1. Identify System Wires

Compressor Motor Wiring:

The compressor motor has three wires typically labeled 'C' (Common), 'S' (Start), and 'R' (Run).

Electrical Connections:

The system is powered by Line Voltage (L1/Hot and L2/Neutral) through a Thermostat-Controlled On/Off Switch.

Components:

You can install EasyStart into any system when you identify the compressor "C", "S", and "R" wires in your system's electric box.

2. EasyStart Wiring

Wiring Diagram with EasyStart Installed:

The below electrical criteria are true for installation into any system. Continue to the next section for a typical installation.

3. Typical Installation

Disconnect power from your A/C unit using the A/C breaker.

Locate the three compressor motor wires (C, S, and R) coming from the compressor and follow them into the electric box. Use the wiring diagram for your unit to help.

EasyStart Orange

Follow the "S" wire to where it lands in the electric box. Connect EasyStart orange alongside it. This is typically a terminal group of a silver run capacitor, labelled "H" or "Herm".

Disconnect Any Other Start-Assist Devices

Inspect where the "S" wire landed for any other connected wires and follow them. If they go to a start capacitor, start relay, or PTCR then remove this wire at both ends.

EasyStart Black

Follow the compressor "C" wire to where it lands or passes though the electric box. Cut the "C" wire at a convenient location and strip both ends about 3/8" (10mm). Twist the strands of each wire end to itself. Combine these two stripped ends and EasyStart black using the provided three-way lever connector. Lift the empty terminal levers, slide each wire in fully, and close them.

Compressor "R" Wire

Follow the "R" wire to where it lands in the electric box. Pull the wire from its terminal and cut off the connector.

NOTE: It is easy to mistake other wires for the compressor "R" wire. Take extra precaution when identifying this wire.

EasyStart Brown

Connect the EasyStart brown wire to the Compressor "R" wire you just cut. Strip the wire and twist its strands together. Open the empty lever, slide in the stripped wire fully, and close the lever.

Strip Length Indication: 1/2" or 3/8" (13mm or 11mm)

EasyStart White

Connect the EasyStart white wire to the terminal that you removed compressor "R" from.

Install Complete - EasyStart Learning Starts

Restore power to the A/C and let the A/C cycle naturally on mains power. EasyStart will learn the characteristics of your compressor on the first few cycles. Please allow at least 5 cycles to complete before operating on a limited power source.

4. Further Resources

Our EasyStart Knowledge Bank has further resources to learn more about EasyStart. Below are some highlights:

If you have questions or issues after reading our resources then please submit your information on our Contact Us page. Detail the questions or issue you have, what resources you have used, and steps you have tried. Include pictures that further describe what you need help with.

https://www.micro-air.com/contact_microair.htm

Version 1.0

Micro-Air LLC ©2025 www.micro-air.com

Models: EasyStart Breeze AC Soft Starter For RV and Marine Air Conditioners, Breeze AC Soft Starter For RV and Marine Air Conditioners, AC Soft Starter For RV and Marine Air Conditioners, Starter For RV and Marine Air Conditioners, RV and Marine Air Conditioners, Marine Air Conditioners

File Info : application/pdf, 6 Pages, 1.19MB

PDF preview unavailable. Download the PDF instead.

EasyStart-Breeze-quick-install

References

cairo 1.17.7 (https://cairographics.org) Inkscape 1.3 (https://inkscape.org)

Related Documents

Preview EasyStart Home AC Wiring Installation Guide
Comprehensive installation guide for Micro-Air EasyStart ASY-364 and ASY-368, detailing safety precautions, component identification, step-by-step wiring instructions, and specific procedures for different system configurations.
Preview EasyStart Troubleshooting: System Not Cooling Guide
A comprehensive troubleshooting guide for Micro-Air EasyStart systems when the air conditioning is not cooling. Includes initial steps, LED diagnostics, voltage checks, and further resources.
Preview Micro-Air EasyStart Home AC Wiring Installation Guide
Comprehensive guide for installing the Micro-Air EasyStart system in various home air conditioning units. Covers safety precautions, system identification, component identification, wiring instructions for different system types (including Comfort Alert and Emerson Comfort Control), and troubleshooting.
Preview EasyStart Universal Installation Kit - KIT-364-368-RT2 - Micro-Air
Micro-Air's EasyStart Universal Installation Kit (KIT-364-368-RT2) provides essential components for installing EasyStart soft starters in RV, Marine, and Residential applications. View the complete list of included parts.
Preview Easy Start 364 & 368 Soft Starter Installation Manual
Comprehensive installation manual for Micro Air's Easy Start soft starters, models 364 (3 ton) and 368 (6 ton). Includes detailed wiring instructions, troubleshooting tips, and jumper usage guide.
Preview EasyTouch RV 356 Quick Start Guide - Micro-Air
Quick start guide for the Micro-Air EasyTouch RV 356 thermostat, providing essential setup, installation, and basic operation instructions for RV heating and cooling systems.
Preview EasyTouch RV Thermostat: Installation, Quick Start Guide, and Operation Manual
Comprehensive guide for the Micro-Air EasyTouch RV Thermostat, covering installation, setup, operation, smart device connectivity, and troubleshooting for RV climate control.
Preview EasyTouch RV Operations Manual: Your Guide to RV Thermostat Control
Comprehensive operations manual for EasyTouch RV thermostats, covering setup, features, scheduling, troubleshooting, and wireless connectivity. Learn to optimize your RV's climate control with detailed instructions and tips.