Honeywell FocusPRO 5000 Series Non-Programmable Digital Thermostat Installation Instructions

Wallplate Installation

Remove the wallplate from the thermostat, then follow directions below for mounting.

  1. Remove battery holder.
  2. Pull here to remove wallplate from new thermostat.
  3. Pull wires through wire hole.
  4. Position wallplate on wall, level and mark hole positions with pencil.
  5. Drill holes at marked positions, then tap in supplied wall anchors. For drywall, drill 3/16" holes. For plaster, drill 7/32" holes.
  6. Place wallplate over anchors, insert and tighten mounting screws.

Power Options

Connect C for primary AC power (optional if batteries are installed).

Insert batteries for primary or backup power.

Wiring Terminal Designations

Conventional Terminals:

Heat Pump Terminals:

Wiring Conventional Systems

Heat-Only System

Wiring: W, C, R, Rc

Heat-Only System with Fan

Wiring: G, C, R, Rc

Cool-Only System

Wiring: G, C, Y, R, Rc

1H/1C System (1 transformer)

Wiring: G, W, C, Y, R, Rc

1H/1C System (2 transformers)

Wiring: G, W, C, Y, R, Rc

2H/2C System (1 transformer)

Wiring: Y2, W2, G, W, C, Y, R, Rc

2H/2C System (2 transformers)

Wiring: Y2, W2, G, W, C, Y, R, Rc

Notes:

Wiring Heat Pump Systems

1H/1C Heat Pump System

Wiring: G, O/B, C, Y, R, Rc

2H/1C Heat Pump System (TH5220D only)

Wiring: Aux/E, L, G, O/B, C, Y, R, Rc

2H/1C Heat Pump System (TH5320U only)

Wiring: Aux/E, L, G, O/B, C, Y, R, Rc

2H/2C Heat Pump System (TH5320U only)

Wiring: Y2, L, G, O/B, C, Y, R, Rc

3H/2C Heat Pump System (TH5320U only)

Wiring: Aux/E, Y2, L, G, O/B, C, Y, R, Rc

Notes:

Thermostat Mounting

  1. Push excess wire back into the wall opening.
  2. Plug wall opening with nonflammable insulation.
  3. Align the 4 tabs on the wallplate with corresponding slots on the back of the thermostat.
  4. Push gently until the thermostat snaps in place.

Installer Setup

Follow the procedure below to configure the thermostat to match the installed heating/cooling system, and customize feature operation as desired.

  1. To begin, press and hold the Δ and FAN buttons until the display changes.
  2. Press Δ or to change settings.
  3. Press NEXT to advance to next function.
  4. Press DONE to exit and save settings.

Setup Function and Settings:

Function # Settings & Options (factory default in bold)
1 System type 0 1 heat/1 cool conventional
1 1 heat/1 cool heat pump (no aux. heat)
2 Heat only - 2-wire systems, 3-wire zone valves (Series 20), and normally open zone valves
3 Heat only with fan
4 Cool only
5 2 heat/1 cool heat pump (with aux. heat)
6 2 heat/2 cool conventional
7 2 heat/1 cool conventional
8 1 heat/2 cool conventional
9 2 heat/2 cool heat pump (no aux. heat) - TH5320U only
10 3 heat/2 cool heat pump (with aux. heat) - TH5320U only
2 Changeover valve (O/B terminal) 0 Changeover valve (O/B terminal energized in cooling)
1 Changeover valve (O/B terminal energized in heating)
3 Fan control (heating) 0 Gas or oil furnace - equipment controls fan in heating
1 Electric furnace - thermostat controls fan in heating
5 Stage 1 heat cycle rate (CPH) 5 For gas or oil furnaces of less than 90% efficiency
1 For steam or gravity systems
3 For hot water systems & furnaces of over 90% efficiency
9 For electric furnaces
6 Stage 2 heat cycle rate/Auxiliary heat cycle rate (CPH) 5 For gas or oil furnaces of less than 90% efficiency
1 For steam or gravity systems
3 For hot water systems & furnaces of over 90% efficiency
9 For electric furnaces
7 Auxiliary heat cycle rate (CPH) (Only TH5320U for 3H/2C Heat Pumps) 5 For gas or oil furnaces of less than 90% efficiency
1 For steam or gravity systems
3 For hot water systems & furnaces of over 90% efficiency
9 For electric furnaces
9 Stage 1 compressor cycle rate (CPH) 3 Recommended for most compressors [Other cycle rate options: 1, 2, 4, 5 or 6 CPH]
10 Stage 2 compressor cycle rate (CPH) 3 Recommended for most compressors [Other cycle rate options: 1, 2, 4, 5 or 6 CPH]
12 Manual/Auto changeover 0 Manual changeover (Heat/Cool/Off)
1 Auto changeover (Heat/Cool/Auto/Off)
2 Auto changeover only (Auto)
14 Temperature display 0 Fahrenheit
1 Celsius
15 Compressor protection 5 Five-minute compressor off time [Other options: 0, 1, 2, 3 or 4-minute off time]
26 Auxiliary heat control 0 Comfort
1 Economy
27 Heat temperature range stops 90 Max. heat temperature setting is 90°F (32°C) [Other options: 40°F to 89°F (4.5°C to 31.5°C)]
28 Cool temperature range stops 50 Min. cool temperature setting is 50°F (10°C) [Other options: 51°F to 99°F (10.5°C to 37°C)]

Special Function

Auxiliary heat control (Setup Function 26):

Installer System Test

Follow the procedure below to configure the thermostat to match the installed heating/cooling system, and customize feature operation as desired.

