ICOM IC-SAT100M NETWORK SETTING

When the transceiver is connected to network devices, change the static IP address. Before using the transceiver, set a static IP address to the antenna unit and the main unit with EX-4241 Utility for IC-SAT100M. This manual shows system requirements and how to use the software.

Table of contents

System requirements

The following hardware and software are required:

Operating System (OS)

The instructions are based on using Microsoft Windows 10.

Cables (Purchase separately)

Operation note

Icom, Icom Inc. and the Icom logo are registered trademarks of Icom Incorporated (Japan) in Japan, the United States, the United Kingdom, Germany, France, Spain, Russia, Australia, New Zealand, and/or other countries. Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and/or other countries. All other products or brands are registered trademarks or trademarks of their respective holders.

Installing the EX-4241

  1. Sign in to the PC as the administrator. Confirm that no other applications are running.
  2. Download and unzip the file.
  3. Double-click "setup.exe." If the "User Account Control" dialog is displayed, click [Yes]. "Choose Setup Language" is displayed.
  4. On the "Welcome to the InstallShield Wizard for EX-4241" screen, click [Next >>].
  5. "User Information" is displayed. Enter your name (option), your company name (option), and the product ID number as described below. Click [Next >>].
    • Product ID number: 424111-(6 digit serial number)
    • If you downloaded the software, enter the ID provided by your distributor.
  6. "Software License Agreement" is displayed. Read carefully, and if you agree to the terms and conditions, click [Yes].
  7. On the "Choose Destination Location" screen, click [Next >>]. If desired, click [Browse...] and select another destination folder before clicking [Next >>].
  8. After the installation has completed, click [Finish].
  9. A "EX-4241" folder is created in the Windows Start menu, and a shortcut icon is added onto the desktop.

TIP: You can uninstall the EX-4241 using the "Apps & features" in the "Apps” menu. To get started, click on Start > Settings > Apps > Apps & features.

Before connecting the OPC-2357 to the PC

To use the OPC-2357 PROGRAMMING CABLE, you must first install a USB driver. The driver and installation guide are supplied with the programming cable. Read the guide carefully before installing the driver.

Connecting with PC

  1. Be sure the transceiver is OFF, and Windows has completed its startup.
  2. Connect the cable, as shown below.
  3. Turn ON the transceiver.

Default

IP address:192.168.0.1 (Main Unit)
192.168.0.2 (Antenna Unit)
Subnet Mask:255.255.255.0
Default Gateway:192.168.0.254

Diagram illustrating the connection between the IC-SAT100M Main Unit (labeled with IP address 192.168.0.1), Antenna Unit (labeled with IP address 192.168.0.2), a PC, and a Microphone. The OPC-2357 programming cable connects the Main Unit to the PC via a USB connector. The diagram also shows a "Turn OFF" indicator on the Antenna Unit and a "To a USB connector" label for the PC.

Editing Network Setting

NOTE:

  1. Click "EX-4241" in the Start menu, and then click "EX-4241" to start the software. For Microsoft® Windows® 8.1: Navigate from to EX-4241. You can also start the software by simply double-clicking the EX-4241 shortcut icon on the desktop.
  2. Click "Port Select" from the <COM Port> menu, and then select the COM port number that the programming cable is connected to.
  3. Click, or select "Read <- TR" in the <Program> menu to read the data from the setting data.
  4. Click "Network Settings" and set the IP address, Subnet Mask, and Default Gateway for the IC-SAT100M Main Unit and Antenna Unit.
  5. When registering two or more IC-SAT100M to VE-PG4, set the Control Port and Voice Port.
  6. Click, or select "Write -> TR" in the <Program> menu to write the setting data into the transceiver.

This is a default setting.

About basic operation

To read the data from the transceiver

Select "Read <- TR" in the <Program> menu.

To write the setting data into the transceiver

Select "Write -> TR" in the <Program> menu.

To reset to the transceiver default settings

Select "All Reset" in the <Program> menu. Connect the Main Unit and the Antenna Unit, as shown in the illustration on page 3. If you select "All Reset," the settings on the IC-SAT100M Menu screen are also initialized.

To save the settings file to a folder on your PC

Select "Save" or "Save As..." in the <File> menu. If you have a data file to write to the transceiver, select "Open..." in the <File> menu, and then select the file.

COM Port Searching

To Confirm the COM port number

  1. Click the folder icon [File Explorer Icon] on the taskbar.
  2. Right-click "This PC," and then click "Properties."
  3. Click [Device Manager]. The "Device Manager" screen is displayed.
  4. Double-click "Ports (COM & LPT)." The COM port for the Icom USB-to-Serial Comm Port will be displayed.

Connecting with the network devices

After changing the IP address of the IC-SAT100M, connect the black LAN cable (for network) and the network devices such as a HUB.

Black: for network

Gray: for the Antenna Unit

Diagram showing the IC-SAT100M connected via a black LAN cable (labeled 'for network') to a HUB. The HUB is then connected to the network. A separate gray LAN cable connects the IC-SAT100M to the Antenna Unit.

Connecting the VE-PG4

The following is an example of connecting the RoIP Gateway and Satellite PTTs (IC-SAT100M), that enables you to make a call between an IP transceiver and a client Satellite PTT in the set Talkgroup on the RoIP Gateway.

Diagram illustrating a network setup with a VE-PG4 connected to a HUB, which is linked to an IP network. Two IC-SAT100M units are shown as 'Transceiver A' and 'Transceiver B', connected to the network and acting as Satellite PTT clients and IP Transceivers. Each unit has specific IP addresses, voice/control port numbers, and group IDs.

