Connecting the OPC-2389
Step 1: Turn OFF all devices that are connected to the VE-PG3 or VE-PG4, and then connect the OPC-2389 as shown below.
Diagram Description: The VE-PG4 rear view illustrates the connection points. The OPC-2389 cable connects to the [EXT1] port. It is crucial to ensure the connector is inserted top side up.
Note: This example demonstrates connecting a serial communication device to the [EXT1] port.
Important Cautions:
- Verify that both the repeater and the VE-PG3 or VE-PG4 are turned OFF when connecting or disconnecting the cable.
- Always hold the connector body when connecting or disconnecting.
- If other cables are connected, needle-nose pliers can be used to carefully insert or remove connectors.
- Never pull the connector by holding the cable, as this will damage the cable.
- Never bend or pinch the cable.
- Never place a heavy object on the cable.
- Never touch the cable with wet hands.
- Always connect the cable correctly. An incorrect connection could damage the VE-PG3 or VE-PG4 and/or the connected device.
- Never add pulling tension to the cable.
- Only use the OPC-2389 with VE-PG3 and VE-PG4 devices.
- Compatibility with all serial communication devices is not guaranteed.
Replacing the Connector
If the cable becomes damaged, replace the connector(s). Make wire connections as described below. Spare connectors (Manufacturer: DDK, Name: 232D-04S1B-DA5-FA) are supplied with the VE-PG3 or VE-PG4.
The connector consists of two parts: a black base and a clear insert. Do not lock the connector parts before inserting all wires.
Step 1: Insert the wires into the holes according to the assigned pin numbers.
Diagram Description: The connector is shown with wires inserted. The wires for each hole are assigned by color. Refer to the illustration below for wire color to pin number mapping.
Step 2: Press the clear insert down until it locks in place.
Note: Once the insert is locked, it cannot be released.
Recommendation:
If the connector is reconnected approximately 30 times, it is recommended to cut the wires near the connector and replace it with a new one. Ensure the cable is removed from the VE-PG3 or VE-PG4 before cutting the wires. Do not cut the wires too short, as this will make reconnection difficult.
Diagram Description: The OPC-2389 connection and wire assignment is detailed. The connector top is shown in an expanded view, with labels B and C indicating different connector sections. The wire colors are mapped to pin numbers as follows:
Connector B Wire Assignment:
- Pin 1: Brown
- Pin 2: Red
- Pin 3: Orange
- Pin 4: Yellow
Connector C Wire Assignment:
- Pin 1: Gray
- Pin 2: Purple
- Pin 3: Blue
- Pin 4: Green