Product Notice
Only a technician authorized by ENERMAX is allowed to perform maintenance service. Warranty is subject to void under unauthorized attempts to open the power case or modification of any kinds, even attempted only, of the power supply or its components.
ENERMAX is not responsible for damages caused by the following situations:
- Opening of the PSU case and/or modification of any component or cable without ENERMAX written authorization.
- Ignoring connector's wrong insertion prevention design by attaching a connector to a device in wrong orientation.
- Connecting too many devices to one cable unit by using additional adaptors (Y cables).
- The serial number label or warranty seal is defaced, modified, or removed.
- Damage caused by natural phenomena or uncontrollable forces, such as lightning, flooding, fire, earthquake, etc.
⚠️ Main plug is used as the disconnect device; the disconnect device shall remain ready for operating.
⚠️ Apparatus shall be connected to a MAINS socket outlet with a protective earthing connection.
This ENERMAX Technology Corporation product is warranted to be free from defects in material and workmanship for a period of five (5) years from the date of purchase. The warranty length may be different in diverse regions based on local policy.
ENERMAX Technology Corporation agrees to repair or replace the product, at its own option and at no charge, if, during the warranty period, it is returned to the nearest ENERMAX Technology Corporation subsidiary/agent with all shipping charges prepaid and bearing a return merchandise authorization (RMA) number, and if inspection reveals that the product is defective. Charges for removing or installing the product are excluded under the terms of this warranty agreement. This warranty shall not apply to any product which has been subject to connection to a faulty power source, alteration, negligence, or accident, or to any product which has been installed other than in accordance with these instructions. In no event shall ENERMAX Technology Corporation, or its subsidiaries, or agents be liable for damages for a breach of warranty in an amount exceeding the purchase price of this product!
For support, please visit our website:
- Global: Website: www.enermax.com/en, E-mail: enermax@enermax.com.tw
- Taoyuan: Website: www.enermax.com, E-mail: support-tw@enermax.com.tw
- Germany: Website: www.enermax.de, E-mail: support@enermax.de
- Korea: Website: enermaxkorea.com, E-mail: enermax@cynex.co.kr, TEL: (02)719-2580, 080-719-2581, FAX: (02) 6713-2654
For questions or problems, contact our support team at www.enermax.com/support.
Component List
Important! Before starting installation, check that all parts in the box contents are complete. If any part is missing or damaged, contact your place of purchase.
- A PSU x 1
- B Motherboard 24 pin x 1 (60cm cable)
- C CPU 4+4 pin x 1 (750/850W) / x 2 (1000W) (65cm cable)
- D CPU 4+4 pin (2 connectors) x 1 (650/750/850W) (60cm + 15cm cable)
- E 12V-2x6 12+4 pin x 1 (60cm cable)
- F 12V-2x6 to PCIe 6+2 pin (2 connectors) x 1 (1000W) (60cm cable)
- G PCIe 6+2 pin x 1 (750/850/1000W) (60cm cable)
- H PCIe 6+2 pin (2 connectors) x 1 (650/750/850W) (55cm + 15cm cable)
- I SATA (3 connectors) + 4P Molex (1 connector) x 2 (650W) / x 3 (750/850/1000W) (45cm + 15cm + 15cm + 15cm cable)
- J Mounting Screws x 4
- K AC Cord x 1 (Actual AC cord depends on different area.)
Product Introduction
*The actual product depends on different regions or countries.
Diagram showing the layout of the ENERMAX REVOLUTION III PSU connectors, including labels for CPU/PCIe, 12V-2x6, and Motherboard ports. Arrows indicate connection types (C or D or G or H for CPU/PCIe, I for SATA/Molex, E or F for 12V-2x6). Diagram showing the rear panel of the PSU, highlighting the I/O Switch (Individual PSU ON/OFF switch: I=ON, O=OFF) and the AC power input socket (K).I/O Switch: Individual PSU ON/OFF switch (I=ON, O=OFF).
The I/O switch function is available in multiple languages, including German, French, Italian, Spanish, Japanese, Chinese, Russian, Polish, Korean, Thai, Persian, and Turkish.
Installation - Cables
Motherboard 24 pin
Connect the 24-pin motherboard power.
Instructions are provided in multiple languages (German, French, Italian, Spanish, Japanese, Chinese, Russian, Polish, Korean, Thai, Farsi, Turkish).
Diagram illustrating the connection of the 24-pin motherboard power cable (B) to the motherboard.CPU 4+4 pin
Connect the 4+4 pin CPU power.
