ActronAir GENESIS 15-17kW Package
Tailored Comfort, Built for Businesses
A Smarter Start to a Sustainable Future
Where innovation and purpose come together to elevate air conditioning for Australia's commercial spaces. Designed to meet today's needs and tomorrow's opportunities, GENESIS offers more than just a product - it's a commitment to delivering smarter, more efficient solutions.
The GENESIS package utilizes R32 refrigerant for improved environmental performance.
Advanced Technology. Commercial Confidence.
Packed with advanced features, ActronAir's rooftop package unit is engineered to deliver superior performance across a wide range of commercial applications. From enhanced energy efficiency and smart load matching to robust weather protection and flexible control options, every element is designed with practicality and performance in mind.
- Variable Speed EC Fans: Lower Energy Consumption
- Inverter Scroll Compressors: Enhanced Efficiency and Performance
- Wide Operating Range: (-10°C to 52°C) Designed for Australian conditions
Seamless Control for Smarter Spaces
NEO delivers precise comfort control and an intuitive interface, with smart dashboards built for commercial integration. Complementing NEO, the control range includes the Group Controller and LC7, with after-hours functionality to meet NCC compliance.
Control Features Overview:
Features | Group Controller | NEO | LC7 |
---|---|---|---|
Colour Options | Black | White or Black | White or Grey |
Touch Screen | ❌ | ✔️ | ✔️ |
Commercial Dashboards | ✔️ | ❌ | ❌ |
Multiple System Connectivity / Group Control | ✔️ | ❌ | ❌ |
Onboard Temperature Sensor | ❌ | ✔️ | ✔️ |
Optional Remote Sensor | ❌ | ✔️ | ✔️ |
Set Point Displayed | ✔️ | ✔️ | ✔️ |
Optional Temperature Set Point and Time Display | ❌ | ✔️ | ✔️ |
Auto Heat / Cool Change Over | ✔️ | ✔️ | ✔️ |
Self Diagnostic Fault Code Display | Fault Indicator Only | ✔️ | ✔️ |
24 Hour Timer | ✔️ | ✔️ | ✔️ |
7 Day Time Clock | ✔️ | ✔️ | ✔️ |
Set Back / Away Temperature | ❌ | ✔️ | ✔️ |
Adjustable Dead Band | ✔️ | ✔️ | ✔️ |
Adjustable Set Point in 0.5°C Increments | ✔️ | ✔️ | ✔️ |
Dual Control Capability - Optional (Using Mimic Logic) | ❌ | ✔️ | ❌ |
Return Air Filter Indicator | ✔️ | ✔️ | ✔️ |
After Hours Timer Function (NCC Compliant) | ✔️ | ✔️ | ✔️ |
Memory for Auto Restart after Power Failure | ❌ | ✔️ | ✔️ |
Damper Settings | ✔️ | ✔️ | ✔️ |
NFC Technology | ❌ | ✔️ | ❌ |
Set Temperature Lock | ✔️ | ✔️ | ✔️ |
Controller Lock | ✔️ | ✔️ | ✔️ |
Diagnostic Dashboard | ✔️ | ✔️ | ✔️ |
In Built Wi-Fi | ❌ | ❌ | ✔️ |
Over The Air Updates | ❌ | ❌ | ✔️ |
Mobile App Connectivity | ❌ | ❌ | ✔️ |
Specification Table
Technical Specifications | PRV15BT-T | PRV17BT-T |
---|---|---|
Nett (Rated) Capacity (kW) (AS/NZS3823.1.2) | Cooling (Min/Rated/Tru-Max): 4.49/14.80/16.50 | Cooling (Min/Rated/Tru-Max): 4.65/17.00/18.80 |
Input Power (kW) (AS/NZS3823.1.2) | Heating (Min/Rated/Tru-Max): 4.48/15.00/17.50 | Heating (Min/Rated/Tru-Max): 5.30/17.60/19.10 |
EER ¹ | Rated: 4.42, Tru-Max: 4.08 | Rated: 4.99, Tru-Max: 4.69 |
COP ² | Rated: 3.344, Tru-Max: 3.672 | Rated: 3.405, Tru-Max: 3.752 |
Power Supply - (V/Ph/Hz) | 400V/3Ph + N/50Hz | 400V/3Ph + N/50Hz |
