GSM & WiFi Network Alarm System
User Manual
Wi-Fi+GSM+GPRS
Overall State
Explanation
The icon is only valid for the corresponding model host which is configured with the WIFI module.
The icon is only valid for user who has applied alarm service in the local network alarm operation service center.
Features
- 4.3-inch IPS color display, full capacitive touch screen operation, simple style man-machine interface and menu guidance design.
- The main interface status bar, date and time clock display, host status at a glance.
- Built-in powerful performance CPU master based on 32-bit Cortex-M3 core.
- Based on the operating system with multitasking design, with a great user operation experience.
- WIFI/GSM/GPRS network alarm system, and support APP push/SMS/voice monitoring/center network etc. multi-channel alarm ways, to ensure the alarm performance stable and reliable.
- Support SMS arm/Disarm and parameters setting, support voice arm/Disarm.
- Up to 99 storage locations for the learning of remotes, RFID and wireless detectors. 4 wired defense zones.
- Support many defense zones name such as of the gate, SOS, bedroom, window, balcony, perimeter, smoke, gas, carbon monoxide, water leaking, etc.
- Support the main power failure, backup battery power shortage, tamper alarm and other extended alarm; Support detector low battery alert & tamper alarm function.
- Support Door open alert.
- Support many defense zone types setting such as of entry/exit zone, indoor zone, perimeter zone, 24-hour zone, doorbell, etc.
- Up to 5 groups preset alarm phone numbers, SMS on/off and voice on/off can be set respectively.
- External wired alarm connectors: 1 channel external wireless siren, 8 channel alarm linked wireless intelligent socket.
- APP or host can control several socket, so control the home electrical appliances.
- Can store and query several daily operation records and alarm records.
- GSM network automatic timing, to ensure the clock keep accurately all the time.
- Support multi-language menu display, voice prompts and alarm SMS settings.
- Can record 20 seconds message and alarm voice.
- Telephone function, support 5 groups re-dial number.
- Excellent APP operation feeling and user interface, get the device working status anytime.
- Arm/disarm, host alarm to mobile app.
- Support APP arm/disarm remotely, parameter setting, Parts management and intelligent socket control.
- Friendly APP operating experience and user interface, obtain the latest working state of the device at any time.
- User arm and disarm, host alarm push to APP.
- Support APP arm and disarm remotely.
- GPRS real-time networking online, access to the latest working state of the equipment at any time. Automatically alarm if offline.
- Reserved remote GPRS TCP / UDP protocol channel, compatible with multiple alarm center networking protocol to facilitate network alarm.
- Center remote control.
Daily Operation Nouns
- ARM: set the security task (Anti-burglar), make the host into alert state, also known as Arming, Alert or Booting.
- Stay Arm: When users at home, only need to alert entrances or perimeter.
- Disarm: cancel the safety task (Anti-burglar), also known as removing alarm or shutdown.
- Trigger: In Arm state, detector detects someone or door is opened, it will trigger the detectors and make alarms.
- Exit delay: in the ARM state, to avoid making alarms while the users passing, need to delay the alarm time.
- Entry delay: while the users come back and pass the Arm zones, host will not make alarming immediately, need some time users passing by; the host will make alarms if time out beyond the Disarm.
- Alarm: while the host have the alarm assignment, it will cause the strobe alarm locally, then send the SMS alarm to the mobile defaulted, dial the mobile defaulted, push the alarm to the mobile app and send the message to the networking alarm center etc.
Appearance and Accessories
Front View
The front view displays a touchscreen interface with icons for Call, Money, Security, Disarmed, Normal, Stay Arm, and Disarm. It also shows the time (16:34 and 16:38) and date (2018-02-01 Thursday). A keypad with numbers 0-9 and function buttons like CALL, ARM, SOS, and DISARM is also visible. The screen dimensions are approximately 182mm in height and 112mm in width.
