Lindab OLR Mounting Guidance

Lindab | For a better climate

Mounting guidance, Montageanleitung, Guide de montage, Montageanvisning, Installationsvejledning

UK - Mounting Guidance

The outer ducts (4) are to be mounted in the wall and secured with four screws (3). On those ducts the front-plate brackets are fastened (2) in each side and are also mounted with a screw (3). The inner ducts (5) are mounted in the same way as the outer ducts (4) in the wall from the back. At last the frontplate is placed on the frontplate brackets (2) on both the front and the back of the wall. At first the frontplate is mounted on the lower part of the bracket (see fig. 1), after that the plate has to be pressed into position (see fig. 2) whereafter the frontplate has to be pulled down into position (see fig. 3).

Figure 1 shows the frontplate mounted on the lower part of the bracket.

Figure 2 shows the plate being pressed into position.

Figure 3 shows the frontplate pulled down into position.

SE - Montageanvisning

Ytterrör (4) monteras i vägg och fastskruvas med fyra skruvar (3). Därefter sätts frontplattehållarna (2) på var sida och monteras med en skruv (3).

Innerröret (5) monteras på samma sätt som ytterröret (4) i vägg från baksidan. Slutligen sätts frontplattan (1) på frontplattehållarna (2) på fram och baksidan av väggen. Frontplattan monteras först på de nedre beslagen (se fig. 1), Därefter pressas plåten in (se fig. 2), varefter frontplåten dras ned på plats (se fig. 3).

DK - Installationsvejledning

Yderrør (4) monteres og fastgøres med fire skruer (3). Herpå monteres frontpladeholderne (2) på hver side og monteres med en skrue (3).

Inderrør (5) monteres på samme måde som yderrør (4) i væg fra bagsiden. Forpladen monteres først på nederste del af beslag (se fig. 1), derefter presses pladen ind (se fig. 2), hvorefter forpladen trækkes (se fig. 3).

DE - Montageanleitung

Der Außenstutzen (4) wird in die Wand montiert und mit vier Schrauben (3) befestigt. An diesen Stutzen werden die Frontplattenhalterungen (2) auf jeder Seite befestigt und mit einer Schraube (3) montiert. Der Innenstutzen (5) wird auf die gleiche Weise wie der Außenstutzen (4) von der Rückseite der Wand montiert. Zum Schluss wird die Frontplatte (1) auf die Frontplattenhalterungen (2) an der Vorder- und Rückseite der Wand montiert. Die Frontplatte wird zuerst von unten auf die Halterung montiert (siehe Abb. 1), danach wird die Platte in Richtung Wand über die Halterungen gedrückt (siehe Abb. 2). Zum Schluss wird sie nach unten gedrückt und ausgerichtet.

FR - Guide de montage

La manchette femelle (4) doit être montée sur le mur et fixée avec 4 vis (3). Sur cette manchette, les étriers (2) doivent être montés à chaque extrémité et fixés avec des vis (3). La manchette mâle (5) doit être montée de la même manière que la manchette femelle (4) depuis l'autre coté du mur. Enfin, les façades sont fixées sur les supports (2) de chaque coté du mur. Dans un premier temps, monter la façade sur le bas de l'étrier (voir fig.1), puis positionner la façade sur le haut (voir fig.2). Verrouiller ensuite l'ensemble en poussant la façade vers le bas (voir fig.4).

Parts list/Stückliste/Nomenclature/Stycklista/Stykliste:

Pos Pcs. Description/Anleitung/Description/Beskrivning/Beskrivelse
1 2 Frontplate/Frontplatte/Facade/Frontplattor/Frontplade
2 4 Frontplate bracket/Frontplattenhalterung/Etrier/Hållare till front plattor/Frontplade holder
4 4 Outer duct/Außenstutzen / Manchette femelle / Ytterrör / Yderrør
5 1 Inner duct/Innenstutzen/Innerör/Inderrør/Manchette mâle.

Most of us spend the majority of our time indoors. Indoor climate is crucial to how we feel, how productive we are and if we stay healthy.

We at Lindab have therefore made it our most important objective to contribute to an indoor climate that improves people's lives. We do this by developing energy-efficient ventilation solutions and durable building products. We also aim to contribute to a better climate for our planet by working in a way that is sustainable for both people and the environment.

Lindab | For a better climate

www.lindab.com

Models: OLR Four Sided Crosstalk Silencer, OLR, Four Sided Crosstalk Silencer, Sided Crosstalk Silencer, Crosstalk Silencer, Silencer

PDF preview unavailable. Download the PDF instead.

OLR-A installation GLOBAL

Related Documents

Preview Lindab Atrium Loggia / -H / -C Heating and Cooling Panels | Installation & Overview
Comprehensive guide to Lindab Atrium Loggia / -H / -C heating and cooling panels, covering delivery control, mounting options, water connections, and false ceiling integration. Learn about Lindab's energy-efficient HVAC solutions for improved indoor climate.
Preview Lindab OLC Overflow Unit - Installation Guide
Comprehensive installation instructions for the Lindab OLC overflow unit, including dimensions, accessories, and step-by-step mounting guidance for OLC and OLCZ models.
Preview Lindab Solus Ventilation Baffle Installation and Mounting Guide
Comprehensive installation instructions and mounting details for the Lindab Solus ventilation baffle, covering air and water connections, ceiling system compatibility, and accessories. Available in multiple languages.
Preview Lindab Access Door EPFH Mounting Instructions
Comprehensive mounting instructions for the Lindab Access Door EPFH, detailing installation steps, parts, and product features for optimal climate control solutions.
Preview Lindab TRC200 Mounting Instruction Guide
Official mounting instructions for the Lindab TRC200 shears, detailing how to attach it to an SR cutter bench. Learn about Lindab's commitment to indoor climate and sustainability.
Preview The Indoor Climate Briefing: Importance of Healthy Indoor Air and Sustainable Buildings
This briefing explores the critical importance of indoor air quality (IAQ) for health, productivity, and building longevity. It details the five key factors of healthy indoor air – carbon dioxide, relative humidity, temperature, particulate matter, and volatile organic compounds – and examines regional differences in Europe. The document also highlights the role of sustainable buildings and energy efficiency in creating better indoor environments, concluding with a call to action for improved air quality in all spaces.
Preview The Indoor Climate Briefing: Understanding Healthy Indoor Air and Sustainable Buildings
An in-depth look at indoor air quality, its critical impact on health, productivity, and building longevity. This briefing explores key factors such as CO2, humidity, temperature, particulate matter, and VOCs, examining regional differences in Europe and the role of sustainable building practices.
Preview Lindab Ventilation Grill F50/51: Environmental Product Declaration
Environmental Product Declaration (EPD) for Lindab's F50/51 ventilation grill, detailing its life cycle assessment, environmental impact data, and sustainability aspects according to EN 15804+A2 and ISO 14025.