Infinity Living 12K DIYCOOL R454B Std. Heat Mini-Split System

Indoor Unit Model#: EZ-12W-HP115B

Outdoor Unit Model#: EZ-12Z-HP115B

System Type: 12K (115V) DIYCOOL R454B Std. Heat Mini-Split System

Certifications: AHRI Certified, ETL Listed

Efficiency Ratings & Performance

Efficiency Ratings

Category Cooling Heating
SEER2 19.5 HSPF2-4: 9.3
EER2 9 COP: 3.25

Cooling Performance

Item Value
Rated Capacity 12000 Btu/hr
Min/Max Capacity 7400 ~ 12100 Btu/hr
Moisture Removal 1.33 L/h
Standard Operating Range -13 ~ 75 °F (-25 ~ 50 °C)
Conditions Indoor: 80°F DB/67°F WB, Outdoor: 95°F DB/75°F WB

Heating Performance

Item Value
Rated Capacity 12000 Btu/hr
1. @ 47°F Min/Max Capacity 4300 ~ 12700 Btu/hr
2. @ 17°F Rated Capacity 7400 Btu/hr
3. @ 5°F Rated: Capacity / COP 6700 / 2.20
3. @ 5°F Max: Capacity 6700 Btu/hr
Standard Operating Range -13 ~ 122 °F (-25 ~ 24 °C)
Conditions 1 Indoor: 70°F DB/60°F WB, Outdoor: 47°F DB/43°F WB
Conditions 2 Indoor: 70°F DB/60°F WB, Outdoor: 17°F DB/15°F WB
Conditions 3 Indoor: 70°F DB/60°F WB, Outdoor: 5°F DB/5°F WB

Unit Specifications

Indoor Unit Specifications

Specification Value
Air Flow (Turbo/H/M/L/Si) 353.2 / 294.3 / 235.4 / 176.6 / 129.5 CFM
Noise Level (Turbo/H/M/L/Si) 44.5 / 40.0 / 35.0 / 25.5 / 17.5 dBA
Dimension (W×D×H) 31.57 × 7.87 × 11.61 inch (802 × 200 × 295 mm)
Package (W×D×H) 35.43 × 15.75 × 13.39 inch (900 × 400 × 340 mm)
Net/Gross Weight 24.91 / 35.71 lbs (11.3 / 16.2 kg)

Outdoor Unit Specifications

Specification Value
Compressor Type ROTARY
Compressor Model KSK103D33UEZ3
Refrigerant R454B
Refrigerant Oil Charge 310 mL
Refrigerant Oil VG74
Outdoor Air Flow (Max) 1800 CFM
Outdoor Noise Level 54.0 dBA
Dimension (W×D×H) 28.35 × 10.63 × 19.49 inch (720 × 270 × 495 mm)
Package (W×D×H) 32.56 × 13.46 × 21.06 inch (827 × 342 × 535 mm)
Net/Gross Weight 54.89 / 67.24 lbs (24.9 / 30.5 kg)

Electrical Specifications

Item Value
Power Supply 115V, 60Hz, 1Ph
System MCA 19.5 A
Connection Wiring 14#x4
System MOCP 20 A
Compressor RLA 14.3 A
Outdoor Fan Motor RLA 0.5 A
Outdoor Fan Motor W 34 W
Indoor Fan Motor RLA 0.6 A
Indoor Fan Motor W 20 W
System Power Input @ Cooling 1333 W (630 ~ 1320 W)
System Power Input @ Heating 1082 W (235 ~ 1120 W)
Notes MCA: Min. circuit amps (A), MOCP: Max. over current protection (A), RLA: Rated load amps (A), W: Fan motor rated output (W)

Refrigerant Piping Specifications

Item Value
Throttle type (Indoor) N/A
Throttle type (Outdoor) Capillary
Liquid Size 6.35mm (1/4in)
Gas Size 9.52mm (3/8in)
Max. Piping Length 82 ft (25 m)
Max. Height Difference 49.20 ft (15 m)
Max. Pre-charged Length 24.6 ft (7.5 m)
Refrigerant Pre-charged Amount 21.52 oz (0.61 g)
Additional Charge of Refrigerant 0.16 oz/ft (15 g/m)
Connection Method Connector

Indoor Unit Dimensions & Installation

Indoor Unit Dimensions

Capacity Body Code W (inch/mm) D (mm/inch) H (mm/inch)
9K A 28-3/4in/729mm 7-7/8in/200mm 11-1/2in/292mm
12K B 31-5/8in/802mm 7-7/8in/200mm 11-5/8in/295mm
18K C 38-1/4in/971mm 9in/228mm 12-5/8in/321mm
24K D 42-5/8in/1082mm 9-1/4in/234mm 13-1/4in/337mm

Indoor Unit Installation Instructions

The indoor unit is shown with labels for Width (W), Depth (D), and Height (H). A mounting plate with holes for wall installation is depicted.

Piping Exit Options: The unit allows for piping to exit from the left-hand side, right-hand side, left rear, or right rear. The choice depends on the wall hole position relative to the mounting plate.

