Avigilon OP-CR-SDC Single Door Controller Quick Start Guide
What's Included
- Single Door Controller
- Cover
- Mounting backplate
- Drywall anchors
- Electrical box screws
- Set screw for securing SDC to backplate
- Self-tapping screws
- Hex key for set screw
Overview
The Single Door Controller features the following:
- 1: Admin button and Status LED indicator ?
- 2: Ethernet port ?
- 3: USB ports ?
- 4: Port LED indicators
Status LED Indicator
Status LED | Description |
---|---|
Solid white | Normal operation |
Solid cyan | Booting |
Solid yellow | Restoring software |
Blinking yellow | Updating software |
Solid blue | Unprovisioned state |
Solid purple | Connected to Avigilon Alta Access app |
Blinking purple | Ready to connect to Avigilon Alta Access app |
Blinking red | No internet |
Solid red | Error, see Avigilon Alta Control Center |
Port LED Indicators
Port LED | Avigilon readers or Wiegand Readers | Sensors, including REX and Contact Sensors | Lock hardware including relays |
---|---|---|---|
Solid | Normal operation | Active | Relay is energized |
Blinking | Error state | EOL shorted or cut | Fault detection |
1 - Mounting
- Attach the backplate to a single or double gang electrical box using the included electrical box screws (two or four screws, respectively). For added stability on drywall, use the included drywall anchors and self-tapping screws.
- Snap the Single Door Controller onto the backplate. Ensure the side clips on the backplate (a) fit into their notches on the back of the controller (b).
- Use the included hex key to tighten the pre-installed set screw on the Single Door Controller to secure it to the backplate.
- Wire the Single Door Controller (refer to section 2 - Wiring). Use the cable slot to hold cables while wiring.
2 - Wiring
Warning: Do not apply power during wiring. Ensure the power supply is unplugged until all wiring is complete.
- Snap on the cover. Note: Removal of the front cover will trigger tamper detection during normal operation.
- Apply power using either DC or PoE.
Power Supply Options:
- Example: North American power cord and outlet.
- SD card must not be removed unless instructed by Avigilon Alta Support.
- 24V locking hardware requires PoE or a 24V power supply.
- For backup or if PoE is not available: Use a 12V @ 2.2A (min) or 24V @ 1.1A (min) power supply. 24V is required if locking hardware requires 24V.
Caution: Certified external power source (complies with LPS) must be used.
To power relays without an external supply, select 12V or 24V, and connect locking hardware to NO/NC and GND. To use external power, select DRY and use NO/NC and C, and wire to the external supply.
Warning: Power off the Single Door Controller before changing the voltage of the relays.
3 - Provisioning
- Before you start, you will need an Avigilon Alta Control Center user account. To create and register for an account, visit: control.openpath.com/login or control.eu.openpath.com/login.
- Follow the steps in Alta Control Center to create an organization and add devices.
- To connect devices to an organization, use the Avigilon Alta Access app.
- In the app, tap 'Devices' at the bottom.
- Tap 'Scan for Devices' or the add button [plus-symbol], and follow the instructions.
App Store® and the Apple logo® are trademarks of Apple Inc. Google Play and the Google Play logo are trademarks of Google LLC.
Compliance Information
FCC Compliance
Any changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.
Industry Canada Notice and Marking
This device complies with the ISED radiation exposure limit set forth for an uncontrolled environment. This device should be installed and operated with a minimum distance of 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Cet équipement est conforme avec l'exposition aux radiations ISED définies pour un environnement non contrôlé. Cete équipement doit être installé et utilisé à une distance minimum de 20 cm entre le radiateur et votre corps. Cet émetteur ne doit pas être co-localisées ou opérant en conjonction avec une autre antenne ou transmetteur.
This device contains licence-exempt transmitter(s) that comply with Innovation, Science and Economic Development Canada's license-exempt RSS(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
L'émetteur exempt de license contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement Économique Canada applicables aux appareils radio exempts de license. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
The frequency and the maximum transmitted power in EU is listed below. Bluetooth LE (2402-2480MHz): 2 dBm
Caution: Use only the Power Sourcing Equipment certified by UL 62368-1 (compliant with LPS) for the Single Door Controller (Power Limited/Class2).
Certifications
The Single Door Controller is certified with:
- CE
- IC
- FCC
- UKCA
- RCM
- NOM
- ANATEL
- UL294
Countries: BE, BG, CZ, DK, DE, EE, IE, EL, ES, FR, HR, IT, CY, LV, LT, LU, HU, MT, NL, AT, PL, PT, RO, SI, SK, FI, SE
For More Information
Visit the Avigilon Video Library for additional resources.
© 2024, Avigilon Corporation. All rights reserved. AVIGILON and the AVIGILON logos are trademarks or registered trademarks of Avigilon Corporation. All other trademarks are the property of their respective owners. Unless stated explicitly and in writing, no license is granted with respect to any copyright, industrial design, trademark, patent or other intellectual property rights of Avigilon Corporation or its licensors.