Submittal Data Sheet
Indoor Unit Model#: EZ-18W-MB
Outdoor Unit Model#: EZ-18ZPL-HP230B
18K DIYCOOL R454B Platinum/Ext. Heat Single-Zone Mini-Split System
Location: [Not Specified]
Engineer: [Not Specified]
Submitted to: [Not Specified]
Submitted by: [Not Specified]
Reference: [Not Specified]
Approval: [Not Specified]
Date: [Not Specified]
Construction: [Not Specified]
Unit #: [Not Specified]
Drawing #: [Not Specified]
Efficiency Ratings
Rating | Cooling | Heating |
---|---|---|
SEER2 | 22.5 | HSPF2-4: 11.5 |
EER2 | 13.7 | COP: 4.02 |
Cooling Performance
Parameter | Value |
---|---|
Rated Capacity (Btu/hr) | 18000 |
Min/Max Capacity (Btu/hr) | 7700 ~ 20600 |
Moisture Removal (L/h) | 1.49 |
Standard Operating Range (°F/°C) | -13 ~ 75 (-25 ~ 50) |
Conditions | 1. @ 47°F Rated Capacity: Indoor: 80°F DB/67°F WB, Outdoor: 95°F DB/75°F WB |
Heating Performance
Parameter | Value |
---|---|
Rated Capacity (Btu/hr) | 18000 |
Min/Max Capacity (Btu/hr) | 8100 ~ 22600 |
@ 17°F Rated Capacity (Btu/hr) | 13400 |
@ 5°F Rated Capacity / COP | 12800 / 2.44 |
@ 5°F Max Capacity (Btu/hr) | 12800 |
Standard Operating Range (°F/°C) | -13 ~ 122 (-25 ~ 24) |
Conditions | 1. @ 47°F: Indoor: 70°F DB/60°F WB, Outdoor: 47°F DB/43°F WB 2. @ 17°F: Indoor: 70°F DB/60°F WB, Outdoor: 17°F DB/15°F WB 3. @ 5°F: Indoor: 70°F DB/60°F WB, Outdoor: 5°F DB/5°F WB |
Indoor Unit Specifications
Parameter | Value |
---|---|
Indoor Air Flow (Turbo/H/M/L/Si) (CFM) | 671.0 / 470.9 / 382.6 / 323.7 / NA |
Indoor Noise Level (Turbo/H/M/L/Si) (dBA) | 54.5 / 44.5 / 40.5 / 30.5 / 19.0 |
Dimension (W×D×H) (inch) | 42.52 x 8.90 x 13.19 |
Dimension (W×D×H) (mm) | 1080 x 226 x 335 |
Package (W×D×H) (inch) | 46.73 x 17.68 x 14.26 |
Package (W×D×H) (mm) | 1187 x 449 x 363 |
Net/Gross Weight (lbs) | 35.49 / 49.60 |
Net/Gross Weight (kg) | 16.1 / 22.5 |
Outdoor Unit Specifications
Parameter | Value |
---|---|
Compressor Type | ROTARY |
Compressor Model | KSN140D58UFZ |
Refrigerant | R454B |
Refrigerant Oil Charge (mL) | 440 |
Refrigerant Oil | VG74 |
Outdoor Air Flow (Max) (CFM) | 3000 |
Outdoor Noise Level (dBA) | 58.5 |
Dimension (W×D×H) (inch) | 35.04 x 13.46 x 26.50 |
Dimension (W×D×H) (mm) | 890 x 342 x 673 |
Package (W×D×H) (inch) | 40.55 x 18.11 x 29.53 |
Package (W×D×H) (mm) | 1030 x 460 x 750 |
Net/Gross Weight (lbs) | 93.48 / 114.20 |
Net/Gross Weight (kg) | 42.4 / 51.8 |
Electrical Specifications
Parameter | Value |
---|---|
Power Supply | 208/230V, 60Hz, 1Ph |
System MCA | 18 |
Connection Wiring | 14#x4 |
System MOCP | 20 |
Compressor RLA | 10.0 |
Outdoor Fan Motor RLA | 0.9 |
Outdoor Fan Motor W | 80 |
Indoor Fan Motor RLA | 0.6 |
Indoor Fan Motor W | 58 |
System Power Input @ Cooling (W) | 1300 (550 ~ 1690) |
System Power Input @ Heating (W) | 1280 (405 ~ 1670) |
MCA: Min. circuit amps (A) | [See System MCA] |
MOCP: Max. over current protection (A) | [See System MOCP] |
RLA: Rated load amps (A) | [See Compressor RLA, Fan Motor RLA] |
W: Fan motor rated output (W) | [See Fan Motor W] |
Refrigerant Piping Specifications
Parameter | Value |
---|---|
Throttle type (Indoor) | N/A |
Throttle type (Outdoor) | EXV+Throttle valve |
Liquid Size | 6.35mm (1/4in) |
Gas Size | 12.7mm (1/2in) |
Max. Piping Length (ft/m) | 98.40 (30) |
Max. Height Difference (ft/m) | 65.60 (20) |
Max. Pre-charged Length (ft/m) | 24.6 (7.5) |
Refrigerant Pre-charged Amount (oz/g) | 44.80 (1.27) |
Additional Charge of Refrigerant ((oz/ft)/(g/m)) | 0.16 (15) |
Connection Method | Connector |
Indoor Unit Dimensions and Installation
The indoor unit dimensions are provided in diagrams showing the width (W), depth (D), and height (H) of the unit. A table details these dimensions in both inches and millimeters for various capacities. Installation instructions include a note advising to choose the side from which the piping will exit the unit, based on the wall hole position relative to the mounting plate, offering four options for piping exit direction. Another note specifies that if the gas side connective pipe is 16mm (5/8 inch) or more, the wall hole should be 90mm (3-1/2 inch).
