Hisense Use and Installation Instructions

Models: AP1019CW1G, AP1219CR1W, AP1419CR1G, AP1419CW1G, AP1319HR1G

For questions about features, operation/performance, parts or service, call: 1-877-465-3566

Air Conditioner Safety

Your safety and the safety of others is very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

Safety Alert Symbol: ⚠️ This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING".

DANGER: A hazard that if not avoided will result in death or serious injury.

WARNING: A hazard that if not avoided could result in death or serious injury.

All safety messages will tell you what the potential hazard is and tell you how to reduce the chance of injury.

Important Safety Instructions

WARNING: To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow these basic precautions:

  • Plug into a grounded 3 prong outlet.
  • Do not remove ground prong.
  • Do not use an electrical adapter.
  • Do not use an extension cord.
  • Unplug air conditioner before servicing.
  • Use two or more people to move and install air conditioner.
  • The appliance is not intended for use by young children or impaired persons without supervision. Young children should be supervised to ensure that they do not play with the appliance.

SAVE THESE INSTRUCTIONS

Storage and Disposing of the Unit

Please recycle or dispose of the packaging material for product in an environmentally responsible manner. Never store or ship the air conditioner upside down or sideways to avoid damage to the compressor. Dispose of this appliance in accordance with Federal and Local regulations. Refrigerants must be evacuated before disposal.

Installation Requirements

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Tools Needed:

  • Phillips screwdriver
  • Scissors
  • Pencil
  • Cordless drill and 1/4" bit

Parts Supplied:

Check that all parts are included in parts package.

  • A. Foam seal
  • B. Coupling
  • C. Flexible exhaust hose
  • D. Window exhaust adapter
  • E. Rivets (4)
  • F. Screws (4)
  • G. Window-lock bracket (2)
  • H. Outer slider section with vent
  • I. Inner slider section-short
  • J. Inner slider section
  • K. Outer slider section
  • L. Foam seal-long (2)
  • M. Foam seal-short (2)
  • N. Drain hose clip (Heat pump models)
  • O. Drain hose (Heat pump models)

Electrical Requirements

WARNING ⚠️ Electrical Shock Hazard

Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock.

Wiring Requirement:

  • 115 V (103.5 min. to 126.5 max.)
  • 15 A time-delay fuse or circuit breaker

Power Supply Cord:

This portable air conditioner is equipped with a power supply cord required by UL. This power supply cord contains state-of-the-art electronics that sense leakage current. If the cord is crushed, the electronics detect leakage current and power will be disconnected in a fraction of a second.

To test your power supply cord:

  1. Plug power supply cord into a grounded 3 prong outlet.
  2. Press RESET (on some devices, a green light will turn on).
  3. Press TEST (listen for click; Reset button will trip, and on some devices, a green light will turn off).
  4. Press and release RESET (listen for click; Reset button will latch, and on some devices, a green light will turn on). The power supply cord is ready for operation.

NOTE: The Reset button must be pushed in for proper operation. The power supply cord must be replaced if it fails to trip when the test button is pressed or fails to reset. Do not use the power supply cord as an off/on switch. The power supply cord is designed as a protective device. A damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and must not be repaired. The power supply cord contains no user serviceable parts. Opening the tamper-resistant case voids all warranty and performance claims.

Recommended Grounding Method:

This portable air conditioner must be grounded. The cord must be plugged into a mating, grounded three-prong outlet, grounded in accordance with all local codes and ordinances. If a mating outlet is not available, it is the customer's responsibility to have a properly grounded three-prong outlet installed by a qualified electrical installer.

It is the customer's responsibility:

  • To contact a qualified electrical installer.
  • To assure that the electrical installation is adequate and conforms to the Nation Electrical Code, ANSI/NFPA 70-last edition, and all local codes and ordinances.

Copies of the standards listed may be obtained from: Nation Fire Protection Association, 1 Batterymarch Park, Quincy, Ma 02169-7471, www.nfpa.org

Location Requirements

The flexible exhaust hose allows placement of the air conditioner at least 20" from window or door. Confirm you are using the correct size air conditioner for the space to be cooled, per sizing recommendations, below:

NOTE: Match BTUs to room use and location:

  • Shaded room reduce to next smaller size
  • Sunny room increase to next larger size
  • For kitchens, increase to next larger size
Area to be cooledDOE Capacity needed (BTUs)
Up to 10'x 20' Room (200 sq ft.)5,000/5,500
Up to 15'x 20' Room (300 sq ft.)6,000/6,500
Up to 20' x 20'Room (400 sq ft.)7,000/7,500
Up to 20' x 25' Room (500 sq ft.)8,000/8,500
Up to 20' x 30' Room (600 sq ft.)9,000/9,500

Installation Instructions

Unpack the Air Conditioner

WARNING ⚠️ Excessive Weight Hazard

Use two or more people to move and install air conditioner. Failure to do so can result in back or other injury.

