Natural Gas) POWER CONN.--V/PH/HZ Min. Brch. Cir. Ampacity Fuse Size -- Max. (amps) Fuse Size -- Recmd. (amps) COMPRESSOR Volts/Ph/Hz R.L. Amps -- L.R. Amps OUTDOOR COIL -- TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) INDOOR COIL -- TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN -- TYPE Dia. (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. 8 Motor -- HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps INDOOR FAN -- TYPE Dia x Width (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. 5 Motor -- HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps COMBUSTION FAN -- TYPE Drive/No. Speeds Motor -- HP/R.P.M. Volts/Ph/Hz FLA FILTER / FURNISHED Type Recommended Recmd. Face Area (sq. ft.) 6 REFRIGERANT Charge (lbs.) 4 GAS PIPE SIZE (in.) DIMENSIONS Crated (in.) WEIGHT Shipping (lbs.) / Net (lbs.) 4YCC3036A1096B 208-230/1/60 35000 1200 3.284 11.0 / 13.0 75 96000 80.0 40 / 70 3 / #37 208-230/1/60 25.2 40 40 SCROLL 208-230/1/60 16.7 / 79 SPINE-FIN 2 / 24 13.32 3/8 PLATE FIN 4 / 15 3.54 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23 DIRECT / 1 3240 1/5 / 830 208-230/1/60 1.1 / 1.9 CENTRIFUGAL 10 X 10 DIRECT / 2 SEE FAN PERF TBL 1/2 / 1075 200-230/1/60 3.2 / 6.7 CENTRIFUGAL DIRECT / 1 1/35 / 3480 208-230/1/60 0.26 NO THROWAWAY 4.0 R410A 8.00 1/2 H X W X L 45.86 / 44.5 / 52.03 493 / 397 4YCC3036A3064B 208-230/3/60 35000 1200 3.284 11.0 / 13.0 75 64000 80.0 25 / 55 2 / #37 208-230/3/60 17.2 25 25 SCROLL 208-230/3/60 10.4 / 73 SPINE-FIN 2 / 24 13.32 3/8 PLATE FIN 4 / 15 3.54 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23 DIRECT / 1 3240 1/5 / 830 208-230/1/60 1.1 / 1.9 CENTRIFUGAL 10 X 10 DIRECT / 2 SEE FAN PERF TABLE 1/2 / 1075 200-230/1/60 2.98 / 6.7 CENTRIFUGAL DIRECT / 1 1/35 / 3480 208-230/1/60 0.26 NO THROWAWAY 4.0 R410A 8.00 1/2 H X W X L 45.86 / 44.5 / 52.03 488 / 392 4YCC3036A3075B 208-230/3/60 35000 1200 3.284 11.0 / 13.0 75 75000 80.0 30 / 60 2 / #33 208-230/3/60 17.2 25 25 SCROLL 208-230/3/60 10.4 / 73 SPINE-FIN 2 / 24 13.32 3/8 PLATE FIN 4 / 15 3.54 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23 DIRECT / 1 3240 1/5 / 830 208-230/1/60 1.1 / 1.9 CENTRIFUGAL 10 X 10 DIRECT / 2 SEE FAN PERF TABLE 1/2 / 1075 200-230/1/60 2.98 / 6.7 CENTRIFUGAL DIRECT / 1 1/35 / 3480 208-230/1/60 0.26 NO THROWAWAY 4.0 R410A 8.00 1/2 H X W X L 45.86 / 44.5 / 52.03 488 / 392 4YCC3036A3096B 208-230/3/60 35000 1200 3.284 11.0 / 13.0 75 96000 80.0 40 / 70 3 / #37 208-230/3/60 17.2 25 25 SCROLL 208-230/3/60 10.4 / 73 SPINE-FIN 2 / 24 13.32 3/8 PLATE FIN 4 / 15 3.54 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23 DIRECT / 1 3240 1/5 / 830 208-230/1/60 1.1 / 1.9 CENTRIFUGAL 10 X 10 DIRECT / 2 SEE FAN PERF TABLE 1/2 / 1075 200-230/1/60 2.98 / 6.7 CENTRIFUGAL DIRECT / 1 1/35 / 3480 208-230/1/60 0.26 NO THROWAWAY 4.0 R410A 8.00 1/2 H X W X L 45.86 / 44.5 / 52.03 493 / 397 4YCC3036A4064B 460/3/60 35000 1200 3.284 11.0 / 13.0 75 64000 80.0 25 / 55 2 / #37 460/3/60 9.5 15 15 SCROLL 460/3/60 5.8 / 38 SPINE-FIN 2 / 24 13.32 3/8 PLATE FIN 4 / 15 3.54 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23 DIRECT / 1 3240 1/5 / 830 460/1/60 0.6 / 1.3 CENTRIFUGAL 10 X 10 DIRECT / 2 SEE FAN PERF TABLE 1/2 / 1075 460/1/60 1.7 / 3.12 CENTRIFUGAL DIRECT / 1 1/35 / 3480 460/1/60 0.25 NO THROWAWAY 4.0 R410A 8.00 1/2 H X W X L 45.86 / 44.5 / 52.03 488 / 392 1 Rated in accordance with AHRI Standard 210/240. AHRI standard rating conditions are: 80 D.B. 67 W.B. entering air to indoor coil. 95 D.B. entering air to outdoor coil. 2 All models are certified to UL 1995. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation. 3 Convertible to LPG 4 This value is approximate. For more precise value, see Unit Nameplate. 5 Based on U.S. Government Standard Tests. 6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C. 0.05" W.C. 7 Sound Power values are not adjusted for AHRI270-95 tonal corrections. 8 Standard Air -- Dry Coil -- Outdoor. 6 MODELS 4YCC3018 - 4YCC3060 General Data MODEL RATED Volts/PH/Hz Performance Cooling BTUH 1 Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr.) Sound Power Rating [dB(A)] 7 Performance Heating 2 Input BTUH (Natural Gas) 3 AFUE Temp. Rise -- Min/Max (°F) Orifice Qty / Drill Size (Natural Gas) POWER CONN.