Lutron LED+ Dimmer Quick Install Guide
Model: RCL-153PNL
Specifications: 120 V~ 60 Hz
Load Ratings: 150 W LED / CFL, 600 W Incandescent / Halogen
Install with Confidence
Use included diagrams or visit our website for step-by-step instructions.
For video instructions, visit: lutron.com/CLwiring
To find the right LED, visit: lutron.com/LEDfinder
Important Notes:
- Use only with permanently installed fixtures with dimmable screw-in compact fluorescent, dimmable screw-in LED, halogen, or incandescent lamps.
- Do not use to control receptacles, motor-driven appliances, or transformer-supplied appliances to avoid overheating and damage to other equipment.
- Install in accordance with all national and local electrical codes.
- If no grounding means exists in the wallbox, a control can be installed as a replacement when a plastic faceplate with plastic fasteners is used, or the circuit is protected by a ground fault circuit interrupter (GFCI). Lutron wallplates meet this requirement. Cap or remove the green wire before screwing the control into the wallbox.
- Protect the dimmer from dust and dirt when painting or spackling the wall.
- It is normal for the dimmer to feel warm to the touch during operation.
- Clean the dimmer with a soft damp cloth only. Do not use chemical cleaners.
- For indoor use only.
Installation Instructions
Before installing: Remove the rotary knob and the light ring.
WARNING: ELECTRIC SHOCK HAZARD. May result in serious injury or death. Turn off power at circuit breaker or fuse before installing.
Step 1: Pull knob
[Pull hard]
Step 2: Remove ring
[Pinch sides and pull]
Wiring Diagrams
Single Pole (Lights switched from one location):
Wiring:
- Connect the dimmer's black and red wires (interchangeable) to the load and line wires.
- Connect the ground wire (bare or green) to the dimmer's green wire.
- Use the blue connector for wire connections.
Note: Black and solid red wire on the dimmer are interchangeable.
3-Way (Lights switched from two locations):
IMPORTANT: Mark or tag the common wire (connected to the different colored screw) before removing the old switch.
Wiring:
- Connect the dimmer's wires according to the diagram, ensuring the common wire is correctly identified.
- Connect the ground wire (bare or green) to the dimmer's green wire.
Note: Only one dimmer can be used in a 3-way circuit.
Ganging and Derating: Derating is necessary if mounting two or more devices side by side. Refer to the chart for new wattage ratings. Derating is not necessary for LED/CFL loads.
Maximum Allowable Inc. / Hal. Wattage:
Configuration | Max Wattage |
---|---|
Single Gang (No side devices) | 600 W |
One side device removed | 450 W |
Two side devices removed | 300 W |
After Installation: Adjust Low-End Dimming Range for LEDs and CFLs
- Push the shaft to turn lights ON and rotate counter-clockwise to adjust the low-end.
- Move the adjustment lever up or down to adjust the low-end dimming range.
- Push the shaft to turn lights OFF and ON to verify proper operation.
Note: It may be helpful to attach the knob for this step.
Mount Dimmer and Restore Power
1. Attach faceplate
[Attach faceplate]
2. Note the UP arrow
[Note UP arrow]
3. Push light ring on
[Push light ring]
4. Push knob on firmly
[Push knob firmly]
Troubleshooting and Support
For troubleshooting, please visit: www.lutron.com/support
For limited warranty information, visit: www.lutron.com/warranty or call 1.844.LUTRON1.
To receive an extended warranty, visit: www.lutron.com/CLregistration
Support: 1.844.LUTRON1 (USA / Canada) | +1.888.235.2910 (Mexico)
Lutron and LED+ are trademarks or registered trademarks of Lutron Electronics Co., Inc. The YouTube icon is a trademark of Google LLC.