  • Do not use sharp instruments, rubbing alcohol, flammable fluids, or abrasive cleaners to remove tape or glue. These products can damage the surface of your air conditioner.
  • Handle the air conditioner gently.
  • Keep unit upright at least 2 hours prior to use.

Remove packaging materials:

  • Remove and recycle packaging materials.
  • Remove tape and glue residue from surfaces before turning on the air conditioner. Rub a small amount of liquid dish soap over the adhesive with your fingers. Wipe with warm water and dry.

Caution: Installation accessories are stored in the top of the carton, and are required for proper cooling performance. Please remove all accessories from packing materials before use.

Window Vent Panel And Extensions

The window installation kit allows you to install the air conditioner in most vertical-sliding windows 18" to 50" wide, or horizontal sliding windows from 18" to 50" high.

Panel Length vs. Window Length:

Panel LengthHIJKWindow Length
18"9 11/16"18"18"18"
19"-26"a
27"-34"b
35"-50"c

1. Check your window size and choose the fit from the above table.

2. If your window size requires more than 2 panels, after adjusting the length, please secure the panels with rivets, E.

Panel Assembly Examples:

For an 18" window opening: Use the window vent panel (Panel H) by itself. (See Figure "a")

For window openings from 19" to 26": Use the window vent panel (Panel H) and an extension panel (Panel I). (See Figure "b")

For window openings from 27" to 34": Use the window vent panel (Panel H) and an extension panel (Panel J). (See Figure "c")

For window openings from 35" to 50": Use the window vent panel and two extension panels (Panel K and Panel J). (See Figure "d")

Install The Portable Air Conditioner

Install Exhaust Hose and Adapter

  1. Roll the air conditioner to selected location. See "Location Requirements" in page 4.
  2. Prepare the exhaust hose assembly: Press the flexible exhaust hose into the coupling and the window exhaust adapter. Both the coupling and window exhaust adapter have integral clips that snap onto the hose.

Window Installation

Your window installation kit has been designed to fit most standard vertical and horizontal window applications. Roll the air conditioner to selected location. See "Location Requirements" in page 4.

  1. Attach the window exhaust adapter to the outer slider section (the piece with the large exhaust hole).

NOTE: Product must be used with included Duct Window installation kit for effective cooling.

  • Insert the coupling into the slot on the back of the air conditioner.
  • Slide down to lock the hose into place.
  • Confirm the hose is locked in place before operating.

Installation In Vertical Sliding Windows

NOTE: The window installation kit can be used with vertical sliding windows between 18" and 50" wide.

  1. Cut the foam seal L (adhesive type) & M (adhesive type-shorter) to the proper length, and attach it to the window sash and frame.
  2. Insert the vent panel assembly, including extension panels, if needed, into the window opening. Extend the extension panels to the window width.
  3. Cut the foam seal A (non-adhesive type) to the window width. Stuff the foam seal A between the glass and the window to prevent air and foreign objects from getting into the room.
  4. Install the Window-lock bracket with a type F screw as shown if you need.
  5. Insert the window exhaust adapter into the opening in the vent panel. Align the tabs on the window exhaust adapter with the slots in the vent panel. Insert the window exhaust adapter into the opening in the vent panel. Insert the screw in the hole in the window exhaust adapter to prevent the window exhaust adapter from sliding out of the vent opening.

Installation In Horizontal Sliding Windows

NOTE: The window installation kit can be used with horizontal sliding windows between 18" and 50" wide.

  1. Cut the foam seal L (adhesive type) & M (adhesive type-shorter) to the proper length, and attach it to the window sash and frame.
  2. Insert the vent panel assembly, including extension panels, if needed, into the window opening. Extend the extension panels, if used.
  3. Cut the foam seal A (non-adhesive type) to the window width. Stuff the foam seal A between the glass and the window to prevent air and foreign objects from getting into the room.
  4. Install the Window-lock bracket with a type F screw as shown if you need.
  5. Insert the diffuser into the opening in the vent panel and slide it to secure it in place. Align the tabs on the diffuser with the slots in the vent panel. Insert the diffuser into the opening in the vent panel. Insert the screw in the hole in the diffuser to prevent the diffuser from sliding out of the vent opening.