--V/PH/HZ Min. Brch. Cir. Ampacity Fuse Size -- Max. (amps) Fuse Size -- Recmd. (amps) COMPRESSOR Volts/Ph/Hz R.L. Amps -- L.R. Amps OUTDOOR COIL -- TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) INDOOR COIL -- TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN -- TYPE Dia. (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. 8 Motor -- HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps INDOOR FAN -- TYPE Dia x Width (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. 5 Motor -- HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps COMBUSTION FAN -- TYPE Drive/No. Speeds Motor -- HP/R.P.M. Volts/Ph/Hz FLA FILTER / FURNISHED Type Recommended Recmd. Face Area (sq. ft.) 6 REFRIGERANT Charge (lbs.) 4 GAS PIPE SIZE (in.) DIMENSIONS Crated (in.) WEIGHT Shipping (lbs.) / Net (lbs.) 4YCC3036A4075B 460/3/60 35000 1200 3.284 11.0 / 13.0 75 75000 80.0 30 / 60 2 / #33 460/3/60 9.5 15 15 SCROLL 460/3/60 5.8 / 38 SPINE-FIN 2 / 24 13.32 3/8 PLATE FIN 4 / 15 3.54 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23 DIRECT / 1 3240 1/5 / 830 460/1/60 0.6 / 1.3 CENTRIFUGAL 10 X 10 DIRECT / 2 SEE FAN PERF TABLE 1/2 / 1075 460/1/60 1.7 / 3.12 CENTRIFUGAL DIRECT / 1 1/35 / 3480 460/1/60 0.25 NO THROWAWAY 4.0 R410A 8.00 1/2 H X W X L 45.86 / 44.5 / 52.03 488 / 392 4YCC3036A4096B 460/3/60 35000 1200 3.284 11.0 / 13.0 75 96000 80.0 40 / 70 3 / #37 460/3/60 9.50 15 15 SCROLL 460/3/60 5.8 / 38 SPINE-FIN 2 / 24 13.32 3/8 PLATE FIN 4 / 15 3.54 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23 DIRECT / 1 3240 1/5 / 830 460/1/60 0.6 / 1.3 CENTRIFUGAL 10 X 10 DIRECT / 2 SEE FAN PERF TABLE 1/2 / 1075 460/1/60 1.7 / 3.12 CENTRIFUGAL DIRECT / 1 1/35 / 3480 460/1/60 0.25 NO THROWAWAY 4.0 R410A 8.00 1/2 H X W X L 45.86 / 44.5 / 52.03 493 / 397 4YCC3042B1096A 208-230/1/60 41500 1450 3.77 11.0 / 13.0 74 96000 80 35 / 65 3 / #37 208-230/1/60 26.3 40 40 SCROLL 208-230/1/60 17.9 / 112 SPINE-FIN 2 / 24 18.01 3/8 PLATE FIN 3 / 15 5 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 28.2 DIRECT / 1 4400 1/4 / 825 208-230/1/60 1.5 / 3.07 CENTRIFUGAL 11 X 10 DIRECT / 2 SEE FAN PERF TABLE 1/2 / 1075 208-230/1/60 2.1 / 3.5 CENTRIFUGAL DIRECT / 1 1/35 / 3480 208-230/1/60 0.53 NO THROWAWAY 5.3 R410A 7.51 1/2 H X W X L 47.86 / 47.4 / 61.75 643 / 515 4YCC3048A1075B 208-230/1/60 46500 1600 4.252 11.0 / 13.0 80 75000 80.0 20 / 50 2 / #33 208-230/1/60 33.1 50 50 SCROLL 208-230/1/60 21.8 / 117 SPINE-FIN 2 / 24 18.01 3/8 PLATE FIN 3 / 15 5 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 27.6 DIRECT / 1 4390 1/4 / 825 208-230/1/60 1.4 / 3.5 CENTRIFUGAL 10 X 10 DIRECT / 2 SEE FAN PERF TABLE 3/4 / 1075 200-230/1/60 4.4 / 8.8 CENTRIFUGAL DIRECT / 1 1/35 / 3480 208-230/1/60 0.26 NO THROWAWAY 5.3 R410A 8.50 1/2 H X W X L 47.86 / 47.4 / 61.75 645 / 517 4YCC3048A1096B 208-230/1/60 46500 1600 4.252 11.0 / 13.0 80 96000 80.0 30 / 60 3 / #37 208-230/1/60 33.1 50 50 SCROLL 208-230/1/60 21.8 / 117 SPINE-FIN 2 / 24 18.01 3/8 PLATE FIN 3 / 15 5 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 27.6 DIRECT / 1 4390 1/4 / 825 208-230/1/60 1.4 / 3.5 CENTRIFUGAL 10 X 10 DIRECT / 2 SEE FAN PERF TABLE 3/4 / 1075 200-230/1/60 4.4 / 8.8 CENTRIFUGAL DIRECT / 1 1/35 / 3480 208-230/1/60 0.26 NO THROWAWAY 5.3 R410A 8.50 1/2 H X W X L 47.86 / 47.4 / 61.75 653 / 525 1 Rated in accordance with AHRI Standard 210/240. AHRI standard rating conditions are: 80 D.B. 67 W.B. entering air to indoor coil. 95 D.B. entering air to outdoor coil. 2 All models are certified to UL 1995. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation. 3 Convertible to LPG 4 This value is approximate. For more precise value, see Unit Nameplate. 5 Based on U.S. Government Standard Tests. 6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C. 0.05" W.C. 7 Sound Power values are not adjusted for AHRI270-95 tonal corrections. 8 Standard Air -- Dry Coil -- Outdoor. 