TGM50 Thermostat User Guide
This thermostat is suitable for water heating, electric heating, and boiler systems.
Welcome
Thank you for your trust and support! We have adopted advanced technology and perfect craftsmanship so that your new thermostat will provide you with a suitable temperature environment every day in the future.
Main Functions and Characteristics
- WIFI for Android & Apple iOS
- Full-screen display and touchscreen
- Power-off memory function
- Real-time data save function
- 5+2 or 6+1 or 7days six periods program schedule
- Anti-freezing function
- 3 sensor modes can be setting
- Child lock function
Product Packaging
Model | TGM50-EP | TGM50-WP | TGM50-WPB |
---|---|---|---|
Thermostat | ✔️ | ✔️ | ✔️ |
User Manual | ✔️ | ✔️ | ✔️ |
Screws *2 | ✔️ | ✔️ | ✔️ |
External sensor | ✔️ |
Model Spec
Model | Current Loading | Week Program | Controlled Objects |
---|---|---|---|
TGM50-EP | 16A | ✔️ | For electric heating appliances |
TGM50-WP | 3A | ✔️ | For water heating appliances |
TGM50-WPB | 3A | ✔️ | For boilers connected via dry contact |
Technical Parameter
Parameter | Value |
---|---|
Power Supply | AC 100-240V, 50/60Hz |
Current Load | ≤3A (water heating/gas boiler), ≤16A (electric heating) |
Power Consumption | <1W |
External Material | PC+ABS (flame retardant) |
Sensing Element | NTC |
Set Temp. Range | 5-95°C |
Temperature hysteresis | ±1°C (Defaults adjustable 0.5-10°C) |
Dimension | 86x86x12.5mm |
Ambient Temp. | 0-45°C, 5-95%RH (Non-condensing) |
Storage Temp. | -5~55°C |
Timing Error | <1% |
User Notes
- Please read this manual carefully. Improper operation may damage the product or cause dangerous conditions.
- The installation personnel must be well-trained and experienced service technicians.
- After installation, please read this manual carefully and operate the product according to the instructions.
Caution: Risk of electric shock
Wiring Diagram
TGM50-EP: For electric heating. Connections: L, N, N, L, RT. Rated 16A.
TGM50-WP: For water heating (External sensors cannot be connected). Connections: L, N, open, close. Rated 3A.
TGM50-WPB: For boilers connected via dry contact. Connections: L, N, Dry Contact, RT. Rated 3A.
Installation Instruction
This product is suitable for standard 86*86mm wall box and 60 mm european round box.
- Connect the power box according to the wiring diagram.
- Separate the power supply from the control board cable.
- Screw the power supply into the box of 86.
- Connect the power board to the board line, and align the buckle at 30 degrees to complete the installation.
Description of Display & Icons
The thermostat display shows various icons and information:
- ? WIFI icon
- ⏰ Clock icon (Auto mode)
- ✋ Hand icon (Manual mode)
- Room temperature / Setting temperature display
- ⏻ Power button icon
- SET button
- [M] Mode button
- ⬇️ Down arrow button
- ⬆️ Up arrow button
- ? Heating icon
- ? House icon (likely related to home/away or program status)
- Open window detection indicator
- Leave mode indicator
- ? Locking icon
Operation Instruction
- Power on/off: Press the ⏻ button to turn on/off the thermostat.
- Set Temperature: Press the ⬆️ or ⬇️ buttons to set the temperature.
- Switch modes: Press the [M] key to switch between Manual and Leave mode. Manual mode means non-programmable mode, indicated by the ✋ icon. Leave mode sets the temperature to 16°C, indicated by the ? icon. To change to programming mode, use the Tuya Smart or Smart Life APP.
- Set the Child Lock: Simultaneously press the ⬆️ and ⬇️ buttons for 5 seconds to add or cancel the child lock.
- WiFi link: In power on state, press and hold the ⬆️ button for 5-8 seconds. The Wi-Fi icon (?) will flash on the thermostat display, and the thermostat enters the Wi-Fi configuration state.
Time Programming Instructions
Please set up via Tuya Smart or Smart Life app.
Period | Period Icon | Defaulted Time | Defaulted Temp. |
---|---|---|---|
Working day | 1 | 6:00 | 20°C |
2 | 8:00 | 16°C | |
3 | 11:30 | 16°C | |
4 | 12:30 | 16°C | |
5 | 17:00 | 22°C | |
6 | 22:00 | 16°C | |
Rest day | 1 | 8:00 | 22°C |
2 | 23:00 | 16°C |
Remark:
- The defaulted temperature of period 3 and period 4 is the same as period 2. Please change it according to the request.
- Do not set the last time point in the day beyond 23:59.
Advanced Option Setting
In the state of power-off, press the [M] key and the ⬇️ key for 5 seconds to enter the advanced option setting. Press [M] key to enter the next option, press ⬆️ and ⬇️ to adjust, and press ⏻ to save and exit.
