Product Overview
Product Brand Name: SIRIUS
Product Designation: Motor management system
Design of the Product: basic unit 3
Product Type Designation: SIMOCODE pro V PN
Description: Basic device SIMOCODE pro V PN, Ethernet/PROFINET IO, PN system redundancy, OPC UA server, web server, transfer rate 100 Mbps, 2 x bus connection via RJ45, 4 I/3 O freely configurable, Us: 24 V DC, input for thermistor connection, monostable relay outputs, expandable by expansion modules.
Detailed Technical Specifications
Vibration and Switching Capacity
Parameter | Value |
---|
Vibration resistance | 1-6 Hz / 15 mm; 6-500 Hz / 2g |
Switching capacity current of NO contacts (AC-15) | |
• at 24 V | 6 A |
• at 120 V | 6 A |
• at 230 V | 3 A |
Switching capacity current of NO contacts (DC-13) | |
• at 24 V | 2 A |
• at 60 V | 0.55 A |
• at 125 V | 0.25 A |
Parameter | Value |
---|
Mechanical service life (operating cycles) typical | 10,000,000 |
Electrical endurance (operating cycles) typical | 100,000 |
Buffering time in event of power failure | 0.02 s |
Reference code (IEC 81346-2) | F |
Continuous current of NO contacts (relay outputs) | |
• at 50 °C | 6 A |
• at 60 °C | 5 A |
Parameter | Value |
---|
Type of input characteristic | Type 1 in accordance with EN 61131-2 |
Substance Prohibitance (Date) | 03/01/2017 |
SVHC substance name | Lead-7439-92-1, Lead monoxide (lead oxide) - 1317-36-8, 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one - 71868-10-5 |
Weight | 0.326 kg |
Electromagnetic Compatibility (EMC)
Parameter | Value |
---|
EMC emitted interference (IEC 60947-1) | class A |
EMC immunity (IEC 60947-1) | corresponds to degree of severity 3 |
Conducted interference (burst, IEC 61000-4-4) | 2 kV (power ports) / 1 kV (signal ports) |
Conducted interference (conductor-earth surge, IEC 61000-4-5) | 2 kV |
Conducted interference (conductor-conductor surge, IEC 61000-4-5) | 1 kV |
Conducted interference (high-frequency radiation, IEC 61000-4-6) | 10 V |
Field-based interference (IEC 61000-4-3) | 10 V/m |
Electrostatic discharge (IEC 61000-4-2) | 6 kV contact discharge / 8 kV air discharge |
Conducted HF interference emissions (CISPR11) | corresponds to degree of severity A |
Field-bound HF interference emission (CISPR11) | corresponds to degree of severity A |
Inputs/Outputs
Parameter | Value |
---|
Parameterizable inputs | Yes |
Parameterizable outputs | Yes |
Number of inputs | 4 |
• For thermistor connection | 1 |
Number of digital inputs with common reference potential | 4 |
Digital input version (Type 1 acc. to IEC 61131) | Yes |
Input voltage at digital input (DC rated value) | 24 V |
Number of outputs | 3 |
Number of semiconductor outputs | 0 |
Number of outputs as contact-affected switching element | 3 |
Switching behavior | Monostable |
Number of relay outputs | 3 |
Type of relay outputs | Monostable |
Wire length for digital signals (maximum) | 300 m |
Wire length for thermistor connection | |
• with conductor cross-section = 0.5 mm² maximum | 50 m |
• with conductor cross-section = 1.5 mm² maximum | 150 m |
• with conductor cross-section = 2.5 mm² maximum | 250 m |
Protective and Monitoring Functions
Function | Status |
---|
Asymmetry detection | Yes |
Blocking current evaluation | Yes |
Power factor monitoring | Yes |
Ground fault detection | Yes |
Ground-fault monitoring | No |
Phase failure detection | Yes |
Phase sequence recognition | Yes |
Voltage detection | Yes |
Monitoring of number of start operations | Yes |
Overvoltage detection | Yes |
Overcurrent detection 1 phase | Yes |