Portable Air Conditioner Use

Operating your portable air conditioner properly helps you to obtain the best possible results. This section explains proper air conditioner operation.

Important Operation Notes:

  • Do not stay in direct airflow from the air conditioner for extended periods of time.
  • Never use in tightly enclosed spaces. Always ensure there is sufficient airflow of outside air entering the household, especially when used in conjunction with combustible devices such as gas stoves, fireplaces, furnaces, hot water heaters etc. Do not place the power cord or air conditioner near a heater, radiator, stoves or other apparatus (including amplifiers) that produce heat.
  • This air conditioner is intended for household use as a residential appliance. Do not use it as a precision climate control for commercial use, or for precision equipment, food, pets, plants, artwork, etc.
  • Do not block or obstruct the exhaust vent hose as it may severely affect performance, or cause failure of the air conditioner.
  • The air conditioner display shows the current room temperature.
  • When changing modes while the air conditioner is in operation, the compressor will stop for 3 to 5 minutes before restarting. If a button is pressed during this time, the compressor will not restart for another 3 to 5 minutes.
  • In Cooling or Dry mode, the compressor and condenser fan will stop when the room temperature reaches the set temperature.
  • On Dry mode, the humidity level is automatically set, but is not able to be displayed.

NOTE: In the event of a power failure, your air conditioner will operate at the previous settings when the power is restored.

Starting Your Portable Air Conditioner

Control Panel:

The control panel includes buttons for Power, Mode, Fan speed, Timer, Sleep, and Dimmer. The display shows the current mode, fan speed, and temperature.

Power On or Off:

Press the POWER button to turn the unit ON or OFF.

NOTE: Keep upright at least 2 hours before use to prevent damaging the compressor. The first time the air conditioner is plugged in and turned on after purchase, it will be set in Cool Mode. When the air conditioner is turned on at all other times, it will run according to the previous setting.

Mode Selection:

  1. Press and release MODE until you see the symbol for the desired setting.
  2. Choose Cool, Dry, Fan, or Heat.
  • Cool: Cools the room. Press FAN to select High, Mid, or Low speeds. Press the Plus or Minus button to adjust the temperature.
  • Dry: Dries the room. The air conditioner automatically selects the temperature. The fan runs on Low speed only. Dehumidification ranges between 2 to 3 pints per hour, by model.
  • Fan Only: Press FAN to select High, Mid, or Low speed.
  • Heat (Optional): Heats the room. Press FAN to select High, Mid, or Low speeds. Press the PLUS or MINUS button to adjust the temperature.

NOTE: Dry mode should not be used to cool the room. Heating is NOT available for cooling only models.

Fan Speed:

  1. Press and release FAN to choose the desired fan speed.
  2. Choose High, Mid, or Low.
  • High: for maximum fan speed
  • Mid: for normal fan speed
  • Low: for minimum fan speed

Temperature Adjustment:

Press the PLUS button to raise the temperature. Press the PLUS button once to increase the set temperature by 1°F (1°C).

Press the MINUS button to lower the temperature. Press the MINUS button once to decrease the set temperature by 1°F (1°C).

Change display between °F and °C: To change the temperature display between °F and °C, press both the Plus and Minus Adjust buttons at the same time.

ION (Optional):

Press the ION button to start or stop the Plasma Generator. When the ION indicator light of the appliance flashes, the Plasma Generator will turn on.

Using the Remote Control

Insert the Batteries:

  1. Remove the battery cover along the arrowed direction.
  2. Insert new batteries making sure that the (+) and (-) of battery are matched correctly.
  3. Re-attach the cover by sliding it back into position.

NOTE: Use 2 standard AAA (1.5volt) batteries. Do not use rechargeable batteries. Replace batteries with new ones of the same type when the display becomes dim, or after 6 months. When replacing batteries, always replace both batteries with new batteries. Do not mix old and new batteries. Do not mix alkaline, standard (carbon-zinc), or rechargeable (ni-cd, ni-mh, etc) batteries. If the air conditioner will not be used for an extended period of time, remove the batteries from the remote.