Back View
The back view shows a speaker grille, a microphone, a card slot, a wired defense zone connector, and a USB 5V port. There is also a label indicating a built-in anti-prying switch.
Menu Structure
The menu structure allows for various settings and configurations:
Category | Setting | Function | Details |
---|---|---|---|
Delay Setting | Exit Delay | Set exit delay value | Unit: seconds; scope: 0~999; default: 40 seconds |
Enter Delay | Set enter delay value | Unit: seconds; scope: 0~999; default: 30 seconds | |
Siren Duration | Set siren duration time while alarming | Unit: minutes; scope: 0~999; default: 3 minutes | |
Arm Beep | Set arm beep for external siren while arm/disarm | Scope: on/off, default: off | |
Alarm Beep | Set siren notice for internal/external siren while arm/disarm | Scope: on/off, default: off | |
Arm/Disarm SMS | SMS notice while setting the Arm/disarm | Scope: yes/no, default: no | |
Phone Management | 1st Phone | Group 1 alarm phone number & dial Switch, SMS switch | See Phone Number setting |
2nd Phone | Group 2 alarm phone number & dial Switch, SMS switch | See Phone Number setting | |
3rd Phone | Group 3 alarm phone number & dial Switch, SMS switch | See Phone Number setting | |
4th Phone | Group 4 alarm phone number & dial Switch, SMS switch | See Phone Number setting | |
5th Phone | Group 5 alarm phone number & dial Switch, SMS switch | See Phone Number setting | |
Accessories | Remote Controller | Add/delete remote controller | See Remote controller add/delete |
Detectors | Add/delete wireless detectors | See Wireless detector add/delete | |
RFID | Add/delete RFID cards | See RFID card add/delete | |
Siren Learn | External wireless siren pairing | See External Wireless Siren matching | |
Alarm Socket | Alarm linkage intelligent socket Airlink | See Intelligent Home appliances | |
Timer | Socket Timer | Intelligent socket timer on/off setting | See Intelligent Home |
Record | Record/Playback | See Record management | |
Duration | Set record duration | Scope: 1~20 second; Default: 20 | |
Arm Timer | Arm timer time & on/off setting | See Arm / disarm Timer | |
System Setting | Keyboard Lock | Keyboard locked setting | Scope: yes/no, default: no |
Keyboard Backlight | Keyboard backlight setting | Scope: on/off, default: off | |
Keypad Tone | Keypad Tone setting | Scope: on/off, default: off | |
Initialization | System Initialization | System Initialization | See System Initialization |
Language Setting | Set host language | Multiple languages available: English, Greek, Simplified Chinese, Deutsch, Russian, Spanish, Polish, Italian, French, Portuguese. | |
Password Setting | User Password | User password setting. Scope: 0000~9999; default: 1234 | |
Password Setting | System password | System password setting. Scope: 0000~9999; scope: 6666 | |
Wi-Fi Setting | Host gets into WIFI wireless networking airlink status | See Mobile APP with the host airlink & unbind | |
Wi-Fi Setting | Hotspot | Host gets into WIFI wireless network airlink status | See Mobile APP with the host airlink & unbind |
Initial Usage
Start Operation
Insert Card: Insert a standard micro SIM card into the card slot.
Power On: Plug in the power adapter through the USB 5V interface. Press and hold the power button until 'Welcome' displays on the screen.
Power Off: Press and hold the power button until the screen turns black.
System Initialization
Navigate to Main Menu → System Setting → Initialization. This resets all parameters, languages, and time zones to factory defaults. All learned remote controls, detectors, RFID tags, and records will be deleted. The host will enter GPRS offline status. You may need to send an SMS to reset the IP to go back online.
Caution: Only perform initialization if you forget the operation password, the host malfunctions, parameters are set incorrectly, or detectors/remote controls/RFID tags are unidentified. Initialization does not work under Keypad Lock.
Smart Life APP Quick Use Guide
APP Download
Download the 'Smart Life' APP from major global application stores by searching for 'Smart Life' or scanning the provided QR codes. For iOS, search in the Apple Store. For Android, search in Google Play or scan the provided QR code. Both versions are the same app.
