CADAC Universal Regulator 8510 User Instructions

CADAC Universal Regulator

Product Code: 8510

User Instructions

Languages: English, Dutch

Important Information

CAUTION: Ensure adequate ventilation. Use this device only outdoors.

IMPORTANT: Read these instructions carefully to become familiar with the device before connecting it to the gas cylinder. Keep these instructions for future reference.

NOTE! PRODUCT MAY VARY FROM ILLUSTRATIONS

1. Safety and Operating Conditions

  • The A310i / A300i pressure regulators are engineered to supply gas to an appliance at the specified pressure and capacity as indicated on the nameplate.
  • The A310i / A300i regulators are compatible with any gas cylinder equipped with a suitable valve for this hand-tightened connection. The gas cylinder must always be operated in an upright position.
  • When utilizing the A310i / A300i outdoors, ensure the unit is sufficiently protected from rain.
  • Perform a leak test each time you connect your regulator to an appliance or cylinder. Conduct leak inspections using soapy water; never use an open flame.
  • Do not use an appliance that leaks, is damaged, or is not functioning correctly.
  • In the event of a malfunction, immediately close the valve and contact the supplier.
  • If a leak ignites before the valve (2) can be closed, use a wet cloth to safely close the valve and protect yourself.
  • Under standard operating conditions, to maintain proper system functionality, it is recommended to replace the regulator within 5 years from the date of manufacture.
  • Do not move the cylinder while it is in use.
Gas typeButaneLPGPropane
Inlet pressure (bar)0.3-7.50.3-161-16
Nominal outlet pressure (mbar)28-3028-303037
ΔP2 (mbar)2222
Operating temperature0°C-50 °C-20°C-50°C-20°C-50°C
Capacity1.5kg/hr0.8kg/hr1.5kg/hr

2. Connecting the gas hose to the regulator outlet nozzle

  • Attach a rubber hose (3) to the hose nozzle (6) (apply water to the hose to facilitate easier insertion).
  • To ensure a secure connection, use the provided clamps (4) to firmly secure the hose (3).

Diagram Description: The diagram shows the gas regulator with numbered parts. Key components include the valve outlet (1), hex nut (9) for connecting to the cylinder, a gasket (5) on the valve outlet, and a hose nozzle (6) with clamps (4) for attaching the gas hose (3). An arrow (10) indicates the direction for tightening the hex nut.

3. Mounting on the Gas Cylinder

  • Ensure that:
    • All valves of the gas appliance are closed.
    • The gas hose to the gas appliance is correctly mounted.
  • Ensure no open flames are nearby. Remove the protective cap from the valve. Verify that the gasket (5) is present on the valve outlet (1) of the gas cylinder, then fully tighten the hex nut (9) with a wrench. Note the turning direction indicated by the arrow (10). The hex nut should be moderately tightened to ensure a leak-free connection.
  • Tighten the hex nut while holding the regulator steady, using a wrench. The regulator itself should never be rotated.

Leak Test

  • Do not use an appliance that leaks, is damaged, or is not functioning correctly.
  • Close all valves on the appliance and open the cylinder valve. Inspect all connection areas using a suitable foaming solution, never a flame.
  • If you suspect a gas leak, apply soapy water to the connection points (do not fully submerge the regulator in soapy water as this may lead to unsafe operation). If there is a leak, bubbles will form at the leak point.

Operation

  • The pressure regulator is ready for operation immediately after installation and leak check have been performed.
  • If the A310i / A300i is properly connected to the gas cylinder, the gas supply can be opened by turning the handwheel in the indicated direction. Turn the handwheel in the opposite direction to stop the gas supply.
  • Do not move the gas cylinder during operation.
  • The valve and regulator must be adequately protected from exposure to weather at all times.
  • Always be sure to close the cylinder valve when the cylinder is not in use.