7 SINGLE PACKAGED GAS/ELECTRIC SYSTEMS PRODUCT DATA General Data MODEL RATED Volts/PH/Hz Performance Cooling BTUH 1 Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr.) Sound Power Rating [dB(A)] 7 Performance Heating 2 Input BTUH (Natural Gas) 3 AFUE Temp. Rise -- Min/Max (°F) Orifice Qty / Drill Size (Natural Gas) POWER CONN.--V/PH/HZ Min. Brch. Cir. Ampacity Fuse Size -- Max. (amps) Fuse Size -- Recmd. (amps) COMPRESSOR Volts/Ph/Hz R.L. Amps -- L.R. Amps OUTDOOR COIL -- TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) INDOOR COIL -- TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN -- TYPE Dia. (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. 8 Motor -- HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps INDOOR FAN -- TYPE Dia x Width (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. 5 Motor -- HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps COMBUSTION FAN -- TYPE Drive/No. Speeds Motor -- HP/R.P.M. Volts/Ph/Hz FLA FILTER / FURNISHED Type Recommended Recmd. Face Area (sq. ft.) 6 REFRIGERANT Charge (lbs.) 4 GAS PIPE SIZE (in.) DIMENSIONS Crated (in.) WEIGHT Shipping (lbs.) / Net (lbs.) 4YCC3048A1120B 208-230/1/60 46500 1600 4.252 11.0 / 13.0 80 120000 80.0 40 / 70 3 / #32 208-230/1/60 33.1 50 50 SCROLL 208-230/1/60 21.8 / 117 SPINE-FIN 2 / 24 18.01 3/8 PLATE FIN 3 / 15 5 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 27.6 DIRECT / 1 4390 1/4 / 825 208-230/1/60 1.4 / 3.5 CENTRIFUGAL 10 X 10 DIRECT / 2 SEE FAN PERF TABLE 3/4 / 1075 200-230/1/60 4.4 / 8.8 CENTRIFUGAL DIRECT / 1 1/35 / 3480 208-230/1/60 0.26 NO THROWAWAY 5.3 R410A 8.50 1/2 H X W X L 47.86 / 47.4 / 61.75 659 / 531 4YCC3048A3075B 208-230/3/60 46500 1600 4.252 11.0 / 13.0 80 75000 80.0 20 / 50 2 / #33 208-230/3/60 22.9 35 35 SCROLL 208-230/3/60 13.7 / 83.1 SPINE-FIN 2 / 24 18.01 3/8 PLATE FIN 3 / 15 5 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 27.6 DIRECT / 1 4390 1/4 / 825 208-230/1/60 1.4 / 3.5 CENTRIFUGAL 10 X 10 DIRECT / 2 SEE FAN PERF TABLE 3/4 / 1075 200-230/1/60 4.4 / 8.8 CENTRIFUGAL DIRECT / 1 1/35 / 3480 208-230/1/60 0.26 NO THROWAWAY 5.3 R410A 8.50 1/2 H X W X L 47.86 / 47.4 / 61.75 645 / 517 4YCC3048A3096B 208-230/3/60 46500 1600 4.252 11.0 / 13.0 80 96000 80.0 30 / 60 3 / #37 208-230/3/60 22.9 35 35 SCROLL 208-230/3/60 13.7 / 83.1 SPINE-FIN 2 / 24 18.01 3/8 PLATE FIN 3 / 15 5 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 27.6 DIRECT / 1 4390 1/4 / 825 208-230/1/60 1.4 / 3.5 CENTRIFUGAL 10 X 10 DIRECT / 2 SEE FAN PERF TABLE 3/4 / 1075 200-230/1/60 4.4 / 8.8 CENTRIFUGAL DIRECT / 1 1/35 / 3480 208-230/1/60 0.26 NO THROWAWAY 5.3 R410A 8.50 1/2 H X W X L 47.86 / 47.4 / 61.75 653 / 525 4YCC3048A3120B 208-230/3/60 46500 1600 4.252 11.0 / 13.0 80 120000 80.0 40 / 70 3 / #32 208-230/3/60 22.9 35 35 SCROLL 208-230/3/60 13.7 / 83.1 SPINE-FIN 2 / 24 18.01 3/8 PLATE FIN 3 / 15 5 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 27.6 DIRECT / 1 4390 1/4 / 825 208-230/1/60 1.4 / 3.5 CENTRIFUGAL 10 X 10 DIRECT / 2 SEE FAN PERF TABLE 3/4 / 1075 200-230/1/60 4.4 / 8.8 CENTRIFUGAL DIRECT / 1 1/35 / 3480 208-230/1/60 0.26 NO THROWAWAY 5.3 R410A 8.50 1/2 H X W X L 47.86 / 47.4 / 61.75 659 / 531 4YCC3048A4075B 460/3/60 46500 1600 4.252 11.0 / 13.0 80 75000 80.0 20 / 50 2 / #33 460/3/60 10.7 15 15 SCROLL 460/3/60 6.2 / 41 SPINE-FIN 2 / 24 18.01 3/8 PLATE FIN 3 / 15 5 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 27.6 DIRECT / 1 4390 1/4 / 825 460/1/60 0.74 / 1.6 CENTRIFUGAL 10 X 10 DIRECT / 2 SEE FAN PERF TABLE 3/4 / 1080 460/1/60 2.2 / 4.36 CENTRIFUGAL DIRECT / 1 1/35 / 3480 460/1/60 0.25 NO THROWAWAY 5.3 R410A 8.50 1/2 H X W X L 47.86 / 47.4 / 61.75 645 / 517 1 Rated in accordance with AHRI Standard 210/240. AHRI standard rating conditions are: 80 D.B. 67 W.B. entering air to indoor coil. 95 D.B. entering air to outdoor coil. 2 All models are certified to UL 1995. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation. 3 Convertible to LPG 4 This value is approximate. For more precise value, see Unit Nameplate. 5 Based on U.S. Government Standard Tests. 6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C. 0.05" W.C. 7 Sound Power values are not adjusted for AHRI270-95 tonal corrections. 8 Standard Air -- Dry Coil -- Outdoor. 