A GENERAL INFORMATION
Before installing the appliance, read operation and maintenance instructions carefully. Wrong installation and part changing may damage the product or may cause injury on people. GGM Gastro is not responsible for damage to the appliance intentionally, due to negligence, detriments because of disobeying instructions and regulations, or wrong connections. Unauthorized intervention to the appliance invalidates the warranty.
- This instruction manual should be kept in a safe place for future reference.
- Installation should be made in accordance with ordinances and security rules of that country by a qualified service personnel.
- This appliance has to be used by trained person.
- Please turn off the appliance immediately in the event of malfunction or failure. The appliance should be repaired only by authorized service personnel. Please demand original spare parts.
A1 PRODUCT DESCRIPTION
*Professional Vacuum Machine, that provides high efficiency has been designed to be used in industrial kitchens.
Product Code | Dimensions (mm) | Weight (kg) | Packaging Dimensions (mm) |
---|---|---|---|
EMP.VCM.01-GN | 280x495x370 | 36 | 300x515x370 |
A2 TECHNICAL INFORMATION
Code | EMP.VCM.01-GN |
---|---|
Seal surface (mm) | 260x8 |
Pump capacity (m³/h) | 10 |
Power (Kw) | 0.4 |
Operating Voltage (V) | 220 |
Cable (mm²) | 3x1.5 |
Weight (kg) | 36 |
Sticking mouth dimension (mm) | 250 |
A3 TRANSPORTATION
*This appliance can be moved by hand from area to area. Do not crash and drop the appliance while transporting.
A4 UNPACKING
*Please unpack the package according to the security codes and ordinances of current country and get rid from the pack. Parts which contact with food are produced by stainless steel. All plastic parts are marked by material's symbol.
*Please check that all the parts of the appliance had come completely and if they are damaged or not during the shipping.
B INSTALLATION
*Please place the product on a straight and sturdy ground, please take necessary steps against possibility of overturn.
*Technicians who will serve for installation and service for the appliance must be professional on this subject and must have installation and service licenses by the company.
*Connection to Electric Power Supply must be done by an authorized person.
*Please be sure that the voltage connected to the appliance must be equal with the voltage which is on the appliance's label.
[warning] This appliance must be connected to an earthed outlet in accordance with safety rules and standards.
*Appliance's earthing must be connected to the earthing line on the panel which is nearest to the electric installation.
*Connection to the main fuse and leak current fuse must be done in accordance with the current regulations.
*You must fill the vacuum pump with HFV-32 high-speed vacuum pump oil or 32N lubricant before use. (When the machine is placed in a horizontal position, the oil level should keep at 3/4 of the oil window.) When running, the oil level should not be lower than 1/2 height of the oil window. Do not fill with too much oil to avoid overflow.
*The power connection position may be located at a different side, so be sure to do grounding protection before use.
C SAFETY INSTRUCTIONS
- [warning] Do not use the appliance in insufficient lighted place.
- [warning] Do not touch the moving attachments while the appliance operates.
- [warning] Do not install the appliance in the presence of flammable or explosive materials.
- [warning] Do not operate the appliance when the machine is empty.
- [warning] Get the necessary cautions against electric danger.
- [warning] Do not attempt to use the appliance without suitable protective equipment.
- [warning] Because of any reason if there is a fire or flame flare where the appliance is used, turn off all gas valves and electric contactor switch quickly and use fire extinguisher. Never use water to extinguish the fire.
- [warning] The power connection position may be located at a different side, so be sure to do grounding protection before use. All damages because of not having earthing connection will not be covered by warranty.
- [warning] The machine should be placed horizontally in good ventilation without corrosive gas and heavy dust.
D OPERATION
Control Panel:
The control panel includes the following components:
- A: ON/OFF BUTTON (MACHINE START BUTTON)
- B: ON/OFF BUTTON (SWITCH THE DEVICE ON AND OFF)
- C: URGENT STOP BUTTON
- D: WORKING INDICATOR LED
- E: TIME INDICATOR SCREEN
- F: TIME SETTING UP BUTTON
- G: TIME SETTING DOWN BUTTON
- L: 0-1 (CUSTOMIZATION SWITCH)
Operating Instructions:
- Place the device in the plug.
- Press the ON-OFF button to start the appliance.