Undervoltage detection | Yes |
Undercurrent detection 1 phase | Yes |
Active power monitoring | Yes |
Motor Control Functions
Function | Status |
---|
Current detection | Yes |
Overload protection | Yes |
Evaluation of thermistor motor protection | Yes |
Parameter | Value |
---|
Total cold resistance (number of sensors in series maximum) | 1.5 kΩ |
Response value of thermoresistor | |
• of the short-circuit control | 3400 ... 3800 Ω |
Release value of thermoresistor | 9 Ω |
• for short-circuit control | 1500 ... 1650 Ω |
Motor Control Functions (Continued)
Function | Status |
---|
Parameterizable overload relay | Yes |
Circuit breaker control | Yes |
Direct start | Yes |
Reverse starting | Yes |
Star-delta circuit | Yes |
Star-delta reversing circuit | Yes |
Dahlander circuit | Yes |
Dahlander reversing circuit | Yes |
Pole-changing switch circuit | Yes |
Pole-changing switch reversing circuit | Yes |
Slide control | Yes |
Valve control | Yes |
Communication / Protocol
Protocol | Supported |
---|
PROFIBUS DP protocol | No |
PROFINET IO protocol | Yes |
PROFIsafe protocol | Yes |
Modbus RTU | No |
EtherNet/IP | No |
OPC UA Server | Yes |
LLDP | Yes |
Address Resolution Protocol (ARP) | Yes |
SNMP | Yes |
HTTPS | Yes |
NTP | Yes |
Media Redundancy Protocol (MRP) | Yes |
Communication Product Functions
Function | Status |
---|
Web server | Yes |
Shared device | Yes |
At the Ethernet interface Autocrossover | Yes |
At the Ethernet interface Autonegotiation | Yes |
At the Ethernet interface Autosensing | Yes |
Media Redundancy Protocol for Planned Duplication (MRPD) | Yes |
Supported Device Level Ring (DLR) | No |
Supported PROFINET system redundancy (S2) | Yes |
Parameter | Value |
---|
Supports PROFIenergy measured values | Yes |
Supports PROFIenergy shutdown | Yes |
Transfer rate maximum | 100 Mbit/s |
PROFINET conformity class | C |
Identification & Maintenance Function
Function | Status |
---|
I&M0 - device-specific information | Yes |
I&M1 - higher level designation/location designation | Yes |
I&M2 - installation date | Yes |
I&M3 - comment | Yes |
Parameter | Value |
---|
Type of electrical connection of the communication interface | 2x RJ45 |
Installation / Mounting / Dimensions
Parameter | Value |
---|
Mounting position | any |
Fastening method | screw and snap-on mounting |
Height | 111 mm |
Width | 45 mm |
Depth | 124 mm |
Required spacing - top | 40 mm |
Required spacing - bottom | 40 mm |
Required spacing - left | 0 mm |
Required spacing - right | 0 mm |
Connections / Terminals
Parameter | Value |
---|
Product component removable terminal for auxiliary and control circuit | Yes |
Type of electrical connection (for auxiliary and control circuit) | screw-type terminals |
Type of connectable conductor cross-sections | |
• Solid | 1x (0.5 ... 4.0mm²), 2x (0.5 ... 2.5 mm²) |
• Finely stranded with core end processing | 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) |
• For AWG cables solid | 1x (20 ... 12), 2x (20 ... 14) |
• For AWG cables stranded | 1x (20 ... 14), 2x (20 ... 16) |
Tightening torque with screw-type terminals | 0.8 ... 1.2 N·m |
Tightening torque [lbf·in] with screw-type terminals | 7 ... 10.3 lbf·in |
Ambient Conditions
Parameter | Value |
---|
Installation altitude at height above sea level | |
• 1 maximum | 2000 m |
• 2 maximum | 3000 m; max. +50 °C (no protective separation) |
• 3 maximum | 4000 m; max. +40 °C (no protective separation) |
Ambient temperature - during operation | -25 ... +60 °C |
Ambient temperature - during storage | -40 ... +80 °C |
