BEOK TGM50 Thermostat User Guide
Welcome
Thank you for your trust and support! BEOK has adopted advanced technology and perfect craftsmanship to provide you with a suitable temperature environment daily. This thermostat enhances your life, making your living environment more pleasant, artistic, and fashionable.
For detailed instructions on installing and using this thermostat, please read this manual carefully. It is recommended to have a professional install the thermostat. Please install and use this product within the scope of the law.
Application
The intelligent digital thermostat is designed for floor heating systems, suitable for room temperature control and household temperature management. It controls the operating status of floor heating equipment by sensing the comparison between ambient and set temperatures. While improving comfort, it achieves energy saving purposes.
The digital thermostat utilizes microcomputer control technology, featuring an elegant design and ease of use. It offers manual, automatic, programmable, and state memory functions.
Product Package
- Thermostat host: 1 pc
- Guide/manual: 1 pc
- Certificate of conformity: 1 pc
- Screw: 2 pcs
- External sensor (optional): 1 pc
Electrical Specifications
Temperature Sensor | NTC |
Temperature accuracy | ±1°C |
Display screen | LCD |
Working environment | -5~50°C |
Self-consumption power | Less than 1W |
Temperature setting | 5~60°C |
Display range | 0~51°C |
Load current | Water heater: 3A Electric heater: 16A Gas boiler: 3A |
Voltage | AC 100-240V, 50/60Hz |
User Instructions
- Read this manual carefully. Improper operation may damage the product or cause a dangerous situation.
- Installation personnel must be well-trained and experienced service technicians.
- After installation is complete, please close this manual carefully and operate the product following the user guide.
Note: There is a risk of electric shock or equipment damage.
Wiring Diagram
Note: WP for water heating; EP for electric heating; WPB for gas boiler
Shows connections for Line (L), Neutral (N), Room Sensor (R), Floor Sensor (S), and Boiler/Valve output (W1, W2).
Shows connections for Line (L), Neutral (N), Floor Sensor (S), and Load output (L1, L2) rated for 16A.
Shows connections for Line (L), Neutral (N), Room Sensor (R), Floor Sensor (S), and Gas Boiler output (W1, W2) rated for 3A.
Mounting Steps
- Connect the power box according to the wiring diagram.
- Separate the power supply from the control board cable.
- Screw the power supply into the 86-type wall box.
- Connect the power board to the control board line, aligning the buckle at 30° to complete the installation.
Icon Description
- WIFI icon: ? [Wi-Fi]
- Manual mode: [Manual]
- Room temperature / Setting temperature: [Temp]
- Button icon: [Button]
- Locking icon: ? [Lock]
- Heating icon: ? [Heating]
- Auto mode: [Auto]
- Leave mode: [Leave]
- Open window detection: ? [Window]
Operation Guide
- Power on/off: Press the power button to turn the thermostat on or off.
- Mode switch: Press the [M] button to switch between Manual and Leave modes.
- Child lock: Simultaneously press and hold the [+] and [-] buttons for 5 seconds to add or cancel the child lock.
- Wi-Fi link: When the thermostat is turned on, press and hold the [Wi-Fi] button for five seconds. The Wi-Fi icon will flash on the thermostat display, indicating it has entered the Wi-Fi configuration state.
Time Programming Instructions
Period | Time | Temp (°C) | Temp (°C) | Temp (°C) | Temp (°C) |
---|---|---|---|---|---|
1 | 6:00 | 18 | 18 | 18 | 18 |
2 | 8:00 | 22 | 22 | 22 | 22 |
3 | 12:00 | 18 | 18 | 18 | 18 |
4 | 17:00 | 22 | 22 | 22 | 22 |
5 | 22:00 | 16 | 16 | 16 | 16 |
6 | 23:00 | 16 | 16 | 16 | 16 |
7 | 0:00 | 16 | 16 | 16 | 16 |
8 | 0:00 | 16 | 16 | 16 | 16 |
Advanced Option Setting
In the [Power Off] state, long press the [M] and [Up] buttons for 5 seconds to enter the advanced option setting.
Press the [M] button to enter the next option, then press the [Up] or [Down] button to adjust options. Press the [Exit] button (implied, or a dedicated key) to exit the advanced option setting mode.
- 01 Temperature compensation: The default value of the calibration room temperature is -2°C. Adjust the range from -9.9°C to +9.9°C using the [Up] or [Down] buttons.