Account Registration and Login
When registering, select the correct country/region and ensure the mobile phone number includes the country code.
Device Network Configuration
The default network configuration is Airlink Configure. You can switch to 'SoftAP Configure' via 'Other Mode'. The mobile phone must be connected to the 2.4GHz Wi-Fi network that the device will use.
Airlink Configure
- Use the Smart Life APP, tap '+' in the upper right corner, then select 'Security & Sensor', then 'Alarm', then 'Wi-Fi', and click OK.
- Enter the correct WiFi password and click 'Next'.
- Wait for the device to enter Airlink Configure mode.
- Follow the on-screen instructions.
- Back in the Smart Life APP, click 'Continue' to complete the network configuration.
SoftAP Configure
- Use the Smart Life APP, tap '+' in the upper right corner, then select 'Security & Sensor', then 'Alarm', then 'Wi-Fi', then 'Other mode', then 'SoftAp Configure', and click OK.
- Enter the correct WiFi password and click 'Next'.
- Wait for the device to enter SoftAP mode.
- Follow the on-screen instructions.
- Back in the Smart Life APP, click 'Continue' to complete the network configuration.
Menu Operation
This product features a touch screen for operation. Refer to the diagrams for features not detailed here.
Adding Alarm Phone Number
The host can be configured with up to 5 phone numbers for dialing and SMS notifications.
- Keypad operation: Main Menu → Phone → 1st Phone. Input the alarm phone number (max. 18 digits).
- Press to enable/disable dialing.
- Press to enable/disable SMS notifications.
- Press to confirm.
Adding/Deleting Remote Controller
Navigate to Main Menu → Parts → Remote controller. Push or for page down to view synchronized remote controllers.
Adding a new remote controller
- Press ✓ to add a remote. A 20-second countdown begins.
- Press any button on the remote to send a wireless signal.
- 'Learning OK' indicates successful addition. 'Device code has been learned' means the remote is already added or has a duplicate code.
Delete
Select the remote controller from the list and press the corresponding number to delete it. Press '0' to delete all.
Match code with/delete wireless detectors
Navigate to Main → menu → Parts → Detector. Press or page down to list synced wireless detectors.
Sync the new wireless detectors
- Press ✓ to enter 'Set Name/Mode/Number'.
- Press to choose the zone name and detector type (Stay Arm Active, Out Arm Active, 24 Hours Active, Close, Doorbell).
- Stay Arm Active: Alarms when triggered in armed or stay armed state. Recommended for doors, windows, perimeter.
- Out Arm Active: Alarms when triggered in armed state, but not in stay armed state. Recommended for interior areas like living rooms, bedrooms.
- 24 Hours Active: Alarms anytime it's triggered. Recommended for SOS, Panic, Smoke, Gas, CO, Water Leakage detectors.
- Close: Does not alarm when triggered.
- Doorbell: Notifies with a 'dingdong' sound when triggered.
- 24 Hours Silent: Alarm sent without siren when detectors are triggered. Recommended for SOS, Panic, Smoke, Gas, CO, Water Leakage detectors.
Pair the wireless Siren
Put the wireless siren into pairing mode (refer to its manual). Press the host's siren pairing code button. The host will show 'code pairing signal already been sent'. The siren will indicate 'pairing succeed'. The host will alarm and the siren will beep simultaneously.
Wireless alarm linkage
Pairing alarm linkage Wireless Socket
Navigate to Menu → Parts → alarm Socket. Operate the wireless socket to enter pairing mode (refer to its manual). Press and hold the switch button until it lights up. Press ↑ to choose on/off. The hub sends signals to the switch. Paired sockets can be controlled by the host, mobile app, or timer.
Intelligent home appliances
- Full Socket: Navigate to the socket interface to control sockets.
- Code Pairing: Follow the instructions in 'socket code paring with the alarm host linkage' to pair sockets.
