Rinnai RUR199i & RUR160i
Indoor Condensing Tankless Water Heater
Product Overview
The Rinnai RUR199i and RUR160i are super-high-efficiency, condensing tankless water heaters designed for indoor installation, including manufactured and mobile homes. They feature integrated recirculation pumps and Rinnai's Circ-Logic technology for on-demand hot water.
Key Features
- Integrated recirculation pump for faster hot water delivery.
- Circ-Logic technology for customizable recirculation patterns.
- ThermaCirc360® for hot water availability when needed.
- Flexible venting options (Concentric, PVC/CPVC, Direct Vent, Non-Direct Vent, Common Vent).
- High altitude approval up to 10,200 ft.
- ENERGY STAR® certified.
- Ultra Low NOx emissions.
- Wi-Fi technology for remote monitoring and management.
- Compact design for space saving.
Flexible Venting Options
These units offer versatile venting solutions:
- Concentric or Schedule 40 PVC/CPVC
- Direct Vent (Concentric and Twin Pipe)
- Non-Direct Vent (Room Air)
- Common Vent (Direct Vent and Room Air)
Maximum Equivalent Vent Lengths
Vent Type | Vent Sizes | Vent Lengths |
---|---|---|
Twin Pipe | 2 in. (51 mm) | 65 ft (20 m) |
Twin Pipe | 3 in. (76 mm) | 150 ft (46 m) |
Concentric | 2 in. X 4 in. | 65 ft (20 m) |
Concentric | 3 in. X 5 in. | 150 ft (46 m) |
Circ-Logic Recirculation Technology
Rinnai Circ-Logic technology enables users to set recirculation patterns that align with their hot water usage, ensuring hot water is available when needed without continuous circulation. Two modes are available:
Recirculation Modes
- Dedicated Mode: Utilizes a dedicated return line where the integrated pump circulates water from the heater through the return line and back.
- Crossover Mode: For applications without a dedicated return line, ThermaCirc360® technology allows for the installation of a Thermal Bypass Valve (included) at the fixture farthest from the heater. This valve facilitates recirculation.
A diagram shows the Thermal Bypass Valve installed at a fixture, illustrating the crossover mode plumbing.
Specifications
General Specifications
Specification | RUR199i | RUR160i |
---|---|---|
Installation Type | Internal (Indoor) Applications. Manufactured (Mobile) Home Certified | |
Model Numbers | RUR199i (REU-NP3237FF-US) | RUR160i (REU-NP2530FF-US) |
Approved Gas Types | Natural and Propane | |
Efficiency (UEF) | Up to 0.93 | |
Efficiency (EF) | 0.96 | 0.95 |
High Altitude Approved | Up to 10,200 ft (3,109 m) | |
Water Flow Control | Water Flow Sensor, Electronic Water Control and Bypass Control | |
Controller | Standard: MC-91-2US; Required for Recirculation: MC-195T-US or control-r™ Wi-Fi Module (Included) | |
Certifications | AHRI, ANSI Z21.10.3, CSA 4.3, and ENERGY STAR® | |
Warranty | Heat Exchanger: 15 years or 12,000 hours; Other Parts: 5 Years; Labor: 1 Year | |
Safety Devices | Flame Failure Rod, Boiling Protection, Combustion Fan RPM Check, Over Current Fuse, Remaining Flame (OHS), Automatic Frost Protection | |
Included with Purchase | Tankless Water Heater, control-r™ Wi-Fi Module, Wall Mounting Bracket, Thermal Bypass Valve, Pressure Relief Valve and Adapter, Isolation Valve Kit, Vent Screens (x2), Vent Screen Screws (x2), Self-Tapping Screws (x2) | |
Additional Features | Mobile Home Certified, Ultra Low NOx, Tankless Rack System™ Compatible, 1/2 in. Gas Line Compatible, Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx Emission Levels |
Technical Specifications
Specification | RUR199i | RUR160i |
---|---|---|
Dimensions (w, h, d) | 18.5 in. x 26.4 in. x 11.4 in. (470 mm x 670 mm x 290 mm) | |
Minimum Gas Consumption (Btu/h) | 15,000 | 15,000 |