- 02 Sensor selection: The temperature sensor selection defaults to IN (internal sensor). Use [Up] or [Down] to adjust to IN, ALL (all internal sensors), or OUT (external sensors).
- 03 Limit temperature value modification: The limit temperature value defaults to 60°C. Adjust the range from 35°C to 60°C using the [Up] or [Down] buttons.
- 04 Temperature accuracy: The default setting accuracy is ±1°C. Adjust the range from 0.5°C to 10°C using the [Up] or [Down] buttons.
- 05 Antifreeze function: The default setting is OFF. Press the [Up] button to turn the function ON. ATT: If Antifreeze function is turned on, the room temperature and power key will still be displayed when the thermostat is turned off.
- 06 Rest day selection (optional) and closing weekly program: Options include 5: Two-day weekend, 6: Single day off, 7: No rest, OFF: Turn off programming.
- 07 Main and auxiliary reverse selection (optional): The default setting is 00 (main reverse). Press [Up] or [Down] to adjust to 00 (main reverse) or 01 (auxiliary reverse). ATT: It is not recommended to adjust without professional guidance.
- 08 Standby backlight brightness: Options are 00: Turn off the backlight, 01: Brightness always on (Low), 02: Brightness always on (Mid), 03: Brightness always on (High). The default setting is 03.
- 09 Set temperature limit: Set the upper limit of the temperature from 15°C to 95°C. The default is 60°C.
- 10 Sound: Turn ON or OFF the sound.
- 11 Window opening detection: Turn ON or OFF the window opening detection. The default setting is ON. ATT: When window opening detection is turned on, if the room temperature drops by 6°C within 4 minutes, the window opening mode will be triggered. The thermostat will stop heating, and the window opening detection icon will be displayed. The mode exits if the room temperature rises by 3°C, after 48 minutes, or manually.
- 12 Power outage memory function: Options are 0: memory function, 1: Turn on after turning on the power, 2: Turn off after turning on the power.
- 13 Reset: Set to restore factory settings. The default display is "-". Press the [Up] button to display "--_", and then press the [Enter] key to restore factory settings.
About Wi-Fi Connection
Before using the Wi-Fi temperature controller for the first time, you must set the Wi-Fi value number and configuration via your smartphone or tablet to enable communication between your connected devices.
WIFI connection: When the thermostat is turned on, press and hold the [Up] button for 5 seconds. The Wi-Fi icon will flash on the thermostat display, and the thermostat will enter the code matching state.
Wi-Fi connection (Bluetooth thermostat): Please turn on your phone's Bluetooth.
- APP download: Search for “Tuya Smart” in your app market or scan the provided QR code to download the software.
- Register an account: If you do not have an APP account, you can register or log in via SMS verification code. Click "Create New Account" to enter the privacy policy page of the Tuya Smart Platform. After clicking "Agree", you will be directed to the registration page for your mobile phone number. The system automatically determines the current country/region, or you can manually select it. Enter your phone number or email address and click "Get the Verification Code". Enter the received verification code, then enter your password. Click "Finish" to register successfully.
- Add device:
- 3.1: (Bluetooth connection): Turn on your mobile phone's Bluetooth, turn the device on, and open the Tuya APP. Click "Add Device" or "+" on the top right of the APP homepage to enter the "Add Device" interface. It will prompt you to find the device to be added (Figure 2) and follow the prompts.
- 3.2: "Automatic discovery": Search for devices (Figure 3) and add widgets as prompted on the phone page.
- 3.3: (WIFI connection): When the thermostat is turned on, press and hold the [Up] button for 5 seconds. The thermostat display will show the Wi-Fi icon flashing (slowly), indicating the thermostat has entered the code matching state. Find the temperature control product (Bluetooth + WIFI model) under "Small Household Appliances". In the specific network configuration mode, click the confirmation button on the page, select the Wi-Fi network that can connect to the internet in the device's working area, and enter the Wi-Fi password. Click "Next", then click according to the page prompt (Figure 2), "Go to connect". Follow the instructions to find the prompt content (Figure 3), click "Prompt content", and then return to the Tuya APP to enter the network configuration process.
- Thermostat APP interface display: If the network configuration is successful, the APP will display the interface shown in Figure 2. You can modify the device name and select the room's location. If the network configuration fails, the APP will display the page shown below, allowing you to choose to add again or view help. Note: Please confirm whether the thermostat has entered the code matching state if the connection fails.