Information

If you want to use the Emergency Call function:

Connect another IC-SAT100M to the [RoIP Gateway] port for the emergency calls.

Setting Example: Talkgroup 1 (for usual calls): Uses the IC-SAT100M (IP address: 192.168.0.50). Talkgroup 15 (for emergency calls): Uses the IC-SAT100M (IP address: 192.168.0.70).

Before connecting the IC-SAT100M to your network:

  • On the IC-SAT100M, select "TCP" in the PC Command setting. ([OK] > Function > PC Command)
  • Check your network configuration and settings, and then ask your dealer to enter the fixed IP addresses, subnet mask, and default gateway addresses to the IC-SAT100M main units and the antenna units.
  • Be sure to enter the IP addresses of your IC-SAT100Ms (Main units) to the VE-PG4.

IC-SAT100M default settings

IC-SAT100M (Main unit)IP address: 192.168.0.1
Subnet mask: 255.255.255.0
Default gateway: 192.168.0.254
Antenna unitIP address: 192.168.0.2
Subnet mask: 255.255.255.0
Default gateway: 192.168.0.254
VE-PG4Control Port Number: 53000
Voice Port Number: 51000

When connecting two or more IC-SAT100Ms to the VE-PG4, do not conflict the Voice Port Number settings.

Connecting to the IP Network

Connect to the network, and then set up the connection and destination settings on the RoIP Gateway setting screen. This instruction describes as the IP transceiver setup has been completed.

  1. Open the RoIP Gateway screen. (Connection Port Settings > RoIP Gateway)
  2. In [RoIP Gateway Mode], set Mode to "Transceiver" in the RoIP Gateway (1 ~ 8) that you want to connect the Transceiver A (IC-SAT100M) to. (Example: RoIP Gateway 1)
  3. In [RoIP Gateway], select a RoIP Gateway port (1 ~ 8) that you set in the step 2, and then confirm that the [Transceiver Model] is set to "IC-SAT100M." (Example: RoIP Gateway 1)
  4. In [Transceiver Connection], enter the Transceiver A (IC-SAT100M) settings to Destination Address, Destination Port Number, and Control Port Number. Then click [Apply].
  5. In [Transceiver Connection], click [Connect]. The Connection Status changes to "Connecting."
  6. Do the same way in the steps 2 to 5, enter the Transceiver B (IC-SAT100M) settings.

Screenshots of the RoIP Gateway and Transceiver Connection settings screens are described here, showing fields for Mode, Transceiver Model, Destination Address, Destination Port Number, Control Port Number, and Connection Status.

Entering the Destination Settings

This instruction describes as the IP transceiver setup has already been completed.

Diagram showing a VE-PG4 connected to a HUB, which is linked to an IP network. Two IC-SAT100M units are shown as 'Transceiver A' and 'Transceiver B', connected to the network and acting as IP Transceivers. Each unit has specific IP addresses, voice/control port numbers, and group IDs.

  1. Open the Destination Settings screen. (Destination Settings > Destination Settings)
  2. In [Destination Settings], enter the settings for the Transceiver A (Name, Call Type, Destination ID, and IP Transceiver Controller), and then click [Apply].
  3. Do the same way in step 2, enter the Group 00002 settings.

Screenshots of the Destination Settings screen are described here, showing fields for Name, Call Type, Destination ID, IP Transceiver Controller, and Communication Type.

PDF preview unavailable. Download the PDF instead.

SAT100M Network Settings Adobe PDF Library 15.0

Related Documents

Preview Icom Professional Radio Solutions: IP, LTE, Satellite, WLAN, Digital & Analog Radios
Explore Icom's comprehensive range of professional two-way radio communication systems, including IP, LTE, Satellite PTT, WLAN, IDAS digital, and analog radios, designed for reliable business communication.
Preview Icom VE-PG4 RoIP Gateway Operating Guide
This operating guide provides comprehensive instructions for the Icom VE-PG4 RoIP Gateway, detailing its features, network configuration, transceiver management, and port settings for seamless radio-to-IP communication.
Preview Icom IC-F5120D & IC-F6120D Series VHF/UHF Mobile Transceiver Instruction Manual
Explore the Icom IC-F5120D and IC-F6120D series VHF/UHF mobile transceivers with this official instruction manual. Learn about panel features, basic operation, connections, maintenance, and safety protocols for professional radio communication.
Preview Icom IC-7800 Instruction Manual: Your Guide to Advanced Amateur Radio
Discover the features and operation of the Icom IC-7800 amateur HF/50 MHz transceiver with this comprehensive instruction manual. Learn about installation, panel descriptions, basic and advanced operations, and maintenance from Icom.
Preview ICOM OPC-2389 Connection Cable Instructions
Detailed instructions for connecting the ICOM OPC-2389 serial communication cable to VE-PG3 and VE-PG4 devices, including connector replacement guidance and wire assignments.
Preview Icom IC-7300 HF/50 MHz Transceiver Basic Manual
This manual provides basic operating instructions for the Icom IC-7300 HF/50 MHz Transceiver, covering features like the RF Direct Sampling System, Real-Time Spectrum Scope, and IP+ function. It details panel descriptions, installation, basic operation, receiving and transmitting, scope operation, SD card usage, antenna tuner, set mode, maintenance, specifications, and options.
Preview Icom IC-7410 HF/50 MHz Transceiver Instruction Manual
Comprehensive instruction manual for the Icom IC-7410 HF/50 MHz transceiver, covering features, installation, operation, maintenance, and specifications.
Preview Icom VE-PG3/4 to Portable Radio Cable Connection Guide
Detailed guide and diagram for creating a connection cable between Icom VE-PG3/VE-PG4 units and Icom portable radios, including pin assignments and connector part numbers.