Ambient temperature - during transport | -40 ... +80 °C |
Environmental category (during operation acc. to IEC 60721) | 3K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 |
Environmental category (during storage acc. to IEC 60721) | 1K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2 (sand must not get into the devices), 1M4 |
Environmental category (during transport acc. to IEC 60721) | 2K2, 2C1, 2S1, 2M2 |
Relative humidity - during operation | 5 ... 95% |
Contact rating of auxiliary contacts according to UL | B300 / R300 |
Short-circuit Protection
Parameter | Value |
---|
Design of short-circuit protection per output | Fuse links: gG 6 A, quick-response 10 A (IEC 60947-5-1), miniature circuit-breaker C char.: 1.6 A (IEC 60947-5-1) or 6 A (I_K < 500 A) |
Electrical Safety
Parameter | Value |
---|
Touch protection against electrical shock | finger-safe |
ATEX
Parameter | Value |
---|
Certificate of suitability - IECEx | Yes; IECEx BVS 20.0020 / IECEx PTB 18.0004X |
Certificate of suitability - according to ATEX directive 2014/34/EU | BVS 06 ATEX F001, PTB 18 ATEX 5003 X |
Certificate of suitability - according to UKCA | ITS21UKEX0464, ITS21UKEX0455X |
Parameter | Value |
---|
Explosion device group and category (according to ATEX directive 2014/34/EU) | II (2) G, II (2) D, I (M2) / I (M2), II (1/2) G, II (1G/2D) |
Galvanic Isolation
Parameter | Value |
---|
(Electrically) protective separation (according to IEC 60947-1) | All circuits with protective separation (double creepage paths and clearances), the information in the "Protective Separation" test report, No. A0258, must be observed (link see further information) |
Design of the electrical isolation - note | Protective separation in accordance with IEC 60947-1 for all circuits. Test report No. A0258 must be observed (link see further information). |
Control Circuit / Control
Parameter | Value |
---|
Product function soft starter control | Yes |
Type of voltage of the control supply voltage | DC |
Control supply voltage at DC rated value | 24 V |
Control supply voltage 1 at DC rated value | 24 V |
Operating range factor control supply voltage rated value at DC | |
• Initial value | 0.85 |
• Full-scale value | 1.2 |
Inrush current peak - at 24 V | 17 A |
Duration of inrush current peak - at 24 V | 1.1 ms |
Approvals Certificates
General Product Approval: CCC, UK CA, CE, EG-Konf., UL, EAC, RCM, EMV
For use in hazardous locations: ATEX, IECEx (multiple certifications listed)
Test Certificates: Special Test Certificate, Type Test Certificates/Test Report
Maritime application: Maritime application, other (e.g., RMRS, DNV, ABS, LRS)
Environment: Confirmation, EPD, Environmental Confirmations
Industrial Communication: PROFINET, Profibus
Diagram Descriptions
Device Dimensions and Layout: A front view shows the device with terminal blocks and status LEDs. A side view shows the overall dimensions: 111 mm height, 45 mm width, and 124 mm depth. Terminal labels visible include IN1, IN2, IN3, IN4, 24V, OUT1/2, OUT3, Port 1, Port 2, DEVICE, BUS, GEN. FAULT, Logic.
Wiring Diagram: A detailed wiring diagram illustrates the terminal connections. Power supply terminals are A1(+) and A2(-), with SPE (Screened Power Earth) and PE (Protective Earth). Communication ports are labeled -Port1:PN and -Port2:PN, connected via T1 and T2. Digital inputs are IN1 (terminal 9), IN2 (terminal 10), IN3 (terminal 4), and IN4 (terminal 5). A 24V terminal is present (terminal 8). Outputs are OUT1/2 (terminal 1) and OUT3 (terminal 7).