Intended Use

The ZEISS DTC 4 | 50 is intended for mounting in front of an optical device for displaying heat signatures. It is suitable for nature observation, remote hunting observations, and civil use. This device is not a toy for children. Use the device only as described in the user manual. The manufacturer and dealer accept no liability for damages arising from non-intended or incorrect use.

Safety Instructions

Handling when used with a riflescope on a firearm

  • Check the legal and regional regulations in your country before using the ZEISS DTC 4 with a riflescope.
  • If the ZEISS DTC 4 is connected to an optical device used on a firearm, always ensure that the firearm is unloaded when mounting the ZEISS DTC 4.
  • Before using, ensure that your riflescope and the ZEISS DTC 4 are in proper working condition.
  • Test the correct setting of the point of impact using controlled shots.
  • Improper or inaccurate mounting of the ZEISS DTC 4 on the riflescope may result in a shift in the point of impact, which may affect accuracy.
  • An incorrectly adjusted ZEISS DTC 4 may result in a considerable deviation of the point of impact.

General Handling

  • Look through your riflescope to test if the optics provide a clear, undisturbed image.
  • If handled roughly, a maladjustment cannot be ruled out.
  • Never point the lens of the device directly at intense heat sources such as the sun or laser equipment. The objective lens and eyepiece can function as a burning glass and damage interior components.
  • Protection class IP65 / IP67 is only achieved when all rubber covers are firmly closed.

Danger of Swallowing

  • Do not place this device in the hands of small children. Incorrect handling can cause small parts to come loose which may be swallowed.

Battery Safety

  • Handle the device with care: rough handling can damage the internal battery.
  • Do not expose the device to fire or high temperatures above 60°C.
  • Do not disassemble the device to access the battery. The battery is not meant to be replaced by the end user.
  • Only charge the device at temperatures ranging between 10°C and 40°C.
  • Battery capacity decreases when operated in cold ambient temperatures; this is technical and not a defect.
  • Do not store the device for long periods at temperatures below 0°C or above 35°C, as this permanently reduces battery capacity.

Power Supply Unit Safety

  • Check your power supply unit (not included) and cable for visible damage before use.
  • Do not use defective parts and observe the safety instructions for your power supply unit.
  • The power supply must meet the requirements for limited power sources according to IEC 62368-1 (Annex Q) or IEC 60950-1 (LPS, Chapter 2.5).

Legal and Regulatory Information

Radio Module Information

  • Frequency range WLAN: 2.400-2.474.5 MHz, Max power: 20 mW
  • Frequency range Bluetooth: 2.402-2.480 MHz, Max power: 5 mW

Carl Zeiss AG hereby declares that the radio equipment type ZEISS DTC 4/50 complies with Directive 2014/53/EU and Directive 2011/65/EU. The full text of the EU declaration of conformity is available at: www.zeiss.com/cop/conformity

Some certification marks supported by the ZEISS DTC 4 can be displayed on the device screen. Navigate to System > Regulatory Infos.

USA Regulatory Information

FCC ID: 2AMSP-DTC450

Product Model Number (PMN): DTC 4/50

1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation.

2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user's authority to operate the equipment.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

To comply with RF exposure requirements, a minimum separation distance of 0.00 cm must be maintained between the user's body and the handset, including the antenna. This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment.

Name of Responsible Party: Carl Zeiss SBE, LLC / Consumer Products, ZEISS Group, One North Broadway, Suite 1501, White Plains, NY, 10601, USA. Phone: +1 800 858 6745

Carl Zeiss Inc. declares that this product was tested conforming to applicable FCC rules and measures.

Canada Regulatory Information

IC: 22938-DTC450

Product Model Number (PMN): DTC 4/50

Manufacturer's self-declaration of compliance with ISED's ICES standards: CAN ICES-3 (B)/NMB-3(B)

This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

To comply with RF expose requirements, a minimum separation distance of 0.00 cm must be maintained between the user's body and the handset, including the antenna. This device complies with ISED RF radiation exposure limits set forth for an uncontrolled environment.