CAUTION: Do not use the remote if the batteries have leaked. The chemicals in batteries could cause burns or other health hazards.

Storage Tip:

The holder on the back of the unit can be used to store the remote control.

How to Use:

To operate the room air conditioner, aim the remote control at the signal receptor. The remote control will operate the air conditioner at a distance of up to 23' (7m) when pointing at the signal receptor of the air conditioner.

Remote Control Details:

The remote control has buttons for ON/OFF, MODE, FAN, SWING, TIMER, DIMMER, UP, DOWN, and Sleep. The LCD display shows various indicators for cooling, dry, fan only, heating, fan speeds, sleep mode, signal transmission, timer settings, current time, and temperature settings.

NOTE: Press and hold the MODE button on the remote for 5 seconds to switch the temperature display from degrees Fahrenheit (°F) to degrees Celsius (°C).

DIMMER Mode:

Press the DIMMER button to turn off the control panel display. In DIMMER mode, new control inputs will return the display to normal.

Sleep Mode:

SLEEP mode can only be set in Cooling, Heating, or Drying modes. In sleep mode, the unit utilizes lower, quieter fan speeds and automatic temperature adjustments offering 8 hours of optimal sleeping conditions before shutting off.

NOTE: The appliance will stop operation automatically after operating for 8 hours. Fan speed is automatically set at low speed. In Cooling mode, if the current room temperature is below 79°F (26°C), the temperature will automatically increase 1°F (1°C) during the first hour after Sleep control is activated. If the room temperature is 79°F (26°C) or above, the set temperature will not change. In Heating mode, the set temperature will decrease by 6°F (3°C) at most, during 3 hours, and continues running at that temperature until auto shut off.

  1. Press MODE to select COOL, HEATING, or DRY. (Sleep control cannot be selected in Fan mode.)
  2. Press the UP or DOWN button to set the temperature.
  3. Press and hold the DIMMER button on the remote for 5 seconds to switch from DIMMER mode to Sleep mode.
  4. After 5 seconds, the lights on the control panel display will dim.
  5. To turn off Sleep control, press MODE, FAN, Sleep, or wait 8 hours for Sleep control to turn off automatically.

NOTE: The air conditioner will return to previous settings after Sleep mode is turned off.

TIMER Function:

Use the TIMER function to turn the air conditioner ON/OFF automatically.

Setting the Air Conditioner to Turn ON:

  1. Plug in the air conditioner and use the remote to power it ON.
  2. Use the remote to set the desired mode, temperature, fan speed, etc.
  3. Use the remote to power OFF the air conditioner.
  4. Press TIMER on the remote and use the UP, DOWN buttons to set the desired delay time until the air conditioner turns ON. The delay time can be set from 0 to 24 hours in one-hour increments.
  5. Press TIMER again to confirm the delay time. The TIMER light on the unit will be on.

Setting the Air Conditioner to Turn OFF:

  1. Plug in the air conditioner and use the remote to power it ON.
  2. Use the remote to set the desired mode, temperature, fan speed, etc.
  1. Press TIMER on the remote and use the UP, DOWN buttons to set the desired delay time until the air conditioner turns OFF. The delay time can be set from 0 to 24 hours in one-hour increments.
  2. Press TIMER again to confirm the delay time. The TIMER light on the unit will be on.

To cancel TIMER: Press the TIMER button again. Once a "beep" is heard and the indicator disappears, the TIMER mode has been canceled.

NOTE: The TIMER function can only be set by the remote control.

SWING Function:

Press SWING once to change the vertical airflow direction. Press again to hold the louver in a desired position.

NOTE: Airflow is automatically adjusted to a preset direction after turning on the unit. The direction of airflow can be adjusted by pressing the SWING button. Do not turn the airflow louvers manually; to prevent damage, turn off the unit first and cut off the power supply. Then restore power again after adjustment.

Normal Sounds:

When your air conditioner is operating normally, you may hear sounds such as:

  • Air movement from the fan.
  • Clicks from the thermostat cycling.
  • Vibration or noise due to poor wall or window construction.
  • A high-pitched hum or pulsating noise caused by the high-efficiency compressor cycling on and off.

Portable Air Conditioner Care

Draining the Air Conditioner (non-Heating models)

WARNING: Please connect the drain hose on heating mode, or the unit will stop running after the water reaches warning level.