Indoor Unit Dimensions Table
Capacity | Body-Code | W (inch/mm) | D (inch/mm) | H (inch/mm) |
---|---|---|---|---|
12K (115V) | B | 31-1/2in / 802mm | 7-1/2in / 89mm | 11-3/4in / 297mm |
18K | E | 42-1/2in / 1080mm | 8-7/8in / 226mm | 13-1/4in / 335mm |
24K | E | 42-1/2in / 1080mm | 8-7/8in / 226mm | 13-1/4in / 335mm |
36K | F | 49-1/2in / 1259mm | 11-1/8in / 282mm | 14-1/4in / 362mm |
Outdoor Unit Dimensions and Installation
Diagrams illustrate the outdoor unit's dimensions, including width (W, W1, W2, W3), depth (D, D1, D2, D3), and height (H, H1, H2), along with connection points labeled A, A1, A2, B1, B2. Installation instructions specify required clearances around the unit:
- 20 inches (500mm) or more clearance when the front and sides of the unit are clear.
- 4 inches (100mm) or more clearance on the rear.
- 14 inches (350mm) or more clearance on the sides.
Features
- Indoor unit TU1 copper coil
- Humidity control
- 1~100% fan speed setting
- WiFi capability: through WiFi dongle or wired controller with built-in WiFi
- OTA (Over-The-Air updates) using WiFi dongle
- Multiple control options available:
- Two-way communication wired controller: 120N(X6)
- Two-way communication wired controller with built-in WiFi: 120N(X6W)
- Infrared wired controller: 120L
- Wireless remote controller
- Third-Party 24V Thermostat*
*24V interface is required.
Related Documents
![]() |
Infinity Living Platinum Single-Zone & Multi-Zone Air Handlers Service Manual Comprehensive service manual for Infinity Living Platinum Single-Zone and Multi-Zone Air Handlers with DIYCOOL Technology. Covers model numbers EZ-09W-MB, EZ-12W-MB, EZ-12WPL-HP115B, EZ-18W-MB, EZ-24W-MB, EZ-36W-MB, EZ-12ZPL-HP115B, EZ-18ZPL-HP230B, EZ-24ZPL-HP230B, and EZ-36ZPL-HP230B. Includes safety precautions, specifications, product features, maintenance, and troubleshooting guidance. |
![]() |
Infinity Living EZ-18W-HP230B/EZ-18Z-HP230B Mini-Split System Submittal Data Submittal data sheet for the Infinity Living 18K DIYCOOL R454B Standard Heat Mini-Split System (EZ-18W-HP230B/EZ-18Z-HP230B), detailing cooling/heating performance, efficiency ratings, electrical specifications, and installation guidance. |
![]() |
Infinity Living EZ-24W-HP230B / EZ-24Z-HP230B 24K DIYCOOL Mini-Split System Submittal Data Sheet Submittal data sheet for the Infinity Living 24K DIYCOOL R454B Std. Heat Mini-Split System, detailing indoor and outdoor unit specifications, cooling and heating performance, electrical data, and refrigerant piping information. |
![]() |
Infinity Living 12K DIYCOOL R454B Std. Heat Mini-Split System Submittal Data Sheet Technical specifications and performance data for the Infinity Living 12K (115V) DIYCOOL R454B Std. Heat Mini-Split System, including indoor and outdoor unit details, efficiency ratings, and installation clearances. |
![]() |
Infinity Living EZ-48-HPB/EZ-48-AHB 48K DIYCOOL R454B Heat Pump Submittal Data Sheet Technical specifications, performance data, and dimensions for the Infinity Living 48K DIYCOOL R454B Ducted Air Handler and Extended Heat Pump Condenser (Models EZ-48-HPB/EZ-48-AHB). |
![]() |
Infinity Living Multi-Zone Air Handler Installation & Owner's Manual Comprehensive installation and owner's manual for Infinity Living Multi-Zone Air Handler systems (models EZ-09W-MB to EZ-36W-MB), covering setup, operation, safety, and maintenance. |
![]() |
Infinity Living Remote Controller User Manual for Air Handlers Comprehensive user manual for Infinity Living single-zone and multi-zone air handlers, detailing remote controller functions, specifications, and operation for models like EZ-09W-HP115B, EZ-12W-HP115B, RG10R(M2S)/BGEFU1, and others. Includes quick start guide, button descriptions, screen indicators, basic and advanced functions, timer settings, and FCC compliance information. |
![]() |
Infinity Living EZ-18W-MB DIYCOOL Air Handler Submittal Data Sheet Technical specifications and features for the Infinity Living EZ-18W-MB DIYCOOL 18K Wall Mounted Air Handler, including dimensions, electrical, and refrigerant piping details. |