Maximum Gas Consumption (Btu/h) | 199,000 | 160,000 |
Flow Rate (Min - Max) | 0.26 - 9.8 GPM (1.0 - 37 L/min) | 0.26 - 8.0 GPM (1.0 - 30 L/min) |
Max Flow Rate with Parameter Adjustment | 11 GPM (42 L/min) | 9 GPM (34 L/min) |
Weight | 73 lb (33 kg) | 71 lb (32 kg) |
Sound Level (Normal) | 49 dB | 48 dB |
Sound Level (Standby) | 84 W | 52 W |
Electrical Freeze Protection | 1.3 W | 1.3 W |
Max Current | 4 Amps | |
Fuse | 10 Amps | |
Temperature Settings | Minimum: 98° F (37° C) Default / 120° F (49° C) Crossover Mode; Maximum: 120° F (49° C) Default / 140° F (60° C) With Parameter Adjustment | |
By-Pass Flow Control | Electronic | |
Gas Supply Pressure | Natural: 3.5 - 10.5 in. w.c.; Propane: 8.0 - 13.5 in. w.c. | |
Ignition System | Direct Electronic Ignition | |
Electronic Connections | Appliance: AC 120 Volts, 60Hz; Temperature Controller: DC 12 Volts (Digital) | |
Water Supply Pressure | Minimum: 50 PSI (Recommended 60-80 PSI); Maximum: 150 PSI | |
Controller Cable | Non-Polarized Two Core Cable (Minimum 22 AWG) | |
Service Connections | Gas Supply: 3/4 in. NPT; Cold Water Inlet: 3/4 in. NPT; Hot Water Outlet: 3/4 in. NPT; Condensate Drain: 1/2 in. NPT | |
Clearances (Top) | 2 in. (51 mm) | |
Clearances (Bottom/Ground) | 12 in. (305 mm) | |
Clearances (Front) | 0 in. (Servicing requires 24 in.) | |
Clearances (Back) | 0 in. | |
Clearances (Sides) | 2 in. (51 mm) | |
Clearances (Vent) | 0 in. |
Dimensions and Connections
The unit dimensions are 18.5 in. wide x 26.4 in. high x 11.4 in. deep (470 mm x 670 mm x 290 mm). Diagrams illustrate the front, side, and bottom views, detailing connection points:
- Front View: Shows overall width and height.
- Side View: Shows depth and vent connection (2 in. nominal PVC/Polypropylene or 3 in./5 in. Concentric).
- Bottom View: Details connection ports labeled A through H for Cold Water, Hot Water, Gas, and PRV (Pressure Relief Valve). Specific measurements for each connection are provided in inches and millimeters.
Water Flow Curve
A graph titled "SENSEI™ WATER FLOW CURVE" plots Water Flow (GPM) against Flow Rate (GPM). It shows performance curves for RUR199i and RUR160i, indicating maximum flow rates may vary based on set temperature, Delta T, and altitude. The curves are applicable for incoming water temperatures of 70° F (21° C) or less.
Pump Performance
A graph titled "SENSEI™ PUMP PERFORMANCE AND PUMP + TANKLESS PERFORMANCE CURVE" plots Head (Feet) against Flow Rate (GPM). It illustrates the Pump Performance Curve and the combined Pump and Tankless Performance Curve at a 140°F set point. The RUR pump operates in a range of 1.05 GPM to 5.30 GPM.
Recirculation Pipe Lengths
Maximum equivalent recirculation pipe lengths are:
- 400 equivalent feet for 3/4 in. pipe diameter.
- 100 equivalent feet for 1/2 in. pipe diameter.
Note: Equivalent elbow lengths should be considered. For dedicated return lines, total length includes both hot water supply and return lines. For crossover mode, total length includes hot water supply and cold water piping from the heater to the thermal bypass valve.
Certifications and Compliance
The Rinnai RUR series is certified by AHRI, ANSI Z21.10.3, CSA 4.3, and is ENERGY STAR® certified. It also meets requirements for low lead content and is certified to ANSI Z21.10.3 - CSA 4.3 standards. Additional certifications include UL Listed and NSF Certified for sanitation and low lead content.
Optional Accessories
A range of optional accessories are available, including Room Air Screens, Condensate Neutralizers, ScaleCutters, Drain Down Kits, additional controllers, pipe covers, recirculation pumps, and Wi-Fi accessories. A full list can be found on rinnai.us.