Instructions are provided in multiple languages (German, French, Italian, Spanish, Japanese, Chinese, Russian, Polish, Korean, Thai, Farsi, Turkish).
Diagram illustrating the connection of the CPU 4+4 pin power cable (C or D) to the CPU power connector on the motherboard.12V-2x6 12+4 pin
Connect the 12+4 pin connector to your GPU as required.
Instructions are provided in multiple languages (German, French, Italian, Spanish, Japanese, Chinese, Russian, Polish, Korean, Thai, Farsi, Turkish).
Diagram illustrating the connection of the 12V-2x6 12+4 pin cable (E) to a GPU.PCIe 6+2 pin
Connect the PCIe connectors to your GPU as required.
Instructions are provided in multiple languages (German, French, Italian, Spanish, Japanese, Chinese, Russian, Polish, Korean, Thai, Farsi, Turkish).
Diagram illustrating the connection of PCIe 6+2 pin cables (F, G, or H) to a GPU.SATA
Connect the SATA as needed.
Instructions are provided in multiple languages (German, French, Italian, Spanish, Japanese, Chinese, Russian, Polish, Korean, Thai, Farsi, Turkish).
Diagram illustrating the connection of SATA power cables.4P Molex
Connect the 4P molex to your fans as required.
Instructions are provided in multiple languages (German, French, Italian, Spanish, Japanese, Chinese, Russian, Polish, Korean, Thai, Farsi, Turkish).
Diagram illustrating the connection of 4P Molex cables to case fans.Cable Usage Warning
⚠️ Please only use the modular cables provided in your ENERMAX power supply package. Do NOT use other cables to prevent pin configuration damage to your system and your power supply.
This warning is reiterated in multiple languages.
How to Install 12V-2x6 Properly?
Diagram showing correct (fully inserted) vs. incorrect (not fully inserted) connection of the 12V-2x6 connector. Diagrams illustrating correct cable bending with a minimum distance of 35mm from the connectors, versus incorrect bending too close to the connectors.Please avoid vertically or horizontally cable bending too close to the connectors. We suggest a minimum distance of 35mm from the connectors before bending.
Installation - PSU
Step 1: Diagram showing the PSU (A) being mounted into the computer case and secured with mounting screws (J). Step 2: Diagram showing the AC power cord (K) being connected to the PSU.Specification
Model | 650W | 750W | 850W | 1000W | ||||
---|---|---|---|---|---|---|---|---|
AC Input Voltage | 100-240VAC, 50-60Hz | |||||||
AC Input Current | 10-6A | 10-6A | 15-8A | 8A(for China only) | ||||
DC Output | ||||||||
Rated | Combined | Rated | Combined | Rated | Combined | Rated | Combined | |
+3.3V | 20A | 100W | 20A | 100W | 20A | 100W | 20A | 100W |
+5V | 20A | 20A | 20A | 20A | ||||
+12V | 54.1A | 649.2W | 62.4A | 748.8W | 70.8A | 849.6W | 83.3A | 999.6W |
-12V | 0.4A | 4.8W | 0.4A | 4.8W | 0.4A | 4.8W | 0.4A | 4.8W |
+5Vsb | 2.5A | 12.5W | 2.5A | 12.5W | 2.5A | 12.5W | 3.0A | 15W |
Total Power | 650W | 750W | 850W | 1000W | ||||
Environment | ||||||||
Temp. | Operating: 0°C to +40°C Non-operating: -40°C to +70°C |
|||||||
Humidity | Operating: 20% to 85% relative humidity (non-condensing). Non-operating: 5% to 95% relative humidity (non-condensing). |
|||||||
Others | ||||||||
Power Factor | PF > 0.95 at full load | |||||||
Cooling | One 12cm FDB Fan | |||||||
MTBF | 100K hours minimum | |||||||
Dimension | 150(W)*86(H)*140(D) mm |
Protection
- OCP (Over Current Protection): OCP makes sure that the output of the DC voltage rails remains within safe operating limits.
- OVP (Over Voltage Protection): OVP shuts down the PSU when the DC outputs exceed a certain level, which is determined by the PSU manufacturer.
- UVP (Under Voltage Protection): UVP shuts off the PSU when the voltage is under the certain standard.
- OPP (Over Power Protection): OPP shuts off the PSU when the power drawn is between 130% ~ 170% of the rated power.