- Navigate with the up and down buttons on the control panel of the device and specify a vacuum time between (1 and 5) seconds.
- Put the products you want to vacuum in the tub, then close the tub cover. Make sure that the valve cover on the top of the tub cover is correctly installed on the cover and the lid seal completely presses the lid.
- Hold the vacuum hose of the device in such a way that air will not leak onto the valve and press the on-Off buttons to operate the device. (You can operate the device with the 0-1 switch that is on the device.)
- During vacuuming, ensure that the cover touches the container with pressure.
- Pull the rubber cap on the lid to open the vacuum lid.
- Do not vacuum the tub for the second time. Otherwise, you can tear the tub cover from the vacuum multi-weld.
- If hot products are vacuumed, open the 3 filter water discharge valves on the side after each use and empty the water inside.
- Open the cover of the filter box every 15 days according to the usage intensity of the appliance, clean the filters thoroughly, and change them once a year. Otherwise, the vacuum motor may be damaged.
E CLEANING & MAINTENANCE
Cleaning And Maintenance After Every Use:
- Clean the outer surface of the appliance with hot water and then dry.
- Always turn off the appliance and disconnect from the power supply before cleaning.
- Do not use abrasive cleaning chemicals as these can leave harmful residues.
- Do not clean the appliance by spraying water directly; otherwise, electrical parts may get damaged.
- Check the oil level of the vacuum pump from the oil gauge of the device and add oil if there is a decrease.
- Depending on the usage intensity of the device, change the oil of the pump once a year.
PERIODIC CLEANING AND MAINTENANCE:
- Maintenance should be done by qualified personnel. Get the periodic maintenance of the appliance once every 15 days.
- Check if the power cable has any errors. If there is an error at the cable, definitely do not use the appliance. Provide the cable to be changed by authorized technical service.
F TROUBLESHOOTING
Issue | Possible Causes & Solutions |
---|---|
THE APPLIANCE DOESN'T OPERATE |
|
NOT VACUUMING |
|
THE APPLIANCE STOPPED |
|
- If vacuum is not done at suitable quality,
- If any function of security doesn't work,
- [warning] Do not use the appliance.
*If these problems are still ongoing, contact with authorized service.
G SPARE PART LIST- EXPLODING DRAWINGS
The following table lists the spare parts for the GGM Gastro Vacuum Machine, model EMP.VCM.01-GN. The exploded view diagram visually represents the assembly of these parts.
NO | PRODUCT NAME | P.CODE |
---|---|---|
1 | VACUUM PLASTIC | Y.EMP.VCM.01-GN.001 |
2 | VACUUM HOSE | Y.EMP.VCM.01-GN.002 |
3 | 0-1 SWITCH | Y.EMP.VCM.01-GN.003 |
4 | CONTROL CARD | Y.EMP.VCM.01-GN.004 |
5 | HANDLE | Y.EMP.VCM.01-GN.005 |
6 | LOCK | Y.EMP.VCM.01-GN.006 |
7 | CHROME FILTER | Y.EMP.VCM.01-GN.007 |
8 | PAPER FILTER | Y.EMP.VCM.01-GN.008 |
9 | INDICATOR SCREW | Y.EMP.VCM.01-GN.009 |
10 | INDICATOR | Y.EMP.VCM.01-GN.010 |
11 | BALL VALVE | Y.EMP.VCM.01-GN.011 |
12 | SQUARE FAN 80X80 | Y.EMP.VCM.01-GN.012 |
13 | MOTOR | Y.EMP.VCM.01-GN.013 |
14 | MOTOR VIBRATION ARC | Y.EMP.VCM.01-GN.014 |
15 | CONTACTOR DLEM-10 | Y.EMP.VCM.01-GN.015 |
16 | BRACKET | Y.EMP.VCM.01-GN.016 |
17 | SLEEVE | Y.EMP.VCM.01-GN.017 |
18 | TRANSPARENT HOSE | Y.EMP.VCM.01-GN.018 |
19 | INSURANCE | Y.EMP.VCM.01-GN.019 |
20 | FAN SAFETY WIRE | Y.EMP.VCM.01-GN.020 |
21 | FEET | Y.EMP.VCM.01-GN.021 |
22 | BASE FRAME | Y.EMP.VCM.01-GN.022 |