8 MODELS 4YCC3018 - 4YCC3060 General Data MODEL RATED Volts/PH/Hz Performance Cooling BTUH 1 Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr.) Sound Power Rating [dB(A)] 7 Performance Heating 2 Input BTUH (Natural Gas) 3 AFUE Temp. Rise -- Min/Max (°F) Orifice Qty / Drill Size (Natural Gas) POWER CONN.--V/PH/HZ Min. Brch. Cir. Ampacity Fuse Size -- Max. (amps) Fuse Size -- Recmd. (amps) COMPRESSOR Volts/Ph/Hz R.L. Amps -- L.R. Amps OUTDOOR COIL -- TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) INDOOR COIL -- TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN -- TYPE Dia. (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. 8 Motor -- HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps INDOOR FAN -- TYPE Dia x Width (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. 5 Motor -- HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps COMBUSTION FAN -- TYPE Drive/No. Speeds Motor -- HP/R.P.M. Volts/Ph/Hz FLA FILTER / FURNISHED Type Recommended Recmd. Face Area (sq. ft.) 6 REFRIGERANT Charge (lbs.) 4 GAS PIPE SIZE (in.) DIMENSIONS Crated (in.) WEIGHT Shipping (lbs.) / Net (lbs.) 4YCC3048A4096B 460/3/60 46500 1600 4.252 11.0 / 13.0 80 96000 80.0 30 / 60 3 / #37 460/3/60 10.7 15 15 SCROLL 460/3/60 6.2 / 41 SPINE-FIN 2 / 24 18.01 3/8 PLATE FIN 3 / 15 5 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 27.6 DIRECT / 1 4390 1/4 / 825 460/1/60 0.74 / 1.6 CENTRIFUGAL 10 X 10 DIRECT / 2 SEE FAN PERF TABLE 3/4 / 1080 460/1/60 2.2 / 4.36 CENTRIFUGAL DIRECT / 1 1/35 / 3480 460/1/60 0.25 NO THROWAWAY 5.3 R410A 8.50 1/2 H X W X L 47.86 / 47.4 / 61.75 653 / 525 4YCC3048A4120B 460/3/60 46500 1600 4.252 11.0 / 13.0 80 120000 80.0 40 / 70 3 / #32 460/3/60 10.7 15 15 SCROLL 460/3/60 6.2 / 41 SPINE-FIN 2 / 24 18.01 3/8 PLATE FIN 3 / 15 5 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 27.6 DIRECT / 1 4390 1/4 / 825 460/1/60 0.74 / 1.6 CENTRIFUGAL 10 X 10 DIRECT / 2 SEE FAN PERF TABLE 3/4 / 1080 460/1/60 2.2 / 4.36 CENTRIFUGAL DIRECT / 1 1/35 / 3480 460/1/60 0.25 NO THROWAWAY 5.3 R410A 8.50 1/2 H X W X L 47.86 / 47.4 / 61.75 659 / 531 4YCC3060A1096B 208-230/1/60 58000 1800 5.478 10.95 / 13.0 79 96000 80.0 25 / 55 3 / #37 208-230/1/60 41.9 60 60 SCROLL 208-230/1/60 26.3 / 134 SPINE-FIN 2 / 24 20.54 3/8 PLATE FIN 4 / 15 5 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 27.6 DIRECT / 1 4390 1/4 / 825 208-230/1/60 1.4 / 3.5 CENTRIFUGAL 11 X 10 DIRECT / 3 SEE FAN PERF TABLE 1 / 1075 208-230/1/60 7.6 / 7.4 CENTRIFUGAL DIRECT / 1 1/35 / 3480 208-230/1/60 0.26 NO THROWAWAY 5.3 R410A 10.30 1/2 H X W X L 49.86 / 47.4 / 61.75 678 / 550 4YCC3060A1120B 208-230/1/60 58000 1800 5.478 10.95 / 13.0 79 120000 80.0 30 / 60 3 / #32 208-230/1/60 41.9 60 60 SCROLL 208-230/1/60 26.3 / 134 SPINE-FIN 2 / 24 20.54 3/8 PLATE FIN 4 / 15 5 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 27.6 DIRECT / 1 4390 1/4 / 825 208-230/1/60 1.4 / 3.5 CENTRIFUGAL 11 X 10 DIRECT / 3 SEE FAN PERF TABLE 1 / 1075 208-230/1/60 7.6 / 7.4 CENTRIFUGAL DIRECT / 1 1/35 / 3480 208-230/1/60 0.26 NO THROWAWAY 5.3 R410A 10.30 1/2 H X W X L 49.86 / 47.4 / 61.75 684 / 556 4YCC3060A3096B 208-230/3/60 58000 1800 5.478 10.95 / 13.0 79 96000 80.0 25 / 55 3 / #37 208-230/3/60 28.6 40 40 SCROLL 208-230/3/60 15.6 / 110 SPINE-FIN 2 / 24 20.54 3/8 PLATE FIN 4 / 15 5 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 27.6 DIRECT / 1 4390 1/4 / 825 208-230/1/60 1.4 / 3.5 CENTRIFUGAL 11 X 10 DIRECT / 3 SEE FAN PERF TABLE 1 / 1075 208-230/1/60 7.6 / 7.4 CENTRIFUGAL DIRECT / 1 1/35 / 3480 208-230/1/60 0.26 NO THROWAWAY 5.3 R410A 10.30 1/2 H X W X L 49.86 / 47.4 / 61.75 678 / 550 1 Rated in accordance with AHRI Standard 210/240. AHRI standard rating conditions are: 80 D.B. 67 W.B. entering air to indoor coil. 95 D.B. entering air to outdoor coil. 2 All models are certified to UL 1995. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation. 3 Convertible to LPG 4 This value is approximate. For more precise value, see Unit Nameplate. 5 Based on U.S. Government Standard Tests. 6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C. 0.05" W.C. 7 Sound Power values are not adjusted for AHRI270-95 tonal corrections. 