Safety Information
- Always install the regulator in Gas OFF position only.
- It is recommended that the regulator should be changed every 10 years from the date of manufacture for safe operation.
- For outdoor use, position the device and protect it against direct contact with water.
- Before installation, ensure the rubber gasket in the cylinder valve or regulator is in good condition.
- Make sure all valves on the appliance are turned off.
- Use LPG cylinders in an upright vertical position only.
- Rubber hoses should not be more than 5-10 years old.
- Do not attempt to remove the regulator while the gas is ON.
- Do not move the LPG cylinder while in operation.
- Do not change the LPG cylinder in the presence of candle lights or any naked flames.
- When installing the regulator downstream of another regulator, ensure the supply pressure range is correct for the regulated pressure range of the upstream regulator, plus any pressure losses in the interconnecting pipe work.
- Downstream installation pressure loss shall not exceed the $\Delta \mathrm{P}$ marked on the device.
- If fitting the regulator indirectly to a pressurized tank: The regulator must not be positioned lower than the top of the tank or outlet valve to avoid gas vapor re-liquefying into the regulator. Any additional pipes or hoses must be inclined so that liquefied or condensed gas can drain back into the tank.
Installation
- Check the gasket/seal on the cylinder valve is in place and in good condition. If not, ask your gas dealer to replace the cylinder valve.
- Conduct a visual inspection of the regulator. Remove any dirt or loose metal shavings.
- Fit the gas hose to the regulator outlet nozzle. Use water or liquid soap for lubrication. Insert firmly and clamp with a hose clamp. If the regulator has a threaded outlet, tighten the hose nut to the regulator by hand, then firmly with a wrench. Attach the hose to the gas appliance similarly.
- In the absence of any flame, remove the protection seal or cap from the gas cylinder valve.
- Tighten the regulator hand wheel firmly by hand. No tools are needed.
- Open the regulator knob counter-clockwise, at least one full turn.
- Press the excess flow valve push button on the regulator outlet to fill gas into the hose. Wait 5 seconds.
- Perform a leak test using the manometer gauge. If no leaks, the gas appliance can be started.
- If leaks are detected, check the installation and repeat the leak test procedure.
- To replace the cylinder, turn the gas cylinder valve OFF, then unscrew the regulator.
Gas Level Indicator
Read the current gas level when the gas appliance is in use, using these color indicators:
- Blue: The cylinder is nearly empty, with no more liquid gas.
- Yellow: The cylinder will soon be empty; plan to refill.
- Green: Enough gas for continuous consumption.
Leak Test Procedure
- Connect the regulator to the gas appliance with the gas hose. Ensure gas appliance valves are in the closed/off position.
- Attach the regulator to the gas cylinder valve.
- Open the gas flow by turning the gas cylinder valve control knob.
- After filling the regulator and hose with gas, close the regulator valve again. Gas is now trapped between the regulator and the appliance.
- The manometer dial should move into the Green area of the scale.
- Wait 2-5 minutes. If the dial remains in the green area without moving, the installation is leak-free.
- If the dial moves into the yellow or blue area, the installation has a leak.
- Use leak spray or a soap-water solution to identify the leak.
- Do not use the gas appliance until all leaks are eliminated.
Technical Data
28-30mbar | 50mbar | 28-30mbar | 50mbar | ||
---|---|---|---|---|---|
Model No.: | A500i | $\Delta \mathrm{P} 5$ (mbar): | - | 5 | |
Gas Type: | Butane | Working temperature: | 0-50 deg Celsius | ||
Inlet Pressure (bar): | 0.3-7.5 | Capacity: | 1.5 kg/h | 1.0 kg/h | |
Nominal Outlet Pressure (mbar): | 28-30 | 50 | Inlet connection: | M14, M16, 7/16" | |
$\Delta \mathrm{P} 2$ (mbar): | 2 | - | Outlet connection: | All relevant to EN 16129 |