Disposal Information

Disposal of Batteries (European Union)

? This symbol indicates that the battery used in this product may not be disposed of in domestic waste and must be collected for disposal separately. When returning used batteries, please use a collection system that may exist in your country and refer to qualified personnel to have the battery removed from the device. Instructions for removing the battery are available at www.zeiss.com/cop/recycling.

The materials and substances in the battery may have a detrimental impact on health and the environment. By depositing empty batteries at a recycling facility, you contribute to the protection and conservation of our environment. Please only return discharged batteries. The battery used does not contain mercury, cadmium or lead in quantities exceeding the limits defined in Directive 2006/66/EC.

Disposal of Electrical and Electronic Devices (Private Households - European Union)

♻️ The WEEE symbol on products and/or accompanying documents indicates that used electrical and electronic products must not be mixed with ordinary household waste. For proper treatment, recovery, and recycling, take these products to the appropriate collection points where they will be accepted without charge. In some countries, it may also be possible to return these products to your local retailer when you purchase a corresponding new product.

The proper disposal of this product serves to protect the environment and prevents possible harmful effects on human beings and their surroundings, which may arise as a result of incorrect handling of waste. More detailed information on your nearest collection point is available from your local authority. In accordance with state legislation, penalties may be imposed for the improper disposal of this type of waste. Please note that it is your responsibility to delete personal data before disposing of the device.

Disposal for Business Customers

  • Germany: ZEISS offers business users the option to return used ZEISS equipment free of charge, unless otherwise agreed. Contact your sales organization before returning equipment.
  • European Union: Please contact your dealer or supplier for disposal of electrical and electronic devices.
  • Outside the European Union: Please contact your local authority or dealer for disposal options.
Models: DTC 450 Thermal Imaging Accessories, DTC 450, Thermal Imaging Accessories, Imaging Accessories, Accessories

File Info : application/pdf, 6 Pages, 81.95KB

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=6972143

References

Adobe InDesign 18.1 (Windows) Adobe PDF Library 17.0

Related Documents

Preview ZEISS DTC 3/25, 3/35, 4/50 Accumulator Removal and Recycling Guide
Provides essential safety instructions and step-by-step guidance for the proper removal and recycling of the accumulator from ZEISS DTC 3/25, 3/35, and 4/50 thermal imaging devices. Follow these procedures for safe handling and disposal.
Preview ZEISS DTC 4/50 Firmware Update: Maximized Accuracy
Detailed release notes and installation guide for the ZEISS DTC 4/50 thermal clip-on device firmware update. Learn about new features, bug fixes, and how to update your device via the ZEISS Hunting App.
Preview ZEISS DTC 4/50 Gebrauchsanleitung
Bedienungsanleitung für das ZEISS DTC 4/50 Wärmebildvorsatzgerät. Enthält Informationen zu Installation, Bedienung, technischen Daten und Fehlerbehebung.
Preview ZEISS DTC 3/38 | 3/25 Gebrauchsanleitung
Anleitung zur Verwendung des ZEISS DTC 3/38 und 3/25 Wärmebildvorsatzgeräts. Enthält Informationen zu Installation, Bedienung, technischen Daten, Fehlerbehebung und Wartung.
Preview ZEISS DTI 6/20 & 6/40 Safety and Regulatory Information
Comprehensive safety, handling, battery, power supply, intended use, and regulatory information for the ZEISS DTI 6/20 and DTI 6/40 thermal imaging devices. Includes disposal guidelines and FCC/IC compliance.
Preview VISCOJECT-BIO 2.2 Injector Set Handling Instructions for 4-Point Haptic IOLs | ZEISS
Detailed handling instructions for the ZEISS VISCOJECT-BIO 2.2 Injector Set, designed for 4-point haptic IOLs. Learn step-by-step usage for ophthalmic procedures.
Preview ZEISS Quality Assurance Solutions for eMobility: Enhancing Safety and Performance
Discover ZEISS's comprehensive quality assurance solutions for the eMobility sector, covering batteries, electric motors, fuel cells, automotive electronics, and transmissions. Enhance safety, performance, and reliability with advanced metrology and inspection technologies from ZEISS.
Preview ZEISS Pickup Order Form
Official pickup order form for ZEISS logistics services, detailing shipment information, recipient and billing addresses, and preferred shipping options.