  1. Uncover the primary drain port.
  2. Attach the drain hose to the primary drain hose. Make sure the connector has no water leak.
  3. Place the other end of drain hose into an outfall. Check to see that the hose lies flat and is in the drain. Make sure the hose end that goes to the drain is on a lower level than the hose end that connects to the unit. The hose should not be kinked or pinched.

Draining the Air Conditioner (Heating models)

WARNING: Please connect the drain hose on heating mode, or the unit will stop running after the water reaches warning level.

  1. Uncover the primary drain port.
  2. Attach the drain hose to the primary drain hose. Make sure the connector has no water leak.
  3. Place the other end of drain hose into an outfall. Check to see that the hose lies flat and is in the drain. Make sure the hose end that goes to the drain is on a lower level than the hose end that connects to the unit. The hose should not be kinked or pinched.

Cleaning the Outside:

  1. Press ON/OFF to turn off the air conditioner.
  2. Unplug the air conditioner or disconnect power.
  3. Remove the air filter and clean separately. See "Cleaning the Air Filter".
  4. Wipe the outside of the air conditioner with a soft, damp cloth.
  5. Plug in the air conditioner or reconnect power.
  6. Press ON/OFF to start the air conditioner.

Cleaning the Air Filter:

  1. Press ON/OFF to turn off the air conditioner.
  2. Open the filter panel door on the back of the air conditioner and remove.
  3. Remove the tapping screw from the condenser air intake filter panel door and remove.
  4. Use a vacuum cleaner to clean the filter. If the filter is very dirty, wash the filter in warm water with a mild detergent.

NOTE: Do not wash the filter in the dishwasher or use any chemical cleaners.

  1. Air dry the filter completely before replacing to ensure maximum efficiency.
  2. Reattach the air filter to the filter panel door.
  3. Reinstall the filter panel door and tapping screw.
  4. Press ON/OFF to start the air conditioner.

Storing After Use:

If the air conditioner will not be used for an extended period of time:

  1. Drain the water completely. See "Draining the Air Conditioner".
  2. Run the air conditioner set to Fan Only for approximately 12 hours to dry the air conditioner.
  3. Unplug the air conditioner.
  4. Remove the flexible exhaust hose and store with the air conditioner in a clean, dry area. See "Installation Instructions".
  5. Remove the window kit and store with the air conditioner in a clean, dry area. See "Installation Instructions".
  6. Remove the filter and clean. See Cleaning the Air Filter.
  7. Clean the outside of the air conditioner. See "Cleaning the Outside".
  8. Reinstall the filter.
  9. Remove the batteries and store the remote control with the air conditioner in a clean, dry area.

Before using the air conditioner again:

  1. Make sure the filter and drain cap are in place.
  2. Check the power cord to make sure it is in good condition, with no cracks or damage.
  3. Place new batteries in the remote.
  4. Install the air conditioner. See "Installation Instructions".

Troubleshooting

Before calling for service, please try the suggestions below.

Air conditioner will not operate

WARNING ⚠️ Electrical Shock Hazard

Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock.

  • The power supply cord is unplugged. Plug into a grounded 3 prong outlet. See "Electrical Requirements".
  • A time-delay fuse or circuit breaker of the wrong capacity is being used. Replace with a time-delay fuse or circuit breaker of the correct capacity. See "Electrical Requirements".
  • The power supply cord has tripped (Reset button has popped out). Press and release RESET (listen for click; Reset button will latch and remain in) to resume operation.
  • A household fuse has blown, or a circuit breaker has tripped. Replace the fuse, or reset the circuit breaker. See "Electrical Requirements".
  • The On/Off button has not been pressed. Press ON/OFF.
  • The local power has failed. Wait for power to be restored.

Air conditioner blows fuses or trips circuit breakers

  • Too many appliances are being used on the same circuit. Unplug or relocate appliances that share the same circuit.
  • You are trying to restart the air conditioner too soon after turning off air conditioner. Wait at least 3 minutes after turning off air conditioner before trying to restart the air conditioner.

Air conditioner power supply cord trips (Reset button pops out)

  • Disturbances in your electrical current can trip (Reset button will pop out) the power supply cord. Press and release RESET (listen for click; Reset button will latch and remain in) to resume operation.
  • Electrical overloading, overheating, cord pinching or aging can trip (Reset button will pop out) the power supply cord. After correcting the problem, press and release RESET (listen for click; Reset button will latch and remain in) to resume operation. If the power cord fails to reset, contact a service technician.

NOTE: A damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and must not be repaired.