- OTP (Over Temperature Protection): OTP makes sure that the PSU will shut down when the internal temperature reaches a set point.
- SCP (Short Circuit Protection): SCP makes sure that the PSU shuts down when the 3.3V, 5V, and 12V rails short to any other rail, or to ground. It also ensures that no damage should occur to the unit, or your PC's components in the event of a short.
FAQ
- Can't find out the 4 pin CPU cable. We provide 4+4 pin CPU cables, it can be used in split mode.
- How to connect 8 pin PCIe with 6+2 pin PCIe cable? Combine the 6 pin and 2 pin before connecting it to the GPU.
- How to connect the motherboard cable? Plug in the 18 pin and 10 pin connectors to the PSU, and insert the 24 pin connector to the motherboard.
- Can't power up the PSU successfully. Check if the motherboard and CPU cables are connected to the motherboard exactly, or the PSU will not work.
- After installing a new GPU, the PC system crashes frequently. It means the PSU is inadequate for your GPU. Before purchasing the PSU, please refer to our PSU calculator tool on the ENERMAX website.
Safety Precautions
Please follow the instructions in the product safety and operation manual. Pay attention to all warning messages on the product and in the operation manual.
This product is for limited use. To avoid personal injury, electric shock, fire, or damage to your device, please observe the following precautions:
General Precautions:
- Maintenance: Only authorized technicians should perform maintenance. Unauthorized attempts to open or modify the PSU can lead to electric shock and void the warranty.
- Damaged Components: If power cords, plugs, or the unit itself are damaged, or if liquid or foreign objects enter the unit, unplug it and contact authorized service.
- High Temperatures: Keep the product away from heat sources.
- Humidity: Do not use the product in humid environments.
- Foreign Objects: Do not insert objects into ventilation slots.
- Installation Platform: Ensure the PSU is installed on a stable platform using manufacturer-recommended accessories.
- Children: Avoid use in areas accessible to children.
Power Cord and Accessory Safety:
- Correct Power Source: Use only the specified power type and voltage.
- Voltage Selection: Ensure any voltage selection switch is set correctly.
- Approved Power Cords: Use only locally approved power cords meeting the product's specifications (min 0.75 mm² wire gauge, 1.2-2m length).
- Cable Routing: Route cords safely to prevent damage or tripping hazards.
- Overload: Do not overload circuits or extension cords; stay within 80% of rated capacity.
Correct Use of Power Cords and Connectors:
- Plug into a grounded, accessible outlet.
- Do not disable the ground pin.
- Unplug by grasping the plug, not the cord.
Enclosure Requirements for PSU Installation:
For safety, the PSU must be installed in an enclosure meeting these criteria:
- Metal or aluminum enclosure material.
- Circular openings: max 5mm diameter.
- Slotted openings: max 5mm diagonal (or unrestricted length if width < 1mm).
- No openings on the bottom.
Declaration of the Presence Condition of the Restricted Substances Marking
This section details the presence of restricted substances in various components according to standards.
Table listing components (case, wire, circuit board, resistor, etc.) and the presence of restricted substances like Lead (Pb), Mercury (Hg), Cadmium (Cd), Hexavalent Chromium (Cr+6), Polybrominated biphenyls (PBB), and Polybrominated diphenyl ethers (PBDE). Symbols indicate whether the substance exceeds, does not exceed, or is exempt from the reference percentage value.Note 1: "Exceeding 0.1 wt %" and "exceeding 0.01 wt %" indicate that the percentage content of the restricted substance exceeds the reference percentage value.
Note 2: "o" indicates that the percentage content of the restricted substance does not exceed the reference percentage value.
Note 3: "-" indicates that the restricted substance corresponds to the exemption.
Social Media & Contact
Follow ENERMAX on social media for the latest information and share your build with the hashtag #ENERMAX.
- Facebook: https://www.facebook.com/OfficialENERMAX
- Instagram: https://www.instagram.com/OfficialENERMAX
- Twitter: https://twitter.com/OfficialENERMAX
- YouTube: https://www.youtube.com/@OfficialENERMAX
© 2024, ENERMAX Technology Corporation.
2F-1, No. 888, Jing-Guo Road, Taoyuan City (330)
Tel. +886-3-316-1675, Fax. +886-3-346-6640
All rights reserved. Actual product and accessories may differ from illustrations. Information in this manual is subject to change without prior notice. Printing errors and omissions excepted. All trademarks, registered trademarks and/or product names mentioned are the property of their respective owners.