- Press ↑ or to send on/off signals.
- Sockets can be controlled by the host, APP, or timer.
REMOTE SMS
Set Parameters by SMS
Users can set parameters by sending SMS messages to the host's SIM card. The format is: *[System password]*[Address setting]*[Content setting]*.
One SMS can include multiple settings separated by '*'. Each address should be 2 digits. SMS messages should be less than 160 bytes.
Address | Function | Content & Scope | Factory Setting |
---|---|---|---|
35 | Redial times while dial failure | 1~255 Times | 1 Time |
36 | bell ring times while auto receiving | 1~255 Times | 1 time (in future) |
38 | User name password correct | 0000~9999 must be 4 digits | 1234 |
39 | System password correct | 0000~9999 must be 4 digits | 6666 |
43 | Parameter initialization | See note 1 | Closed |
51 | alarm phone 1st setting | See note 2 | Closed |
52 | alarm phone 2nd setting | See note 2 | Closed |
53 | alarm phone 3rd setting | See note 2 | Closed |
54 | alarm phone 4th setting | See note 2 | Closed |
55 | alarm phone 5th setting | See note 2 | Closed |
62 | Search the GSM field strength | Empty | Ω |
90 | Set the GPRS server IP address | See note 3 | Empty |
92 | Set the GPRS APN | See note 4 | CMNET |
93 | Set domain name of the network time server | us.ntp.org.cn | +8 |
94 | Set the time difference with the standard Greenwich time | +8 |
Setting comment: all the example used the default system password:6666
Note 1: Parameter initialization: keep the learned remote controller, wireless detectors and RFID cards, others recovery to factory setting. Set the SMS content as: *6666*43*.
Note 2: Alarm phone number setting format: xxxxxxxxxxx,A,B. xxxxxxxxxx is the phone number (no more than 18 digits), A: alarm voice dial switch (1-on, 0-off), B: SMS alarm switch (1-on, 0-off).
Note 3: IP address setting format should be: aaa,bbb,ccc,ddd,xxxxx. aaa,bbb,ccc,ddd is the IP address, xxxxx is the port number, use the comma to separate for each address.
Note 4: Set the local GSM operator GPRS access point APN.
Searching system setting:
SMS format: *6666*62*, host echo:
- SYSTEM set: Host serial number
- SN: Host language
- LANGUAGE: Engineer password
- USER PASSWORD: GSM field strength value(0 or 99means the signal unusual)
- WIFI RSSI: WIFI field strength value
Alarm phone number searching setting
SMS format: *6666*51*, host echo:
- PHONE set: 1-5 alarm phone number, voice switch, SMS switch, general switch
- REDIAL COUNTER: voice alarm redial counters
Delay searching setting
SMS format: *6666*33*, host echo:
- DELAY set: delay entering (unit: second)
- ENTRY: delay quit (unit: second)
- EXIT: alarming time (unit: minutes)
- SIREN:
Searching switch setting
SMS format: *6666*46*, host echo:
- SWITCH set:
- ARM/DISARM BEEP: arm/disarm Beep switch (1: on, 0: off)
- ALARM BEEP: alarm beep switch (1: on, 0: off)
- ARM/DISARM SMS: arm/disarm SMS switch (1: on, 0: off)
Learned remote controller & detector quantities
SMS format: *6666*26*, host echo:
- DETECTOR learned: learned remote controller quantities
- REMOTE: learned detectors quantities
- DETECTOR: learned RFID card quantities
- RFID:
PHONE FUNCTION
Push in the main interface to enter the phone number dialing interface. Push to review the dialed phone number. Phone call operation is forbidden under the following conditions: GSM network abnormal, arm/disarm, or phone alarm in progress.
User Daily Operation
Users can operate the alarm host via:
- On-site Remote controller, keyboards, RFID cards.
- Remote SMS
- Mobile phone APP
- GPRS alarm center
Out Arm
- Remote control: Press 【日】 key.