Seasonal Performance - Commercial TCSPF - Cold / Avg. / Hot | 9.672/7.003/6.414 | 5.656/5.174/5.090 |
Seasonal Performance - Commercial HSPF - Cold / Avg. / Hot | 3.649/4.040/4.294 | 3.655/4.097/4.429 |
Rated Amps (AS/NZS3823.1.2) | 9.0 | 9.9 |
Full Load Amps (AS/NZS3823.1.2) | 13.8 | 15.2 |
Circuit Breaker Amps (Suggested) ³ | 16.0 | 16.0 |
IP Rating | IP44 | IP44 |
Fans (Type x Number per unit) | Outdoor: Variable Speed EC Axial Fan x 2 | Outdoor: Variable Speed EC Axial Fan x 2 |
Fans (Type x Number per unit) | Indoor: Variable Speed EC Plug Fan | Indoor: Variable Speed EC Plug Fan |
Compressor | Type / No. per Unit: Inverter Variable Speed Scroll / 1 | Type / No. per Unit: Inverter Variable Speed Scroll / 1 |
Compressor | Starting Method: Inbuilt Soft Starting | Starting Method: Inbuilt Soft Starting |
No. of refrigeration Circuits / No. Capacity Stages (Capacity range) | 1 / Variable Capacity | 1 / Variable Capacity |
Refrigerant | R32 | R32 |
Airflow Range Indoor (l/s) | Nominal: 770, Minimum: 620 | Nominal: 890, Minimum: 710 |
Unit Dimensions (mm) | Height: 1136, Width: 1523, Depth: 920 | Height: 1166, Width: 1523, Depth: 1060 |
Nominal Weight (kgs) ⁴ | 233 | 242 |
Foot Notes:
- EER Rated = Energy Efficiency Ratio (Rated Capacity Cooling / Rated Input Cooling). Measured and tested in accordance with AS/NZS3823.1.2.
- COP Rated = Coefficient of Performance (Rated Capacity Heating / Rated Input Heating). Measured and tested in accordance with AS/NZS3823.1.2.
- Suggested minimum cable size. This should be used as a guide only. Refer to AS/NZS 3000 "Australian/New Zealand Wiring Rules" for more details.
- Refer to Catalogue Unit Weight Distribution Guide section for details of weight points.
- Sound Pressure Level at 3m distance is determined as the measured sound pressure at 3m perpendicular to the coil side of the condenser.
- Measured based on ISO 3743-1, Determination of Sound Power Levels and Sound Energy Levels of Noise Sources Using Sound Pressure.
- When Demand Response capability is chosen, the air conditioner will fully comply.
Rated Conditions:
Cooling: 35°C DB Outdoor / Air Entering Indoor 27°C DB, 19°C WB
Heating: 7°C DB, 6°C WB Outdoor / Air Entering Indoor 20°C DB
Important Notes:
- The Local Electricity Supply Authority may require limits on starting current, running current and voltage drop; please check prior to purchase.
- When the outdoor temperature exceeds the rated conditions, the cooling/heating capacities may decrease the rated nett values.
- Specifications subject to change without notice.
Warranty: For full terms and conditions of ActronAir warranty, please refer to warranty terms document - www.actronair.com.au
Installation Information
Options | Installation Information |
---|---|
Additional Outdoor Coil Coat Protection (K) | Refrigerant Factory Charge (grams): 2450 (PRV15BT-T), 2730 (PRV17BT-T) |
Additional Indoor Coil Coat Protection (L) | Condensate Drain Connection Size: 25mm ID BSP |
Vertical Discharge Fan Coil | Air Duct Connection: Supply Duct H x W (mm): 348 x 1100, Return Duct H x W (mm): 200 x 740 |
Bluetooth Commissioning Tool (BCT) | BMS Compatibility: Yes |
Compressor Sound Jacket | CO2 Sensor: Yes |
AIR CONDITIONING DESIGNED FOR AUSTRALIA
Find out more at docs.actronair.com.au