Air conditioner seems to run too much

  • Is there a door or window open? Keep doors and windows closed.
  • The current air conditioner replaced an older model. The use of more efficient components may cause the air conditioner to run longer than an older model, but the total energy consumption will be less. Newer air conditioners do not emit the "blast" of cold air you may be accustomed to from older units, but this is not an indication of lesser cooling capacity or efficiency. Refer to the efficiency rating (EER) and capacity rating (in Btu/h) marked on the air conditioner.
  • The air conditioner is in a heavily occupied room, or heat-producing appliances are in use in the room. Use exhaust vent fans while cooking or bathing and try not to use heat-producing appliances during the hottest part of the day. Portable air conditioners are designed as supplemental cooling to local areas within a room. A higher capacity air conditioner may be required, depending on the size of the room being cooled.

Air conditioner runs for a short time only, but room is not cool

  • Set temperature is close to room temperature. Lower set temperature. See "Portable Air Conditioner Use".

Display error code

If the unit displays error code E5, the water container is full. Drain the water, see "Draining the air conditioner". After draining, the unit can be operated again.

If the unit displays error code E1/E2/E3/E4/E6/E7/E9/EA, please contact customer service.

Air conditioner runs, but does not cool

  • The filter is dirty or obstructed by debris. Clean the filter.
  • Air outlet is blocked. Clear air outlet.
  • Set temperature is too high. Lower set temperature.

Air conditioner cycles on and off too much

  • The air conditioner is not properly sized for your room. Check the cooling capabilities of your portable air conditioner. Portable air conditioners are designed as supplemental cooling to local areas within a room.
  • The filter is dirty or obstructed by debris. Clean the filter.
  • There is excessive heat or moisture, open container cooking, showers, etc. in the room. Use a fan to exhaust heat or moisture from the room. Try not to use heat-producing appliances during the hottest part of the day.
  • The louvers are blocked. Install the air conditioner in a location where the louvers are free from curtains, blinds, furniture, etc.

PDF preview unavailable. Download the PDF instead.

frwfvxgbiigv CorelDRAW (C) 2018 Retailer Web Services LLC, all rights reserved.

Related Documents

Preview Hisense Portable Air Conditioner Use and Installation Instructions
Comprehensive guide for the installation, operation, and care of Hisense portable air conditioners, including model numbers AP1019CW1G, AP1219CR1W, AP1419CR1G, AP1419CW1G, and AP1319HR1G.
Preview Hisense Portable Air Conditioner Use and Installation Instructions
Comprehensive guide for installing, operating, and maintaining your Hisense portable air conditioner. Includes safety precautions, troubleshooting tips, and care instructions.
Preview Hisense AP1019CR1G Portable Air Conditioner User Manual and Installation Guide
Comprehensive guide for the Hisense AP1019CR1G portable air conditioner, covering safety, installation, operation, care, and troubleshooting. Learn how to set up and use your unit effectively.
Preview Hisense KFR-2601GW/BPE KFR-2801GW/BPE Split Type Air Conditioner Instruction Manual
This instruction manual provides detailed information on the features, operation, installation, care, and troubleshooting of Hisense KFR-2601GW/BPE and KFR-2801GW/BPE split type air conditioners.
Preview Hisense AP1319HR1G Portable Air Conditioner with Heat Pump - Features and Specifications
Discover the Hisense AP1319HR1G portable air conditioner, featuring 7,500 BTU cooling, 10,500 BTU heating, and multiple modes for year-round comfort. Ideal for spaces up to 400 sq ft, it offers quiet operation, a convenient window kit, and a 2-year warranty.
Preview Hisense AHTP0825UW1W Use and Installation Manual
This manual provides comprehensive instructions for the use and installation of the Hisense AHTP0825UW1W portable air conditioner. It covers safety precautions, pre-installation steps, installation procedures for various window types, operation details, troubleshooting tips, and care and cleaning guidelines.
Preview Hisense AP12NXG Portable Air Conditioner User Manual and Installation Guide
Comprehensive guide for installing, operating, and maintaining the Hisense AP12NXG portable air conditioner. Includes safety instructions, troubleshooting, remote control usage, and care tips.
Preview Hisense HAP0824TWD Portable Air Conditioner: Use and Installation Manual
Comprehensive guide for installing, operating, and maintaining your Hisense HAP0824TWD portable air conditioner. Includes safety precautions, troubleshooting, and care instructions.