- Keyboard: Main Interface, press to trigger Out Arm.
- RFID tag: In disarm mode, place the RFID card near the sensitive area on the bottom right of the alarm host.
- Remote SMS: Send SMS message '1234#1' (1234 is user password). The host will send 'System Armed!' SMS.
- APP: Main Menu, select 'Out Arm' icon.
Reminder: A voice prompt 'System armed' will be heard. The interface displays 'Armed' and 'Please exit'. An exit time progress bar appears. Leave the alarm zone before the exit time expires. If Arm/Disarm SMS switch is ON, a 'System Armed!' SMS will be received. In Out Arm mode, all defense zones are on alert. Triggering a zone will generate an alarm, send SMS, call preset numbers, and push notifications to the APP/GPRS alarm center. If an alarming leakage smart plug is learned, it will switch on.
Stay Arm
- Remote control: Press 【】 key.
- Keyboard: Main Interface, press to trigger Stay Arm.
- Remote SMS: Send SMS message '1234#3'. The host will send 'System Stay Armed!' SMS.
- APP: Main Menu, select 'Stay Arm' icon.
Reminder: A voice prompt 'System armed' will be heard. The interface displays 'Stay Armed'. If Arm/Disarm SMS switch is ON, a 'System Stay Armed!' SMS will be received. In Stay Arm mode, only valid Stay Arm defense zones are on alert. Triggering a zone will generate an alarm, send SMS, call preset numbers, and push notifications to the APP/GPRS alarm center. If an alarming leakage smart plug is learned, it will switch on.
Disarm
- Remote control: Press 【】 button.
- Keyboard: Press on the main interface.
- RFID tag: In out arm/stay arm mode, place the RFID card near the sensitive area on the bottom right of the alarm host.
- SMS: Send SMS message '1234#2'. The host will send 'System Disarmed!' SMS.
- APP: Main Menu, select 'Disarm' icon.
Reminder: A voice prompt 'System Disarmed' will be heard. The interface displays 'Disarmed'. If Arm/Disarm SMS switch is ON, a 'System Disarmed!' SMS will be received. In Disarm mode, all alarm procedures are terminated. If Arm/Disarm SMS switch is ON, a 'System Stay Armed!' SMS will be received. If an alarming leakage smart plug is learned, it will switch off.
SOS
- Remote control: Press 【SOS】 button.
- Keyboard: Press 【SOS】 on the main interface.
- APP: Select 'SOS' icon in the main menu.
Reminder: The interface displays 'Help'. An alarm sound will be generated, and an alarm SMS will be sent, or preset numbers will be called. Simultaneously, alarm information will be sent to the mobile APP or GPRS alarm center.
Confirm the operation result by SMS
<The alarm host name>: The result of remote operation
ALARM & REMOTE MONITORING
The host supports multiple alarm types. When an alarm occurs, it sends alarm messages with detector name and number to the user's mobile phone, pushes alarm information to the mobile phone APP, and sends alarm information to the monitoring center. It also dials the user's telephone for on-site monitoring and remote control.
The host also supports the following alarm classes
- Main power failure: Alarm is effective 5 seconds after main power failure.
- Anti-prying alarm: Alarm after separation of main engine wall mounting bracket and main engine.
- Spare battery power shortage: Alarm is valid when spare battery voltage is less than 3.45V and lasts for 10 seconds under main power failure.
- Main power recovery.
SMS Alarm
Alarm occurred, host sends SMS to preset phone numbers.
<Host Name>: Current alarm! Defense Zone: xx
Auto Dial Number Setting
When an alarm occurs, the host dials preset phone numbers. After the user answers, it displays the alarm type. If a default recording exists, it provides voice prompts: 'Press 1 is arm, Press 2 is disarm, Press 3 to monitor, Press 4 to talk'. Users can press 2 to disarm and end the alarm progress, or press 3 to close the scene alarm. Hanging up will stop the monitor.