4. Gas Cylinder Exchange

  • Ensure that:
    • All valves on the gas appliance are closed.
    • The cylinder valve of the gas cylinder is closed.
  • If all valves are closed, you can remove the A310i / A300i pressure regulator by loosening the connection from the gas cylinder.
  • Attach the regulator to a full cylinder by following the procedure as explained in section 3.
  • When the regulator is installed downstream of another regulator, ensure the supply pressure matches the regulated pressure of the upstream regulator, accounting for any pressure losses in the connecting pipework.
  • The downstream pressure loss in the installation must not exceed the ΔP-value marked on the device.
  • For regulators that can be connected directly to tank or cylinder pressure but not directly to the tank or cylinder outlet, the following statement applies: "This regulating device must not be placed lower than the tank outlet valve or cylinder outlet valve to prevent re-liquefied gas vapor from being drained into the regulator. Pipes and hoses used to connect to the inlet of this regulating device must continuously run back to the tank or cylinder."

5. Warranty

  • The statutory warranty period applies. If the product is defective, please contact your retailer or the manufacturer's branch in your country (see www.cadacinternational.com/support).
  • For repair and warranty processing, please include the following documents when you send in the product:
    • A copy of the receipt with purchasing date,
    • A reason for the claim or description of the fault.
  • Note that self-repair or non-professional repair can have safety consequences and might void the warranty.

Explanation of Symbols

  • [recycling symbol] Recycling packaging material. Place the packaging material in the appropriate recycling waste bins wherever possible.

Contact Information

  • DOMETIC MOBILE COOKING NETHERLANDS B.V.
    • Ratio 26, 6921 RW Duiven, The Netherlands
    • Tel: +31 26 319 7740
    • Email: info@cadaceurope.com
  • DOMETIC MOBILE COOKING UK LTD.
    • 114 Deanfield Court, Link59 Business Park, Clitheroe, Lancashire, BB7 1QS, United Kingdom
    • Tel: +44 (0) 333 2000363
    • Email: info@cadacuk.com

YOUR LOCAL DEALER: www.cadacinternational.com/support

Models: 8510, 503-0083_LEV3, 8510 Universal Regulator, 8510, Universal Regulator, Regulator

PDF preview unavailable. Download the PDF instead.

503-0083 LEV3 8510 UniversalRegulator UserManual EN-NL WEB Adobe PDF Library 17.0 Adobe InDesign 19.4 (Windows)

Related Documents

Preview Cadac LP CG Screw-On Regulator with Quick Release Connection User Manual
Operating instructions for the Cadac LP CG Screw-On Regulator with Quick Release Connection, Model No: 8515-FL-QR. Includes safety information, installation guide, gas level indicator, leak test procedure, and technical data.
Preview CADAC Safari Chef 30 LP Portable Gas Barbecue - Operating Manual
Comprehensive operating manual for the CADAC Safari Chef 30 LP portable gas barbecue, covering safety instructions, assembly, usage, maintenance, and technical specifications.
Preview CADAC Carri Chef 50 User Instructions
Comprehensive user instructions for the CADAC Carri Chef 50 gas barbecue, model number 8910. This guide covers assembly, safe operation, maintenance, troubleshooting, and warranty information.
Preview CADAC 2 Cook Pro Portable Gas Stove User Manual
Detailed user instructions and manual for the CADAC 2 Cook Pro portable gas stove. Covers assembly, operation, safety guidelines, maintenance, and troubleshooting for models 202PI and 202P0.
Preview Cadac Potjiekos Cooker Model No. 153 User Instructions
User instructions for the Cadac Potjiekos Cooker Model No. 153, including safety information, operating instructions, maintenance, troubleshooting, and spare parts.
Preview CADAC Safari Chef 30 HP User Instructions
Comprehensive user instructions for the CADAC Safari Chef 30 High Pressure portable gas grill, covering safety, assembly, operation, cleaning, maintenance, and troubleshooting.
Preview CADAC Citi Chef 50 User Instructions and Safety Guide
Detailed user manual for the CADAC Citi Chef 50 BBQ, covering setup, operation, safety precautions, maintenance, cleaning, and troubleshooting. Includes information on various cooking surfaces and international contact details.
Preview CADAC Gasversorgung Quad Power Pak for Camping and Grilling
Discover the CADAC Gasversorgung Quad Power Pak, a lightweight and portable gas solution for camping and outdoor activities. This system replaces traditional gas bottles and offers up to 8 hours of operation with four 227g gas cartridges. It features easy handling with a bayonet closure and quick-release connection, ensuring reliable performance even in cold temperatures. The universal 1/4" BSP left-hand thread makes it compatible with most camping stoves and grills. Includes a practical storage bag.