Hochiki FireNET L@titude - Analog Addressable Fire Alarm Control Panel

Description

The all new L@titude product range of fire alarm control equipment combines the very latest hardware and software to produce a control and indication system, which is powerful and sophisticated, yet simple to use and understand. The flexibility of the L@titude platform is such that it can be re-configured to realize many other control and indication applications, with direct integration into intelligent buildings.

Moving away from the simple, price driven competitive model used by most manufacturers today, the L@titude concept is designed to add value to System Designers, Integrators, Service Providers, and end users. Developed from the “ground up” and using some of the most advanced technology available, L@titude is designed as one of the most powerful, intelligent, and technically robust fire alarm products available.

Not only do the products and services offered under the L@titude brand provide solutions to the most technically challenging applications in life safety, L@titude will deliver added value, market advantage, and a competitive edge to your business.

Product Listings

[UL Listed], [FM Approved]

Manufactured by Kentec Electronics Ltd., Dartford, DA11JQ, United Kingdom

California State Fire Marshal 7165-0410:0506

Specifications subject to change without notice.

Standard Features

Panel Configurations

Image shows three panels. The leftmost is a black single-aperture panel. The middle is a silver single-aperture panel. The rightmost is a red single-aperture panel. All feature a screen and buttons.

Image shows two panels. The left is a silver panel labeled 'Single Aperture'. The right is a silver panel labeled 'Double Aperture', which includes a Zone LED Module and Printer.

Optional Panel Peripherals

Technical Specifications

2 to 8 Loop (4 Slot) Enclosure

AttributeStandard CabinetDeep Cabinet
Size420mm (W) x 590mm (H) x 153mm (D), or 16.5in (W) x 23.2in (H) x 6in (D)420mm (W) x 590mm (H) x 203mm (D), or 16.5in (W) x 23.2in (H) x 8in (D)
ConstructionMild sheet steel enclosure, 1.5mm, 16 gauge
Cable Entry28 knockouts top, 19 knockout back, 1 knockout each side, 2 knockout bottom38 knockouts top, 19 knockout back, 1 knockout each side, 2 knockout bottom
Optional Semi-Flush Mounting KitKM5FCRD - Red, KM5FCGY - Gray, KM5FCBS - Black
Battery CapacityUp to 28 Ah (Power Sonic PS-12280)Up to 40 Ah (Power Sonic PS-12400)

2 to 16 Loop (8 Slot) Enclosure

Attribute8 Slot Standard Cabinet8 Slot Deep Cabinet
Size540mm (W) x 720mm (H) x 160mm (D), or 21.3in (W) x 28.3in (H) x 6.3in (D)540mm (W) x 720mm (H) x 212mm (D), or 21.3in (W) x 28.3in (H) x 8.3in (D)
ConstructionMild sheet steel enclosure, 1.5mm, 16 gauge
Cable Entry38 knockouts top, 25 knockout back, 2 knockout each side, 2 knockout bottom50 knockouts top, 25 knockout back, 2 knockout each side, 2 knockout bottom
Battery CapacityUp to 28 Ah (Power Sonic PS-12280)Up to 40 Ah (Power Sonic PS-12400)

All Models

AttributeSpecification
FinishEpoxy powder coated
ColorLid & Box - Red, Gray or Black; Control Plate - RAL7016
Power supply voltage120 V AC or 240 V AC
Power supply rating at 24V DC5.25 A (charges up to 60 Ah) / 10.25 A (charges up to 100Ah)
DisplayFull color 800 x 480 LCD with resistive touch screen and automatic backlight dimming
Software zones2,000
Software groups5,000
Cause and Effects5,000
Event log10,000 events, 1 second resolution. Filterable and printable
Detection loops2 to 16 added 2 at a time (S758 dual loop cards)
Detection loop current400 milliamps each (NOTE: Each detection loop can display a maximum of 5 devices in Alarm or Activated state*)
AUX 24V Output2; each rated at 900 mA
NACs4; each rated at 2.5A (1.3A for System Sensor devices). 4 Class B or 2 Class A
Programmable Relay Outputs5; 30 V DC 1 Amp
Programmable Inputs3; designed to be activated by voltage-free contacts
Network ConnectionsOptional network card provides communication for networking 127 fire control panels
NAC SynchronizationInternal Support of System Sensor, Wheelock, Gentex and Amseco protocols
Printer (OPTIONAL)40 column, front-loading thermal
Zone LED Indicators (Optional)Up to 3 banks of 48 (144) as standard
Number of Nodes on a Network2 - 127, 127 is the maximum number of nodes on a network, UL Listed

Electrical Specifications

Part NumberModelNameStandby CurrentAlarm CurrentNotes
See Below*L@titude Control Panel.350A.450A*Current draw includes LCD main processor board, main back board, System A board, and System B boards only*
See BelowVision Annunciator.341A.341A
0101-02710S40810.25A Power Supply.080A.080A
0101-02690S4065.25A Power Supply.078A.078A
0101-01220S723Network Module.080A.080AFigures exclude SLC devices
0101-01230S758Dual Loop Module.115A.115A
0101-01280S788Media Gateway Module.114A.114A
0101-01250S7918-Channel Relay Module.010A.160AAlarm all 8 relays active
0101-01330S771Zone LED Module.005A.005A+.003A per active LED
0101-01290S768Thermal Printer.000A1.500A