If the user fails to answer or dial, the host will continue to dial preset numbers until the user receives the call.
Preset Telephone Remote Calls Host
When preset telephone numbers call the alarm host, it automatically connects. After connection, the host can monitor the on-site scene or control the host via voice prompts.
Mobile app alarm receiving procedure
When an alarm occurs, the panel sends a push notification to your mobile phone. Check the alarm type in the APP main menu under 'Alarm Info' to view records of panel operations and alarm logs.
Networking Alarm Receiving Procedure
When an alarm occurs, the host sends the alarm message to the network monitoring center via GPRS. Emergency response can be handled quickly by the central police. This function is valid only after the host's user network alarm function and service are enabled. The IP address must be set via SMS. APN must also be set for foreign or other areas. Refer to SMS message setting parameters for details.
Technical Parameters
- Input Voltage: DC5V (Micro USB Standard Interface Power Supply)
- Working Current: <500mA
- Siren Output: <80db in 1 meter
- Wireless Frequency: 433Mhz/2.4G/125K
- Wireless Coding: eV1527
- GSM System: 850/900/1800/1900MHz
- WIFI System: IEEE802.11b/g/n wireless standard
- Spare Battery: 3.7V/1000mAh
- Working Temperature: -10 ~ 55 ℃
- Relative Humidity: < 80% (no condensation)
- Product Size: 182*112*16MM (length x height x thickness)
PACKING LIST
- One set of host with built-in backup battery.
- Micro USB 5V / 2A standard power supply, one set of power cord.
- Mini siren*1
- Screw pack*1
- RFID tags*2
- PIR sensor*1
- Window/door sensor*1
- Remote controller*2
File Info : application/pdf, 13 Pages, 5.23MB
DocumentDocumentRelated Documents
![]() |
GSM & WiFi Alarm System User Manual Comprehensive user manual for the GSM & WiFi Alarm System, covering features, initial setup, daily operation, remote monitoring, and specifications. |
![]() |
Tuya PG-500 GSM 4G WiFi Alarm System User Manual Comprehensive user manual for the Tuya PG-500 GSM, 4G, and WiFi alarm system. Learn about features, installation, app control, settings, and maintenance. |
![]() |
Smart Security System User's Guide Comprehensive user guide for the Tuya Smart Security System, covering setup, component descriptions, installation, operation, features, and specifications. |
![]() |
Tuya App Manual: Guide to Connecting and Managing Smart Access Control Devices Comprehensive guide to using the Tuya app for smart access control devices, covering device setup, user management, code generation, and access logs. Learn how to connect your Wi-Fi Keypad and manage access remotely. |
![]() |
Tuya WBR1 Module Datasheet: Wi-Fi & Bluetooth LE Connectivity Detailed technical datasheet for the Tuya WBR1 module, a low-power embedded Wi-Fi and Bluetooth LE module featuring the W701-VA1-CG chip, suitable for various IoT applications. |
![]() |
Solar Outdoor Infrared Sound and Light Alarm User Manual User manual for the Solar Outdoor Infrared Sound and Light Alarm, detailing setup, app connection via Tuya Smart or Smart Life, network configuration (EZ and AP modes), work mode selection, and installation guidelines. |
![]() |
Tuya Smart Siren Alarm 3-in-1 with Temperature and Humidity Sensor - User Manual Get started with your Tuya Smart Siren Alarm 3-in-1. This guide covers product configuration, specifications, LED status, reset procedures, and how to use the Smart Life app for advanced features like temperature/humidity alerts and device sharing. |
![]() |
WIFI Switch Module 1CH, 2CH, 3CH, 4CH: Instruction Manual & Installation Guide This manual provides detailed instructions for installing and operating the 1CH, 2CH, 3CH, and 4CH Wi-Fi Switch Modules. It covers technical specifications, safety warnings, wiring diagrams for various configurations, a comprehensive FAQ section, and a guide to using the Tuya Smart App for smart home automation. |