Notifier RLD Remote Display
The RLD is a distance annunciator designed for Notifier INSPIRE™ series fire alarm control panels (FACPs) or network control displays (NCDs). It provides a remote display connected via a serial interface, featuring a five-inch touchscreen for system status, point information, and event counters. The RLD can display up to two events simultaneously and allows system control via six programmable soft-touch buttons, plus dedicated Receive Acknowledge, Silence, Reset, and Exercise buttons.
Generalities
The RLD serves as a remote annunciator for FACPs or NCDs, offering a serial connection. Its five-inch touchscreen displays system status, point information, and event counters, capable of showing two events at once and scrolling through up to 50 prioritized system events. The RLD also facilitates system control through six programmable soft-touch buttons and dedicated Receive Acknowledge, Silence, Reset, and Exercise buttons.
The N16 FACP supports a maximum of 10 RLDs configured as routers, each occupying one of the 10 available router addresses. Routers can be a mix of ACM-30 and RLD units. The RLD does not support peripheral annunciators.
Features
- Five-inch high-definition touchscreen.
- Key switch for user authentication, enabling commands for Receive Acknowledge, Silence, Reset, and Exercise.
- Configurable control buttons that function only when the key switch is unlocked.
- Receive Acknowledge, Silence, Reset, Exercise options.
- Six programmable buttons, each with a description/label, status indicator, and configurable action (off/on, disable/enable).
- Remote power supply supervision.
- Field programmable using VeriFire® tools and touchscreen interactive commands.
- USB C connection.
- Ability to filter displayed events on the RLD by zone.
- Option to associate the RLD with a dedicated trigger zone, displaying the zone label, status, and a countdown timer if applicable.
- The RLD mounts in a standard 3-gang electrical box.
- Seismic certified for seismic applications when used with the appropriate seismic mounting kit.
- Positive Alarm Sequence (PAS) participation. Network or local PAS participation as programmed in the panel or NCD.
- Pre-signal participation.
- Signal disable and automatic signal disable options.
- Compliant with Canadian ULC display requirements.
- Programmable exercise participation (fire drill for ULC) and support for active alarm signal (ULC specific).
- Zone event display option with event count per zone (ULC specific).
- Support for Display and Control Center (DCC) functionality (ULC specific).
- Language selection on the panel: English, Canadian French, Spanish, and Portuguese.
Panel Compatibility
- N16 Series
- NCD
Network Options
Two-wire serial communication with limited power AIO to signaling line circuits for N16 or NCD panels.
Installation
The RLD is mounted in a standard 3-gang electrical box. External connections include the 2-wire serial AIO communication, 24 VDC power input, and ground.
Communication between the RLD and control panels is via a 2-wire, limited-power serial AIO interface, supervised by the fire alarm control panel. Each RLD requires a 24 VDC limited-power supply. Loss of RLD power is registered as a communication failure at the control panel. The RLD can also be powered from a listed, limited-power, regulated remote supply for fire protective signaling use.
Box
- ABB-2: Display box for RLD mounting (requires DP-ADP). UL/ULC listed.
- ABB-2D(C): Surface mount display box. Requires DP-ADP for RLD mounting.
Specifications
Electrical Specifications
- Primary Power Input: 24 VDC, 200 mA
Shipping Weight
- 0.91 kg
Dimensions
- 17.8 cm
- 5.75 in. (14.6 cm) H
- 1 in. (2.54 cm) D
Temperature and Humidity Ranges
This system complies with NFPA requirements for operation between 0 and 49 °C (32 and 120°F) and at 93% ± 2% RH (non-condensing) at 32 °C ± 2 °C (90 °F ± 3 °F). However, the service life of system backup batteries and electronic components may be compromised by extreme temperatures and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal ambient temperature of 15 - 27 °C / 60 - 80 °F.
Agency Listings and Approvals
File numbers mentioned below relate to specific listings for modules discussed in this document. In some cases, certain modules or applications may not yet be listed by listing organizations or may be pending approval. Please consult NOTIFIER for the status of the latest approval. For current product approval status, please contact the factory.
- UL/ULC Listed: S635
- FM Approved: FM23FPUS0095
- CSFM: 7165-0028:0516
- FDNY: COA#001761
- Seismic Certified for seismic applications per IBC 2024: VMA-45894-01C
- OSHPD Approved: OSP-0072
Standards
The following listings and approvals apply to the RLD. In some cases, certain modules or applications may not yet be listed by listing organizations or may be pending approval. For current product approval status, please contact the factory.
- UL 864, 10th Edition (Control Units and Accessories for Fire Alarm Systems).
- UL2017 (General-Purpose Signaling Devices and Systems).
- UL 2610 (Commercial Security Alarm Units and Systems).
- ULC-S527-19 (Control Units and Accessories for Fire Alarm Systems).
- Must be installed in accordance with NFPA 72 of the National Fire Protection Association.
Typical Configuration
A diagram shows a typical configuration where a fire alarm control panel communicates with a signaling line circuit (AIO) to up to ten RLD annunciators. The RLDs are powered by a 18-30VDC supply and connect via a two-wire AIO circuit.
Contact Information
NOTIFIER 12, Clintonville Street Northford, CT 06472 203.484.7161 www.notifier.com