Description

The 2300 Series is designed for use with sectional/panel overhead doors that use metal roller tracks. The contact fits roller tracks up to 3 inches wide.

Selecting a Location

Use the following guidelines to select a location for the contact:

  • Mount the switch high enough so the cable is off the floor. If other track-mounted devices interfere, mount the switch under them.
  • Locate the magnet away from handles and latches to prevent it from being used as a foothold or a handle to close the door.

Installing the Contact

  1. Run the security system wiring to the switch location.
  2. Place the switch over the door track. See Figure 1.
  3. Slide the beveled edge of the L-bracket into the slot of the switch until it snaps firmly in place. Tighten the screw on the switch down firmly.
  4. Align the magnet with the switch and attach it to the door with the two screws provided as follows:
    • The magnet must be 1/4 to 1/2 inch away from the switch. See Figure 3.
    • The magnet can be attached at two different elevations from the door. See Figure 3.
  5. Connect the switch wires to the security system wiring and verify the switch works properly.

Diagrams:

Figure 1 - Mounting the Switch: Illustrates the switch being mounted onto a metal roller track of an overhead door. It shows an L-bracket attached to the switch, which is then positioned over the track. A screw secures the bracket to the switch.

Figure 2 - Attaching Magnet to Door: Depicts the magnet being affixed to the door panel, positioned in proximity to the switch.

Figure 3 - Magnet Mounting Options: Shows two different vertical placements for the magnet on the door relative to the switch. It specifies a gap of 1/4 to 1/2 inch between the magnet and the switch when the door is closed.

Specifications

  • Gap (make) distance ±20%: 3" (7.5 cm) max.
  • Break distance: approx. 1.1 to 1.5 times make distance
  • Lead type: 2' (0.61 m) stainless steel armored cable
  • Magnet/switch housing: extruded aluminum
  • Operating temperature: -40° to 150°F (-40° to 65°C)

Switch Dimensions:

  • Length: 3.25" (8.26 cm)
  • Depth: 3.75" (9.53 cm)
  • Width: 2.73" (6.93 cm)

Magnet Dimensions:

  • Length: 3.51" (8.92 cm)
  • Depth: 1.70" (4.32 cm)
  • Width: 3.10" (7.87 cm)
  • Listing: UL 634 pending

Electrical Specifications/Ordering

Model NumberElectrical ConfigurationLoop TypeVoltageCurrentPower
2325ANOClosed100 VAC/DC max.0.5A max.7.5 W max.
2327ASPDTOpen or Closed30 VAC/DC max.0.25A max.3 W max.

Contact Information

Corporate Headquarters:
12345 SW Leveton Dr., Tualatin, OR 97062
Tel: 503.692.4052 | Fax: 503.691.7566
http://www.sentrol.com

U.S. & Canada: 800.547.2556

Technical Service: 800.648.7424

FaxBack: 800.483.2495

Note: Sentrol reserves the right to change specifications without notice. ©1999 Sentrol. Document Revision: 1031684 Rev A, 11/99.

PDF preview unavailable. Download the PDF instead.

1031684 A 2300 Door Contact Installs Acrobat Distiller 3.01 for Windows PageMaker 6.5

Related Documents

Preview Sentrol R1078 Magnetic Contacts: Installation Guide and Specifications
Installation guide and technical specifications for the Sentrol R1078 1" Diameter Steel Door Magnetic Contacts, covering installation steps, UL/ULC ratings, and gap distance details.
Preview Sentrol 1078CT Series Steel Door Magnetic Contacts: Specifications & Installation
Detailed specifications and installation instructions for Sentrol 1078CT Series 3/4" diameter steel door magnetic contacts, including gap distances, electrical configurations, and UL/ULC ratings.
Preview Sentrol 1082 Series Magnetic Contacts: Installation and Specifications
Comprehensive guide to Sentrol 1082 Series screw mount magnetic contacts, detailing installation, UL/ULC specifications, gap distances, and electrical configurations for models 1082, 1083W, 1084D, and 1084W.
Preview Sentrol 1078CT Series Magnetic Contacts: Installation and Specifications
Detailed installation instructions, specifications, and gap distances for Sentrol 1078CT, 1078CTW, and R1078CT series magnetic contacts for steel doors.
Preview Sentrol RCR Range-Controlled Radar Detector Installation and User Manual
Comprehensive installation and user guide for the Sentrol RCR detector, featuring range-controlled radar (RCR) and passive infrared (PIR) technology for enhanced false alarm immunity. Includes setup, maintenance, specifications, and FCC compliance information.
Preview Sentrol Advisor X DV1201/DV1221 Structural Vibration Detection System Installation Guide
Installation instructions and technical data for the Sentrol Advisor X Structural Vibration Detection System, models DV1201 and DV1221, designed for detecting break-in attempts on vaults, safes, night deposit units, and other secure physical areas.
Preview Sentrol Application Notes: Security Sensor Installation Guide
Comprehensive application notes and installation guide for Sentrol's range of glassbreak sensors, motion detectors, and magnetic contacts, covering residential and commercial security solutions.
Preview Sentrol Advisor X DV1200 Series Structural Vibration Detection System Installation Guide
Comprehensive installation instructions for the Sentrol Advisor X DV1200 Series Structural Vibration Detection System (Models DV1201, DV1221). Learn about planning, mounting, wiring, and testing for enhanced security in vaults, safes, ATMs, and more.