  1. To begin, press and hold the Δ and buttons until the display changes.
  2. Press Δ / ∇ to turn system on/off.
  3. Press NEXT to advance to next test.
  4. Press DONE to terminate system test.

System Test Status:

Test # System Status
10 Heating system 0 Heat and fan turn off.
1 Stage 1 heat turns on. Fan turns on if Setup Function 1 is set to 1, 5, 9 or 10 OR Setup Function 3 is set to 1
2 Stage 2 heat turns on
3 Stage 3 heat turns on - TH5320U only
20 Emergency heating 0 Heat and fan turn off system
1 Heat and fan turn on
30 Cooling system 0 Compressor and fan turn off
1 Compressor and fan turn on
2 Stage 2 compressor turns on
40 Fan system 0 Fan turns off
1 Fan turns on

Specifications

Temperature Ranges

Operating Ambient Temperature

32° to 120°F (0° to 48.9°C)

Shipping Temperature

-20° to 120°F (-28.9° to 48.9°C)

Operating Relative Humidity

5% to 90% (non-condensing)

Physical Dimensions

Electrical Ratings

Terminal Voltage (50/60Hz) Running Current
W Heating 20-30 Vac 0.02-1.0 A
(Powerpile) 750 mV DC 100 mA DC
W2 (Aux/E) Heating 20-30 Vac 0.02-1.0 A
Y Cooling 20-30 Vac 0.02-1.0 A
Y2 Cooling 20-30 Vac 0.02-1.0 A
G Fan 20-30 Vac 0.02-0.5 A
O/B Changeover 20-30 Vac 0.02-0.5 A
L Output 20-30 Vac 0.02-0.5 A

Customer Assistance

For assistance with this product, please visit customer.honeywell.com.

Or call Honeywell Customer Care tollfree at 1-800-468-1502.

Pull at bottom to remove thermostat from wallplate.

Turn thermostat over to find model number and date code.

CAUTION: EQUIPMENT DAMAGE HAZARD

Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly.

CAUTION: ELECTRICAL HAZARD

Can cause electrical shock or equipment damage. Disconnect power before beginning installation.

CAUTION: MERCURY NOTICE

If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste management authority for instructions regarding recycling and proper disposal.

Automation and Control Solutions

Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN 55422

Honeywell Ltd
705 Montrichard Avenue
Saint-Jean-sur-Richelieu, Québec
J2X 5K8

customer.honeywell.com

PDF preview unavailable. Download the PDF instead.

7cf0bc87-7805-4088-b832-96cafa469f55 Adobe PDF Library 9.9

Related Documents

Preview Honeywell FocusPRO 5000 Series Non-Programmable Digital Thermostat Installation Instructions
This document provides comprehensive installation, setup, and operation instructions for the Honeywell FocusPRO 5000 Series Non-Programmable Digital Thermostat. It covers wallplate installation, power options, detailed wiring diagrams for conventional and heat pump systems, thermostat mounting, installer setup procedures, system testing, specifications, and customer assistance.
Preview Honeywell FocusPRO TH5000 Series Thermostat Installation Guide
Comprehensive installation guide for the Honeywell FocusPRO TH5000 Series non-programmable digital thermostats, covering models TH5110D, TH5220D, and TH5320U. Includes wiring diagrams, setup procedures, and specifications.
Preview Honeywell FocusPRO TH5000 Series Non-Programmable Digital Thermostat Manual
User manual for the Honeywell FocusPRO TH5000 Series non-programmable digital thermostat, covering features, operation, troubleshooting, and warranty.
Preview Honeywell FocusPRO 5000 Series Digital Thermostat User Guide
User guide for the Honeywell FocusPRO 5000 Series digital thermostat, covering installation, operation, troubleshooting, and warranty information.
Preview Honeywell FocusPRO TH5220D Non-Programmable Digital Thermostat Installation Guide
Installation guide for the Honeywell FocusPRO TH5220D non-programmable digital thermostat, covering product application, system types, power options, wiring, setup, testing, and troubleshooting.
Preview FocusPRO TH5220D Non-programmable Digital Thermostat User Guide
Learn how to operate and maintain your Honeywell FocusPRO TH5220D non-programmable digital thermostat. This guide covers features, setup, controls, display functions, system settings, and troubleshooting.
Preview Honeywell FocusPRO TH5220D Non-Programmable Digital Thermostat Installation Guide
This guide provides detailed instructions for installing and configuring the Honeywell FocusPRO TH5220D Non-Programmable Digital Thermostat. It covers wiring, system setup, and troubleshooting for various heating and cooling systems.
Preview Honeywell TH5110D Non-Programmable Thermostat Operating Instructions
Comprehensive operating instructions for the Honeywell TH5110D Non-Programmable Thermostat, covering features, setup, operation, battery replacement, troubleshooting, and warranty information.