Contact Information
Integrated Gas Technologies LtD
Gydevang 39-41 - DK3450-Denmark
Email: sales@igt-lpg.com - Website: www.igt-lpg.com
Tel: +45 45769921 - Fax: +45 45769821
CADAC INTERNATIONAL
P.O. Box 43196, Industria, 2042 South Africa
Tel: +27 11 470 6600 Email: info@cadac.co.za www.cadacinternational.com
CADAC UK
14 Deanfield Court, Link59 Business Park, Clitheroe, Lancashire, BB7 1QS United Kingdom.
Tel: +44 (0) 333 2000363
Email: info@cadacuk.com www.cadacinternational.com
CADAC MOZAMBIQUE
Exclusive Brands Africa 492 Avenida Namaacha Maputo, Mozambique
Tel: +258 21 406254 www.cadac.co.mz
CADAC IRAN
Robin Bazarganan Carin Co. Unit D, 6th Floor, Negin Zafar Building, No.1327, Shariati Street, Tehran, Iran
Tel: +98 21 27600781 Mail: info@cadac.ir
CADAC CHINA
Room 807, Huayue International Building, No.255 Tiangao Road, South Yinzhou business district, Ningbo, China
Tel:+86 57487723937
Email: info@cadac.com.cn
CADAC SWEDEN & NORWAY
KAMA FRITID AB
004636353700
info@kamafritid.se
CADAC EUROPE
Ratio 26, 6921 RW Duiven The Netherlands
Tel: +31 263197740 Email: info@cadaceurope.com www.cadacinternational.com
CADAC SCANDINAVIA
Millarco International A/S Rokhøj 26
8520 Lystrup, Denmark
Phone: +4587434200 millarco@millarco.dk www.millarco.com
CADAC MONTENEGRO
City kvart Z1L6
81000 Podgorica, Montenegro
Tel 38220671446, 38269020063
Email: coca@t-com.me
CADAC DENMARK
Camper Fritid
Industrivej 11
6640 Lunderskov, Denmark
Tel.: +45 75585255
Email: info@camper.dk www.camper.dk
CADAC ZIMBABWE
Exclusive Brands Africa Unit 8 Birkenhead Park 43 Josiah Chinamano Street Belmont, Bulawayo
Tel: +263971740 (Bul)
Tel: +2634792564 (Har)
www.cadac.co.zw
CADAC GERMANY
Ratio 26, 6921 RW Duiven The Netherlands
Tel: +31 263197740 Email: info@cadaceurope.com www.cadacinternational.com
CADAC Czech Rep.
RÖSLER Praha spol. s r.o.
K Horkám 19/21
10200 Praha 10 Česká republika
Tel: +420 267188011
Email: info@rosler.cz www.rosler.cz
CADAC FINLAND
OY KAMA FRITID AB
Koivuhaantie 2-4 B
01510 VANTAA
00358207920310
info@kamafritid.fi
CADAC POLAND
Kamai
Wola Batorska 461
32-007 Wola Batorska Poland
Tel: +48 126351373
Email: handlowy@kamai.pl
www.kamai.pl
CADAC ZAMBIA
Exclusive Brands Africa Limited 7225A Kachidza Road Light Industrial Area Lusaka, Zambia
Tel: +260 211842015
Tel: +260977345034
Email: info@ebagrp.com
CADAC FRANCE
Le Viallon, 42520 Veranne France
Tel: +33 474781365
Email : info@cadaceurope.com www.cadacinternational.com
CADAC NEW ZEALAND
Riverlea Group (Pty) Ltd
2A Maui Street, Pukete, Hamilton 3200, New Zealand
Tel: +64 78470204
Email: sales@riverleagroup.co.nz www.riverleagroup.co.nz
CADAC U.A.E.
Supreme Impex General Trading LLC Office No. 1801-7 Latifa Tower Sheikh Zayed Road Dubai, UAE
CADAC ITALY
Brunner SRL/GMBH via Buozzi, 8
39100 Bolzano (Italy)
Tel: +390471542900
Email: info@brunner.it
www.brunnerinternational.com
CADAC SOUTH EAST EUROPE
Bulevar oslobodjenja 285
Tel: +381 113392700
Email: sinisaj@cadac.rs
www.cadac.rs