Model Number Configuration

The model number is constructed from several components, allowing for customization of the panel. The general format is LA 103H# - 14 (abcd), where:

Panel OptionValid EntriesDescription
Product StyleLA, LFLA: FireNET L@titude; LF: FireNET L@titude Vision Repeater
Enclosure Style1, 2, 3, 4, 5, 6, 7, 8, 9, A, CDefines the size and type of enclosure (e.g., 4 Slot Standard, 4 Slot Deep Plex-Door, 8 Slot Rack Mount, 8 Slot Deep Plex-Door).
Language0, 1, 2, 3Specifies the interface language: 0=English, 1=Portuguese, 2=Spanish, 3=Taiwanese.
Power Supply0, 1, 2, 3Options for power supply: 0=None, 1=5.25 A 120V, 2=5.25 A 240V, 3=10.25 A (auto-voltage sensing).
Loop Modules & Communication Modules00, NC, H#, I#, J#, K#Options for modules: 00=Not Fitted, NC=Network Module only (Network Vision Annunciator), H#=2-Loop Panel Module (Hochiki Protocol), I#=2-Loop Panel Module (Hochiki Protocol, and Media Gateway™), J#=2-Loop Panel Module (Hochiki Protocol, and Network Module), K#=2-Loop Panel Module (Hochiki Protocol, Network Module, and Media Gateway™).
Cabinet Color1, 4, 6Color options: 1=Red (RAL3002), 4=Gray (BS 00 A 05), 6=Black (RAL9005).
Printer, Zone LEDs & Aperture0, 1, 3, 4, 5, 6, 7Configuration options for printer and zone LEDs: 0=No Printer / No Zone LEDs, 1=No Printer / No Zone LEDs, Blank 2nd Aperture, 3=Printer / No Zone LEDs, 4=Printer / 48 Zone LEDs, 5=No Printer / 48 Zone LEDs, 6=No Printer / 96 Zone LEDs, 7=No Printer / 144 Zone LEDs.
Optional Peripheral Cardsa, b, c, dSpecific optional modules: a=16 Channel I/O Panel Module (S772), b=8 Channel Relay Panel Module (S791), c=8 Channel Conventional Zone Module (S792), d=4 Channel NAC Module (S793).

If no peripheral cards are ordered, the '(abcd)' portion of the model number should be omitted.

PDF preview unavailable. Download the PDF instead.

FireNET L@titude most updated Microsoft Publisher for Microsoft 365

Related Documents

Preview Hochiki DCP-SOM-AI/DCP-SOM-A Class A Supervised Output Module Installation Instructions
Detailed installation guide for Hochiki America's DCP-SOM-AI and DCP-SOM-A Class A Supervised Output Modules, covering general description, mounting, wiring, specifications, and SCI operation.
Preview FNV 25 / FNV 50 / FNV 100 Voice Evacuation Interface System Installation Instructions
Comprehensive installation guide for the Hochiki FNV 25, FNV 50, and FNV 100 Voice Evacuation Interface Systems. Covers system overview, installation procedures, wiring details, terminal designations, operation, specifications, switch settings, and troubleshooting.
Preview HOCHIKI HCVR-3 Conventional Releasing Fire Alarm Control Panel Datasheet
Detailed specifications and features of the HOCHIKI HCVR-3 Conventional Releasing Fire Alarm Control Panel, including product listings, compatible devices, and technical data. UL Listed and FM Approved.
Preview Hochiki SLR-24V Photoelectric Smoke Detector Technical Specifications
Detailed technical specifications, features, applications, operation, and wiring diagrams for the Hochiki SLR-24V photoelectric smoke detector. Includes product listings and company information.
Preview Hochiki FireNET Graphix: Installation and Programming Manual
A comprehensive guide to installing, configuring, and programming the Hochiki FireNET graphix fire alarm system graphics software. Covers system overview, hardware installation, software setup, running the application, design tools, and utilities.
Preview Hochiki FireNET PLUS Operating Instructions for FN-1127 Control Panel and FN-LCD-S Annunciators
Comprehensive operating instructions for the Hochiki FireNET PLUS FN-1127 control panel and FN-LCD-S annunciators, detailing fire and trouble conditions, button functions, fuse replacement, battery maintenance, and SOM-R releasing function.
Preview Hochiki Product Guide ISS30:MAR24 - Fire Detection Systems & Solutions
Comprehensive product guide from Hochiki, detailing their advanced range of fire detection systems, including addressable, conventional, wireless, and air sampling technologies. Learn about Hochiki's commitment to fire safety innovation.
Preview Hochiki ACE-V Analog Multi-Criteria Smoke/Heat Detector Specifications and Applications
Detailed information on the Hochiki ACE-V Analog Multi-Criteria Smoke/Heat Detector, covering its applications, operation, standard features, product listings, and technical specifications. Includes UL and FM certifications.