Rinnai RXP199i, RXP160i Condensing Tankless Water Heater
Product Overview
SUPER-HIGH-EFFICIENCY (CONDENSING) TANKLESS WATER HEATER
Installation Type: Internal (Indoor) Residential Applications, External (Outdoor) Residential Applications with Outdoor Vent Cap
Model Numbers: RXP199i (REU-NBP3237FF-US), RXP160i (REU-NBP2530FF-US)
Approved Gas Types: Natural and Propane
Efficiency: UEF: 0.98 (RXP199i), 0.97 (RXP160i)
High Altitude Approved: Up to 10,200 ft (3,109 m)
Water Flow Control: Water Flow Sensor, Electronic Water Control and Bypass Control
Controller: Standard: Integrated Controller; Optional: MC-195T-US, MC-601-BK/W
Certifications: AHRI, ANSI Z21.10.3, CSA 4.3, and ENERGY STAR®
Flexible Venting Options
- ✔️ Concentric or Schedule 40 PVC/CPVC
- ✔️ Direct Vent (Concentric and Twin Pipe)
- ✔️ Non-Direct Vent (Room Air)
- ✔️ Common Vent (Direct Vent and Room Air)
Maximum Equivalent Vent Lengths:
Twin Pipe (PVC/CPVC and PP):
- Vent Sizes: 2 in. (51 mm) | 3 in. (76 mm)
- Vent Lengths: 75 ft (23 m) | 150 ft (46 m)
Concentric:
- Vent Sizes: 2 in. X 4 in. | 3 in. X 5 in.
- Vent Lengths: 75 ft (23 m) | 150 ft (46 m)
Ease of Installation and Serviceability
- ✔️ Smart-Sense™: Adaptive gas valve technology - No gas conversion kit required.
- ✔️ Versa-Vent™: Outdoor vent cap adapts to any SENSEITM RX Series model for outdoor installation.
- ✔️ Smart Connect™: Allows connection of phone or tablet to SENSEITM RX Series via Bluetooth® using Rinnai Central™ app.
- ✔️ Quick-Flush™: Provides an efficient flushing procedure for periodic preventive maintenance.
Warranty
- ✔️ Heat Exchanger: 15 years or 12,000 operation hours, whichever occurs first
- ✔️ All Other Parts and Components: 5 years
- ✔️ Reasonable Labor: 5 years* (*Requires product to be registered within 90 days of installation or labor warranty defaults to 1 year)
Safety Devices
- ✔️ Flame Failure - Flame Rod, Boiling Protection, Combustion Fan RPM Check, Over Current - Glass Fuse, Remaining Flame (OHS) and Automatic Frost Protection
Included with Purchase
- ✔️ Tankless Water Heater
- ✔️ Wall Mounting Bracket
- ✔️ Vent Screens (x2)
- ✔️ Screws (x2)
- ✔️ Self-Tapping Screws (x4)
- ✔️ Thermal Bypass Valve
Optional Accessories
Description | Part Number | Description | Part Number | Description | Part Number |
---|---|---|---|---|---|
Isolation Valves and PRV | MIVK-T-LW | Pipe Cover* | PCD11-SHS | Controllers | MC-601-BK/W, MC-195T-US |
Outdoor Vent Cap* | RXOVC | Recess Box for SENSEITM RX Series* | RGBCTWHRX | Condensate Neutralizer | 804000074 |
Dedicated Return with Isolation Valves and PRV* | 107000639 | Bottom Plate for Pipe Cover* | 109001364 | Scale Cutter | 103000038 |
Retrofit Door for RX in RGB-CTWH-4* | 104000335 | Wireless Module* | RWM200 | Scale Cutter Refill | 103000039 |
Retrofit Door for RX in RGB-CTWH-3, 2, 1* | 104000336 | Recirculation Push Button* | RPB200 | OPU Switch | REU-OPU3 |
Gas Conversion Kit (Labels Only)* | 104000330 | EZConnect Cable* | REU-EZC-3 | Leak Detection Kit* | RXLeakKit |
*New for SENSEITM RX/CX Series Water Heaters
SENSEITM RXP Technical Specifications
SPECIFICATION | RXP199i | RXP160i |
---|---|---|
Dimensions - w, h, d | 18.5 in. x 25.8 in. x 11.4 in. (470 mm x 654 mm x 290 mm) | 18.5 in. x 25.8 in. x 11.4 in. (470 mm x 654 mm x 290 mm) |
Minimum Gas Consumption Btu/h | 15,000 | 15,000 |
Maximum Gas Consumption Btu/h | 199,000 | 160,000 |
Flow Rate¹ (Min - Max) | 0.13 - 11.0 GPM (0.5 - 42 L/min) | 0.13 - 9.0 GPM (0.5 - 34 L/min) |
Weight | 58 lb (26 kg) | 57 lb (26 kg) |
Sound Level | 49 dB | 48 dB |
Electrical - Normal | 98 W | 73 W |
Electrical - Normal with Pump Operation | 170 W | 149 W |
Electrical - Standby | 1.3 W | 1.3 W |
Electrical - Freeze Protection | 174 W | 174 W |
Max Current | 4 Amps | 4 Amps |
Fuse | 10 Amps | 10 Amps |
Temperature | Minimum: 98° F (37° C) Default (Crossover Mode: 120°F (49°C)) Maximum: 120° F (49° C) Default 140° F (60° C) With Parameter Adjustment | Minimum: 98° F (37° C) Default (Crossover Mode: 120°F (49°C)) Maximum: 120° F (49° C) Default 140° F (60° C) With Parameter Adjustment |
