Avigilon 4-Door Smart Hub Quick Start Guide
Model: SYS-4ENT-DVE1
This guide provides instructions for the installation and setup of the Avigilon 4-Door Smart Hub.
What's Included
- 4-Door Smart Hub enclosure
- 4-Door Control Core
- 4-Door Sensing
- Mounting template
- Bracket and push-in fasteners
- 4-Port Expansion Board (multiple included)
Overview
The Avigilon 4-Door Smart Hub is a central component for managing access control for up to four doors. It integrates with the Avigilon Alta Control Center for system management.
1 - Mounting
- Use the provided paper template to mark and pre-drill holes for the enclosure. Install two fasteners (not included), leaving their heads extended from the wall to act as anchors.
- Hang the enclosure onto the two fasteners. Tighten the fasteners securely to the wall. Use two additional fasteners (not included) to secure the bottom of the enclosure to the wall.
2 - Installing Components
- Open the enclosure.
- Install the expansion board into the enclosure using the included standoffs (quantity 4).
- Install the Access Control Core below the expansion board using the included bracket. Secure the top of the enclosure using the included fasteners (not included).
3 - Wiring
Warning: Do not apply power during wiring. Ensure the Smart Hub is unplugged until all wiring is complete.
- Connect the Access Control Core to the Expansion Board using the included USB cable (see diagram 1).
- Connect the Access Control Core to an Ethernet cable with Internet access (see diagram 2).
- Connect the Access Control Core and the Expansion Board to the power supply using the included power cables (see diagram 3).
4 - Connecting Avigilon Readers or Wiegand Readers
Connect Avigilon readers or Wiegand readers to the designated ports on the Access Control Core. Note: LCD and BZR connections are not supported.
5 - Connecting Locks or Strikes
Wire fail-safe or fail-secure locks or strikes to the appropriate terminals. A fail-safe lock unlocks when power is lost, while a fail-secure lock remains locked.
6 - Powering the Device
Warning: Do not attempt to wire connections within the Smart Hub while power is enabled.
- For installations in Europe or requiring a 220VAC power source, cut the jumper on the power supply module.
- Plug the power cord into a 110VAC or 220VAC power source. An example of a North American power cord and outlet is shown.
7 - Provisioning
To begin provisioning, you will need an Avigilon Alta Control Center user account. Create and register for an account by visiting: https://control.openpath.com/login or https://control.eu.openpath.com/login.
8 - Connecting Devices
Follow the steps within the Avigilon Alta Control Center to connect devices to your organization. In the app, tap 'Devices' at the bottom.