Buderus FM448 Centralized Alarm Output Function Module

Brand: Buderus

Document Type: Wiring Diagram / Technical Specification

Module and System Overview

Module Front View

A schematic representation of the module's front panel is displayed.

Legend

Control voltage: 120V~

Low voltage for sensors

The system includes an "internal BUS inside controller" which the FM448 module connects to.

FM448 Centralized Alarm Module

FM448 Centralized Alarm Unit

This is the core component, featuring terminals labeled:

Terminals: ZW, GFS, UA, U

Terminal Numbering: 1, 2 (for ZW); 1, 2 (for GFS); 2, 3, 4 (for UA/U, specific assignment not fully detailed for UA/U block)

Connections:

Power supply for additional modules (input or output) connects to the FM448 unit.

Input and Output Connections

Centralized Alarm Output (AS)

Connected via cable AWG14.

Specifications: Contact load 120V, maximum 8A.

Input/Output Terminals (via AWG18)

Cables labeled AWG18 connect to the following inputs and outputs:

  • Heat meter input (ZW): Type: dry contact.
  • Input Fluid level limit sensor (GFS): Type: dry contact.
  • Input 0-10V (U)4: Accepts a 0-10V analog signal.
  • Output 0-20mA (U): Provides a 0-20mA analog signal.

Power Supply for Additional Modules

A separate terminal block is shown for "Power supply for additional modules (input or output)".

This block has connections for AS, N, L, 1, 2, 4, indicating power distribution capabilities.

PDF preview unavailable. Download the PDF instead.

201001222045590.6720619478 fm448-wiring Acrobat Distiller 8.1.0 (Windows)

Related Documents

Preview Buderus FM443 Solar Module Wiring Diagram and Technical Overview
Detailed wiring diagram and technical specifications for the Buderus FM443 solar module, part of the series 4000 controllers, outlining switch modes, connections, and component integration.
Preview Buderus FM441 Function Module Wiring Diagram and Technical Overview
Detailed wiring diagram and technical information for the Buderus FM441 function module, covering heating circuits and domestic hot water (DHW) heating systems. Includes component connections and switching states.
Preview Buderus Logamatic 2107 Controls: System Wiring Diagrams and Configuration Examples
Detailed guide to Buderus Logamatic 2107 control system configurations, including wiring diagrams, module descriptions (FM242, FM244), and system examples for heating and solar applications.
Preview Buderus Boiler Control Panel R4321/R4322 Wiring Diagram and Installation Notes
Detailed wiring diagram and installation notes for the Buderus R4321/R4322 boiler control panel, covering module connections, sensor inputs, and system examples for optimal heating system integration.
Preview Buderus R 4321/4322 Boiler Control Panel Wiring Diagram and Technical Overview
Comprehensive wiring diagram and technical guide for the Buderus R 4321/4322 boiler control panel. Details component connections, module functions, system examples, safety notes, and operational parameters for efficient boiler automation.
Preview Buderus SM10 Solar Module for EMS Wiring Diagram
Detailed wiring diagram for the Buderus SM10 Solar Module, designed for Energy Management Systems (EMS). Illustrates connections for mains power, solar pump, temperature sensors, and other system components.
Preview Buderus FM442 Function Module Wiring Diagram for Two Heating Zones
Detailed wiring diagram and technical information for the Buderus FM442 function module, designed for controlling two heating zones. Includes component connections, switching states, and installation notes.
Preview Buderus ZM433 Central Module Wiring and Installation Guide
Detailed wiring diagram and installation notes for the Buderus ZM433 central module, CM431 controller module, and NM482 power module, including system examples for stand-alone heating and substations.