8 Standard Air -- Dry Coil -- Outdoor. 9 SINGLE PACKAGED GAS/ELECTRIC SYSTEMS PRODUCT DATA General Data MODEL RATED Volts/PH/Hz Performance Cooling BTUH 1 Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr.) Sound Power Rating [dB(A)] 7 Performance Heating 2 Input BTUH (Natural Gas) 3 AFUE Temp. Rise -- Min/Max (°F) Orifice Qty / Drill Size (Natural Gas) POWER CONN.--V/PH/HZ Min. Brch. Cir. Ampacity Fuse Size -- Max. (amps) Fuse Size -- Recmd. (amps) COMPRESSOR Volts/Ph/Hz R.L. Amps -- L.R. Amps OUTDOOR COIL -- TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) INDOOR COIL -- TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN -- TYPE Dia. (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. 8 Motor -- HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps INDOOR FAN -- TYPE Dia x Width (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. 5 Motor -- HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps COMBUSTION FAN -- TYPE Drive/No. Speeds Motor -- HP/R.P.M. Volts/Ph/Hz FLA FILTER / FURNISHED Type Recommended Recmd. Face Area (sq. ft.) 6 REFRIGERANT Charge (lbs.) 4 GAS PIPE SIZE (in.) DIMENSIONS Crated (in.) WEIGHT Shipping (lbs.) / Net (lbs.) 4YCC3060A3120B 208-230/3/60 58000 1800 5.478 10.95 / 13.0 79 120000 80.0 30 / 60 3 / #32 208-230/3/60 28.6 40 40 SCROLL 208-230/3/60 15.6 / 110 SPINE-FIN 2 / 24 20.54 3/8 PLATE FIN 4 / 15 5 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 27.6 DIRECT / 1 4390 1/4 / 825 208-230/1/60 1.4 / 3.5 CENTRIFUGAL 11 X 10 DIRECT / 3 SEE FAN PERF TABLE 1 / 1075 208-230/1/60 7.6 / 7.4 CENTRIFUGAL DIRECT / 1 1/35 / 3480 208-230/1/60 0.26 NO THROWAWAY 5.3 R410A 10.30 1/2 H X W X L 49.86 / 47.4 / 61.75 684 / 556 4YCC3060A4096B 460/3/60 58000 1800 5.478 10.95 / 13.0 79 96000 80.0 25 / 55 3 / #37 460/3/60 18.0 25 25 SCROLL 460/3/60 7.8 / 52 SPINE-FIN 2 / 24 20.54 3/8 PLATE FIN 4 / 15 5 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 27.6 DIRECT / 1 4390 1/4 / 825 208-230/1/60 0.74 / 1.6 CENTRIFUGAL 11 X 10 DIRECT / 3 SEE FAN PERF TABLE 1 / 1075 208-230/1/60 7.6 / 7.4 CENTRIFUGAL DIRECT / 1 1/35 / 3480 460/1/60 0.25 NO THROWAWAY 5.3 R410A 10.30 1/2 H X W X L 49.86 / 47.4 / 61.75 678 / 550 4YCC3060A4120B 460/3/60 58000 1800 5.478 10.95 / 13.0 79 120000 80.0 30 / 60 3 / #32 460/3/60 18.0 25 25 SCROLL 460/3/60 7.8 / 52 SPINE-FIN 2 / 24 20.54 3/8 PLATE FIN 4 / 15 5 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 27.6 DIRECT / 1 4390 1/4 / 825 208-230/1/60 0.74 / 1.6 CENTRIFUGAL 11 X 10 DIRECT / 3 SEE FAN PERF TABLE 1 / 1075 208-230/1/60 7.6 / 7.4 CENTRIFUGAL DIRECT / 1 1/35 / 3480 460/1/60 0.25 NO THROWAWAY 5.3 R410A 10.30 1/2 H X W X L 49.86 / 47.4 / 61.75 684 / 556 1 Rated in accordance with AHRI Standard 210/240. AHRI standard rating conditions are: 80 D.B. 67 W.B. entering air to indoor coil. 95 D.B. entering air to outdoor coil. 2 All models are certified to UL 1995. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation. 3 Convertible to LPG 4 This value is approximate. For more precise value, see Unit Nameplate. 5 Based on U.S. Government Standard Tests. 6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C. 0.05" W.C. 7 Sound Power values are not adjusted for AHRI270-95 tonal corrections. 8 Standard Air -- Dry Coil -- Outdoor. 10 MODELS 4YCC3018 - 4YCC3060 Performance Data Indoor Fan Performance 4YC*3018 Horizontal Airflow 4YC*3018-HOR EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 LOW WATTS 149 147 142 138 - - - - - - - CFM 688 631 547 461 - - - - - - - HIGH WATTS - 269 259 247 233 220 208 - - - - CFM - 1049 981 897 794 674 549 - - - - Down Airflow 4YC*3018-DOWN EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 LOW WATTS 148 143 141 137 - - - - - - - CFM 668 593 515 440 - - - - - - - HIGH WATTS 275 264 254 244 232 218 205 - - - - CFM 1066 989 927 852 750 626 502 - - - - Indoor Fan Performance 4YC*3024 Horizontal Airflow 4YC*3024 - HOR EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 LOW WATTS 215 212 205 195 186 - - - - - - CFM 831 796 743 677 602 - - - - - - HIGH WATTS - - 358 345 327 302 277 266 - - - CFM - - 1239 1165 1056 898 720 593 - - - Down Airflow 4YC*3024 - DOWN EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 LOW WATTS 215 208 201 193 183 - - - - - - CFM 812 766 721 662 583 - - - - - - HIGH WATTS 377 367 351 331 310 291 274 262 - - - CFM 1331 1274 1193 1090 966 829 686 547 - - - Indoor Fan Performance 4YC*3030 Horizontal Airflow 4YC*3030 - HOR EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 LOW WATTS 358 345 339 331 319 301 - - - - - CFM 1218 1149 1103 1052 979 879 - - - - - HIGH WATTS - - - 467 450 434 415 390 - - - CFM - - - 1330 1248 1158 1048 901 - - - Down Airflow 4YC*3030 - DOWN EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 LOW WATTS 358 345 336 325 312 297 - - - - - CFM 1176 1136 1080 1012 933 839 - - - - - HIGH WATTS - - - 463 443 424 404 381 - - - CFM - - - 1296 1201 1093 969 822 - - - 11 SINGLE PACKAGED GAS/ELECTRIC SYSTEMS PRODUCT DATA Performance Data Indoor Fan Performance 4YC*3036 Horizontal Airflow 4YC*3036-HOR EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 LOW WATTS 470 448 434 420 402 378 351 - - - - CFM 1332 1292 1240 1177 1100 1007 896 - - - - HIGH WATTS - 670 651 634 616 595 569 536 498 - - CFM - 1542 1472 1426 1364 1267 1135 989 869 - - Down Airflow 4YC*3036-DOWN EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 LOW WATTS 460 445 431 416 400 381 358 - - - - CFM 1267 1257 1198 1124 1050 966 843 - - - - HIGH WATTS - 713 694 676 657 636 612 588 - - - CFM - 1584 1502 1420 1327 1221 1100 970 - - - Indoor Fan Performance 4YC*3042 Horizontal Airflow 4YC*3042 - HOR EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 LOW WATTS 543 540 532 522 511 499 484 461 - - - CFM 1490 1490 1471 1444 1415 1382 1339 1272 - - - HIGH WATTS - 633 624 602 580 562 547 525 480 - - CFM - 1715 1695 1640 1584 1539 1497 1428 1284 - - Down Airflow 4YC*30424 - DOWN EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 LOW WATTS 548 523 517 512 497 472 446 440 - - - CFM 1525 1467 1449 1429 1386 1320 1250 1215 - - - HIGH WATTS - 611 597 583 567 549 529 507 482 - - CFM - 1680 1646 1606 1559 1505 1441 1366 1277 - - Indoor Fan Performance 4YC*3048 Horizontal Airflow 4YC*3048 -HOR EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 LOW WATTS 687 668 649 628 606 581 551 516 - - - CFM 1863 1810 1760 1708 1648 1577 1493 1391 - - - HIGH WATTS - 935 921 886 851 825 803 773 708 - - CFM - 2159 2110 2017 1919 1833 1753 1652 1482 - - Down Airflow 4YC*3048 -DOWN EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 LOW WATTS 671 650 632 614 594 571 543 512 - - - CFM 1839 1795 1741 1682 1622 1554 1472 1362 - - - HIGH WATTS - 901 879 857 835 813 787 754 708 - - CFM - 2080 2013 1943 1872 1797 1709 1590 1418 - - 12 MODELS 4YCC3018 - 4YCC3060 Performance Data indoor Fan Performance 4YC*3060 Horizontal Airflow 4YC*3060-HOR EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 LOW WATTS 500 498 513 532 548 559 568 582 - - - CFM 1884 1873 1842 1806 1772 1743 1716 1685 - - - MEDIUM WATTS 657 650 659 677 696 714 729 741 752 767 CFM 2052 2056 2035 2002 1967 1935 1907 1878 1841 1783 - HIGH WATTS - 780 790 802 816 831 846 860 870 874 - CFM - 2184 2151 2128 2103 2069 2030 1994 1979 2013 - Down Airflow 4YC*3060-DOWN EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 LOW WATTS 499 511 525 540 553 565 578 593 - - - CFM 1873 1850 1816 1779 1742 1709 1676 1639 - - - MEDIUM WATTS 661 670 684 698 712 725 737 749 764 785 CFM 2071 2034 2001 1970 1941 1912 1881 1844 1799 1740 - HIGH WATTS - 800 819 826 834 848 866 875 859 790 - CFM - 2158 2123 2092 2063 2034 2000 1961 1911 1849 - AFUE Ratings 4YCC AFUE RATINGS All 4YCC3018A through 4YCC3060A units are rated at 80.0 AFUE with the following exceptions: 4YCC3018A1040 is rated at 79.8 AFUE 4YCC3024A1064 is rated at 79.0 AFUE 4YCC3030A1075 is rated at 79.5 AFUE 13 SINGLE PACKAGED GAS/ELECTRIC SYSTEMS PRODUCT DATA Typical Field Wiring UNIT CONTROL BOX GROUND WIRE 1 PH POWER 3 PH POWER UNIT NOTE 1 B COMMON G FAN (GR) Y COMPRESSOR W1 HEAT FIRST STAGE (WH) W2 HEAT SECOND STAGE (WH) R 24V B COMMON G FAN(GR) Y COMPRESSOR W1 HEAT FIRST STAGE (WH) W2 HEAT SECOND STAGE (WH) R 24V B G (GR) Y W1 (WH) W2 (WH) R C 757192i2 14 MODELS 4YCC3018 - 4YCC3060 Typical Field Wiring Models 4YCC3018060 - See Service Facts for detailed wiring diagrams of the individual models 15 SINGLE PACKAGED GAS/ELECTRIC SYSTEMS PRODUCT DATA Typical Field Wiring Models 4YCC3018060 - See Service Facts for detailed wiring diagrams of the individual models 16 Optional Equipment Baycurb050a Full Perimeter Roof Mounting Curb for 4YCC3018-036 46 3/8 17 7/8 MODELS 4YCC3018 - 4YCC3060 3 3 5/8 15 38 7/8 1 1/2 19 1/2 19 1/2 2 3/16 14 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 35 7/8 43 3/8 17 SINGLE PACKAGED GAS/ELECTRIC SYSTEMS PRODUCT DATA BAYCURB051A Full Perimeter Roof Mounting Curb for 4YCC3042-060 56 1/8 15 7/8 3 1 1/2 20 41 7/8 19 1/2 19 1/2 10 7/8 4 3/4 14 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 38 7/8 53 1/8 18 MODELS 4YCC3018 - 4YCC3060 BAYECON101,102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) HVAC Unit A Economizer rain hood Mist eliminator Relief damper Roofcurb Outside air dampers Return air dampers Required filter kit, order separately Return Duct ECONOMIZER BAYECON101A BAYECON102A UNIT APPLICATION MODELS 4TC*,WC*,YC*,DC* *018-036 4TC*,WC*,YC*, DC* *042-060 A 20.125" 24.375" BAYECON200,201A Horizontal Economizer and Rain Hood The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer Economizer A is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. B C D Duct E Gaskets (2) Rain Hood ECONOMIZER BAYECON200AA BAYECON201AA Mixed Air Sensor A B C D E F 22" 20" 16-7/8" 15-11/16 11-11/16 15 26" 22-21/32" 19" 17-11/16 14-11/16 21-3/8 19 SINGLE PACKAGED GAS/ELECTRIC SYSTEMS PRODUCT DATA BAYOSAH001,002A, 25% Outside Air Damper (Replaces Filter/Coil Access Panel) The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. A D C MANUAL FRESH AIR MODEL UNIT APPLICATION MODELS A B C D BAYOSAH001 4YC,WC3018-036 4TC*3018-036 4W/T/Y/DCY4024-036 4W/Y/DCZ6036 22 7/16" 20 11/16" 12 3/8" 9 3/16" BAYOSAH002 4YC,WC3042-060 4TC*3042-060 4W/T/Y/DCY4042-060 4W/Y/DCZ6048-060 25 3/16" 20 11/16" 12 3/8" 9 3/16" BAYDMPR101,102A, 25% Motorized Outside Air Damper (Mounts Over Horizontal Return AIr Opening) A FULLY OPEN 2/3 1/3 FULLY B CLOSED E BAYDMPR101A BAYDMPR102A UNIT APPLICATION MODELS 4YC,WC3018-036 4TC3018-036 4W/T/Y/DCY4024-036 4W/Y/DCZ6036 4YC,WC3042-060 4TC3042-060 4W/T/Y/DCY4042-060 4W/Y/DCZ6048-060 A B C D E 15 13/16" 11 13/16" 10 1/4" 11 1/2" 12 1/4" 18 3/16" 15 1/8" 10 1/4" 11 1/2" 12 1/4" 20 C B D BAYFLTR101, 201B, 1" - 2" Filter Rack (Mounts in Filter/Coil Section) MODELS 4YCC3018 - 4YCC3060 Filter BAYACCDOR1A & BAYACCDOR2A Hinged Filter Access Door Replaces Filter/Coil Access Panel The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 21 SINGLE PACKAGED GAS/ELECTRIC SYSTEMS PRODUCT DATA Dimensional Data and Weights NOTE: The view labeled "Bottom Side" represents the base as viewed looking up from underneath the unit. Figure 1. 4YCC3018 through 4YCC3036 (1 of 3) 22 Dimensional Data and Weights MODELS 4YCC3018 - 4YCC3060 Figure 2. 4YCC3018 through 4YCC3036 (2 of 3) 23 SINGLE PACKAGED GAS/ELECTRIC SYSTEMS PRODUCT DATA Dimensional Data and Weights Figure 3. 4YCC3018 through 4YCC3036 (3 of 3) 24 Dimensional Data and Weights MODELS 4YCC3018 - 4YCC3060 Figure 4. YCC3042 through YCC3060 (1 of 3) 25 SINGLE PACKAGED GAS/ELECTRIC SYSTEMS PRODUCT DATA Dimensional Data and Weights Figure 5. 4YCC3042 through 4YCC3060 (2 of 3) 26 Dimensional Data and Weights MODELS 4YCC3018 - 4YCC3060 Figure 6. 4YCC3042 through 4YCC3060 (3 of 3) 27 Mechanical Specifications General All units shall be factory assembled, piped, internally wired and fully charged with refrigerant. All units shall be designed to operate at outdoor ambient temperatures as high as 115°F Cooling capacities shall be rated in accordance with AHRI standards. The YC heating/cooling unit design is certified to ANSI 221.47/CSA 2.3, specifically for outdoor applications using natural gas or propane. All units shall be designed for outdoor rooftop or ground level installation. Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint. Shipped for horizontal application, convertible to downflow. Casings All panels shall be heavy gauge steel, gasketed and insulated. Foilfaced fiber insulation shall be in the heat exchanger section. Foil-faced insulation shall be in the evaporator section. Base pan shall be heavy gauge steel. WEATHERGUARDTM exterior corrosion resistant screws shall be used for added resistance to rust and corrosion. Controls Refrigeration cycle controls shall include condenser fan, evaporator fan and compressor contactors. Compressors shall be equipped with a combination internal winding thermostat/current overload. Internal high pressure relief shall also be provided. Refrigeration System Compressors -- The Climatuff® compressor features internal over temperature and pressure protector, total dipped hermetic motor. Other features include: centrifugal oil pump, and low vibration and noise. Evaporator Coil -- Internally enhanced 3/8inch OD seamless copper tubing mechanically bonded to aluminum fins, factory pressure and leak tested at 250 to 300 psig. All units have TXV to control refrigeration flow. Condenser Coil -- The Spine FinTMcondenser coil shall be continuously wrapped, corrosion resistant all aluminum with minimum brazed joints. This coil is 3/8 inch O.D. seamless aluminum tubing glued to a continuous aluminum fin. Coils are lab tested to withstand 2,000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Indoor Air Fan -- Direct-drive, forward-curved, centrifugal wheel in a Composite Vortica® Blower housing. Motor shall have thermal overload protection. Permanently lubricated motor bearings. Motor/blower assembly isolated from unit with rubber mounts. Condenser Fan -- Direct-drive, draw thru propeller type. Weather-proofed permanent split capacitor fan motor shall have built-in thermal overload and permanently lubricated motor bearings. Low Ambient -- Standard refrigerant system operation down to 55°F. Low ambient accessory required for operation to 0°F ambient condition. Heating System Gas-Fired Heating Section -- Models shall provide completely assembled, wired and piped gas fired heating systems within unit. Design certified by UL, specifically for outdoor application. Threaded gas connection on the unit. Electronic Ignition System -- Main burner is lit each time thermostat calls for heat. Flame sensor proves flame and keeps the main burners on. Should a loss of flame occur, the main valve closes and the spark recurs within 0.8 second. When thermostat is satisfied, main burner is extinguished. Forced Combustion Blower -- Insures flame stability under varying wind conditions. Gives higher combustion efficiency and location flexibility. Heat Exchanger -- stainless steel tubes. Free floating design. Burners -- stainless steel. Multi-port inshot. Downflow Accessories (U.S. Domestic Models) Roof Curb -- The roof curb shall be designed to mate with the unit and provide support and complete weather-tight installation when properly installed. Curb shall ship knocked down for field assembly, and include wood nailer strips. Economizer Modulating Economizer -- This accessory shall be field installed and be composed of the following items: 0-100% fresh air damper, damper drive motor fixed dry bulb enthalpy control, and low voltage polarized plug for electrical connections. Solid state enthalpy or differential enthalpy control is optional. Economizer operations shall be controlled by the preset position of the enthalpy control. A barometic relief damper shall be standard with the economizer and provide a pressure operated damper that shall be gravity closing and prohibit entrance of outside air on equipment "off" cycle. Manual Fresh Air Hood Manual outside air provides a fixed outside air quantity from 0 to 25 percent. Includes hood and birdscreen. Low Ambient Control Control allows cycling of compressor under low ambient cooling conditions. Required for cooling operation to 0°F. Propane Gas Conversion Kit -- For conversion from natural gas to LP gas. 6200 Troup Highway - Tyler, TX 75707 www.trane.com The Manufacturer has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice.Adobe PDF Library 9.9 Adobe InDesign CS5 (7.0.4)