By-Pass Flow Control | Electronic | Electronic |
Gas Supply Pressure² | Natural: 3.5 in. w.c. - 10.5 in. w.c. Propane: 8.0 in. w.c. - 13.5 in. w.c. | Natural: 3.5 in. w.c. - 10.5 in. w.c. Propane: 8.0 in. w.c. - 13.5 in. w.c. |
Ignition System | Direct Electronic Ignition | Direct Electronic Ignition |
Electronic Connections | Appliance: AC 120 Volts, 60Hz. Temperature Controller: DC 12 Volts (Digital) | Appliance: AC 120 Volts, 60Hz. Temperature Controller: DC 12 Volts (Digital) |
Water Supply Pressure | Minimum: 15 PSI (Recommended 50 PSI for max performance) Maximum: 150 PSI | Minimum: 15 PSI (Recommended 50 PSI for max performance) Maximum: 150 PSI |
Service Connections | Gas Supply: 3/4 in. (19 mm) NPT Cold Water Inlet: 3/4 in. (19 mm) NPT Hot Water Outlet: 3/4 in. (19 mm) NPT Condensate Drain: 1/2 in. (13 mm) NPT | Gas Supply: 3/4 in. (19 mm) NPT Cold Water Inlet: 3/4 in. (19 mm) NPT Hot Water Outlet: 3/4 in. (19 mm) NPT Condensate Drain: 1/2 in. (13 mm) NPT |
Clearances | Top: 2 in. (51 mm)* Bottom/Ground: 12 in. (305 mm) Front: 0 in.** Back: 0 in. Sides: 2 in. (51 mm)*** Vent: 0 in. | Top: 2 in. (51 mm)* Bottom/Ground: 12 in. (305 mm) Front: 0 in.** Back: 0 in. Sides: 2 in. (51 mm)*** Vent: 0 in. |
* 0 in. from vent components.
** Clearance for servicing is 24 in. (610 mm) in front of water heater.
*** Add 0.25 in. (6.35 mm) for recess box.
¹ Activation flow rate may vary slightly depending on the temperature setting and the inlet water temperature.
² The maximum gas supply pressure must not exceed the value specified by the manufacturer.
Rinnai products are continually being updated and improved; therefore, specifications are subject to change without prior notice.
SENSEITM RXP Water Flow Curve
A graph illustrating water flow rates (GPM) versus temperature rise (Delta T in °F and °C). The curves show the performance for RXP199i and RXP160i models at various temperature increases. Note: Maximum flow rates can be influenced by set temperature, Delta T, and altitude. These flow curves are applicable for incoming water temperatures of 70° F (21° C) or less. For incoming water temperatures exceeding 70° F (21° C), please contact Rinnai.
SENSEITM RXP Dimensions
Diagrams showing the physical dimensions of the unit.
FRONT VIEW: Width 18.5 in. (470 mm), Height 25.75 in. (654 mm), Depth 11.41 in. (290 mm).
SIDE VIEW: Width 6.08 in. (154 mm).
BOTTOM VIEW: Shows connection ports:
- Vent Connection: 2 in. (51 mm) nominal PVC/CPVC/PP or 3 in./5 in. Concentric.
- Connection Ports: COLD (A: 0.37 in., B: 3.60 in., C: 5.10 in.), HOT (D: 6.20 in., E: 5.60 in.), GAS (F: 2.83 in.), DRAIN (G: 7.13 in., H: 5.32 in.). Dimensions are in inches (mm).
SENSEITM RXP Pump Performance and Pump + Tankless Performance Curve
A graph displaying Total Head (ft) against Water Flow (GPM), with lines representing different pump settings: MAX, HIGH, MEDIUM, and LOW. This illustrates the pump's performance characteristics.
Recirculation Pump Control
- ✔️ Smart-Circ.™: Learns user hot water patterns to activate recirculation.
- ✔️ Manual schedule selection is available with Accessory controllers (MC-195T or Wi-Fi module).
Internal Multi-Speed DC Pump
The integrated pump facilitates recirculation via a dedicated return line or through a crossover with the thermal bypass valve.
Maximum Recirculation Pipe Lengths
- ✔️ 400 equivalent feet for 3/4 in. pipe diameter
- ✔️ 100 equivalent feet for 1/2 in. pipe diameter
Note: Equivalent elbow lengths should be considered when calculating pipe length. For dedicated return lines, the total length includes both the hot water supply and the dedicated return lines. For cross-over mode, the total length includes both the hot water supply and the cold water piping length from the tankless water heater to the thermal bypass valve. Cross-over mode requires the use of a thermal bypass valve (included).