Wall Hole Size Note: If the gas side connective pipe is 5/8 inch (16mm) or larger, the wall hole should be 3-1/2 inches (90mm).

Specific indoor unit dimensions shown: Width x Height: 31.7in (806mm) x 11.65in (296mm).

Outdoor Unit Dimensions & Installation

Outdoor Unit Dimensions

The outdoor unit is depicted with key dimensions labeled: W2 (28-5/8in/727), W (28-3/8in/720), W1 (31-1/8in/790), D (10-5/8in/270), H (19-1/2in/495). Detail A shows connection points A1 (1/2in) and A2 (1-7/8in).

Outdoor Unit Installation Instructions

The outdoor unit is illustrated on base supports, with clearance requirements indicated:

  • 20in (500mm) or more when front and sides of the unit are clear.
  • 4in (100mm) or more on the sides.
  • 14in (350mm) or more on the rear.
  • 20in (500mm) or more when any 2 sides (left, right, and rear) of the unit are clear.

A checkmark symbol indicates that the unit meets all specified installation clearance requirements.

Features

  • Indoor unit TU1 copper coil
  • Humidity control
  • 1~100% fan speed setting
  • WiFi capability: through WiFi dongle or wired controller with built-in WiFi
  • OTA (by using WiFi dongle)
  • Multiple control options available:
    • Two way communication wired controller: 120N(X6)
    • Two way communication wired controller with built-in WiFi: 120N(X6W)
    • Infrared wired controller: 120L
    • Wireless remote controller
    • Third-Party 24V Thermostat*
  • *24V interface is required.

PDF preview unavailable. Download the PDF instead.

Infinity-DIYC-STDSZ-Sub-12W-HP115B-12Z-HP115B-072325 Acrobat Distiller 25.0 (Windows)

Related Documents

Preview Infinity Living EZ-12WPL-HP115B Mini-Split System Submittal Data Sheet
Submittal data sheet for the Infinity Living EZ-12WPL-HP115B / EZ-12ZPL-HP115B 12K BTU single-zone mini-split air conditioning system, detailing cooling and heating performance, efficiency ratings, specifications, and installation clearances.
Preview Infinity Living 18K DIYCOOL Mini-Split System: Submittal Data Sheet & Specifications
Detailed submittal data sheet for the Infinity Living 18K DIYCOOL R454B Platinum/Ext. Heat Single-Zone Mini-Split System (EZ-18W-MB indoor, EZ-18ZPL-HP230B outdoor), including efficiency ratings, performance data, electrical specifications, and dimensions.
Preview Infinity Living EZ-24W-HP230B / EZ-24Z-HP230B 24K DIYCOOL Mini-Split System Submittal Data Sheet
Submittal data sheet for the Infinity Living 24K DIYCOOL R454B Std. Heat Mini-Split System, detailing indoor and outdoor unit specifications, cooling and heating performance, electrical data, and refrigerant piping information.
Preview Infinity Living Platinum Single-Zone & Multi-Zone Air Handlers Service Manual
Comprehensive service manual for Infinity Living Platinum Single-Zone and Multi-Zone Air Handlers with DIYCOOL Technology. Covers model numbers EZ-09W-MB, EZ-12W-MB, EZ-12WPL-HP115B, EZ-18W-MB, EZ-24W-MB, EZ-36W-MB, EZ-12ZPL-HP115B, EZ-18ZPL-HP230B, EZ-24ZPL-HP230B, and EZ-36ZPL-HP230B. Includes safety precautions, specifications, product features, maintenance, and troubleshooting guidance.
Preview Infinity Living Remote Controller User Manual for Air Handlers
Comprehensive user manual for Infinity Living single-zone and multi-zone air handlers, detailing remote controller functions, specifications, and operation for models like EZ-09W-HP115B, EZ-12W-HP115B, RG10R(M2S)/BGEFU1, and others. Includes quick start guide, button descriptions, screen indicators, basic and advanced functions, timer settings, and FCC compliance information.
Preview Infinity Living EZ-18W-HP230B/EZ-18Z-HP230B Mini-Split System Submittal Data
Submittal data sheet for the Infinity Living 18K DIYCOOL R454B Standard Heat Mini-Split System (EZ-18W-HP230B/EZ-18Z-HP230B), detailing cooling/heating performance, efficiency ratings, electrical specifications, and installation guidance.
Preview Infinity Living EZ-48-HPB/EZ-48-AHB 48K DIYCOOL R454B Heat Pump Submittal Data Sheet
Technical specifications, performance data, and dimensions for the Infinity Living 48K DIYCOOL R454B Ducted Air Handler and Extended Heat Pump Condenser (Models EZ-48-HPB/EZ-48-AHB).
Preview Infinity Living EZ-CONNECT Single-Zone System Installation and Owner's Manual
This manual provides comprehensive installation and owner's instructions for the Infinity Living EZ-CONNECT Single-Zone System with DIYCOOL Technology. It covers safety precautions, unit specifications, operation, maintenance, troubleshooting, and installation procedures for both indoor and outdoor units.