Display Code | Function | Setting And Options | Factory Defaults |
---|---|---|---|
01 | Temperature calibration | -9.9-9.9°C | -2°C |
02 | Sensor selection | IN: Use the internal sensor OUT: Use the external sensor ALL: Use both internal and external sensors. | IN |
03 | Limit temperature value modification | 35-60°C | 60°C |
04 | Temperature hysteresis | 0.5-10°C | 1°C |
05 | Antifreeze function | OFF: Close anti-frozen ON: Open anti-frozen | OFF |
06 | Weekly programming mode setting | 7: 7 working days 6: 6 working day+1 rest day 5: 5 working day+2 rest day OFF: turn off programming | 5 |
07 | Main and auxiliary reverse selection (optional) | 00: close the main and auxiliary reversal function 01: indicate the auxiliary reversal ATT: it is not recommended to adjust without professional guidance | 00 |
08 | Standby backlight brightness | 00: turn off the backlight 01: low brightness 02: medium brightness 03: high brightness | 03 |
09 | Set temperature upper limit | 15-95°C | 60°C |
10 | Sound | ON: turn on the sound OFF: turn off the sound | ON |
11 | Window opening detection | ON: turn on the function OFF: turn off the function | ON |
12 | Power outage memory function | 0: Thermostat switch status is the same as before power failure 1: Thermostat opens after power restoration 2: Thermostat closed after power restoration | 0 |
13 | Reset | Long press ⬆️ button. After the drop sound, press the ⏻ button to exit. Thermostat completes reset. |
Notes
- 02 Sensor selection: If no external sensor is connected, do not set it to OUT or ALL, otherwise [Error] will appear on the screen. The thermostat will stop heating until the problem is solved. If there is an error of sensor, [Error] will also appear on the screen.
- 05 Antifreeze function: If Antifreeze function is turned on, when you turn off the thermostat, the room temperature and ⏻ key are still displayed.
- 11 Window opening detection: When the window opening detection is turned on, if the room temperature drops by 6°C within 4 minutes, then window opening mode will be triggered. At this time, the thermostat will stop heating, and the window opening detection icon will be displayed. After the window opening mode is triggered, the mode will be exited under the following three conditions: 1. The room temperature rises by 3°C. 2. 48 minutes after triggering. 3. Manual reset.
Phone Port Operation Instruction
Preparation before Wi-Fi connection
APP download and account registration:
1. Download APP
For iOS system: Login in App Store, search "Tuya Smart", you can download it on your iPhone.
For Android system: Login in Google Play, search "Tuya Smart", you can download it on your phone.
Or scan below code to download: [QR code placeholder]
2. Register Account
If you do not have an APP account yet, you can choose to register or log in via SMS verification code. Click "Create a new account", you will enter the Tuya Smart Platform Privacy Policy page.
After you click Agree, you will officially enter the mobile phone registration page.
The system automatically determines the current country/region. You can also select the country/region manually. After entering your mobile phone number or email address, click "get verification code". Enter the received verification code, then enter the password, and click "Finish" to register successfully.
WIFI connection
1. Turn on your mobile phone's Bluetooth and Wi-Fi
(Please make sure your mobile phone connects to 2.4Ghz Wi-Fi)
2. Activate the thermostat Wi-Fi module
When the thermostat is turned on, press and hold the ⬆️ button for 5 seconds. The Wi-Fi icon (?) flashes on the thermostat display, and the thermostat enters the code matching state.
3. Add Device
There are 3 ways to add a device:
Method 1: Enter the Tuya APP. The main page automatically pops up "Device to be added" (as shown in picture 1) and click "Add".
Method 2: Enter the Tuya APP. Click "Add Device" or "+" (as shown in picture 2) on the upper right corner of the APP homepage, and enter the "Add Device" interface. It will prompt: find the device to be added (as shown in picture 3) and follow the prompts.
Method 3: Enter the Tuya APP. Click "+" on the upper right corner of the APP homepage. Find the temperature control product (Bluetooth + WIFI model) in the "Small household appliance" category (as shown in picture 4). As shown in picture 5, ignore the content of the page and tap Next.
As shown in picture 6, ignore the content of the page and click Next. As shown in picture 7, tick "Confirm the indicator is blinking" and click Next.
4. Enter Wi-Fi information
Enter the name and password of the 2.4Ghz Wi-Fi (please make sure that the Wi-Fi name and password contain only numbers and letters and not special symbols).
Follow the prompts to the next step. You can see the device is being added, and after a few seconds, you will see that the device is added successfully (the length of time will depend on the strength of the Wi-Fi signal).
Display of Temperature Controller APP Interface
The Tuya Smart APP interface allows for manual mode control, displaying current temperature and output status. The settings menu provides access to various configurations including working day settings, week programming, sound, backlight brightness, temperature calibration, maximum setting temperature, temperature control switch difference, external sensor temperature limit, sensor selection, frost protection, output main reverse, and restore factory settings.
If you encounter any problems during the use of the product, please feel free to contact the purchase platform. The company will try its best to help you.