Roth MultiPex® Installation

Living full of energy

Introduction

This guide provides essential instructions for the installation of the Roth MultiPex® piping system. It covers critical steps from pipe preparation to final assembly and testing, ensuring a safe and efficient system for drinking water and central heating applications.

1. Pipe Cutting

Roth MultiPex® pipes must always be cut perpendicularly using PEX pipe scissors. Ensure a straight cut surface. Recommended tools and their reference numbers include:

[Diagram 1: Illustration of a pipe cutting tool being used to make a perpendicular cut.]

2. Support Bushings

Always use a Roth support bushing or an approved coupling with an integrated support bushing. This ensures proper pipe support and connection integrity.

[Diagram 2: Shows a support bushing being inserted into the end of a pipe.]

3. Solvent Warning

Do not use products containing solvents on pipes or fittings.

[Diagram 3: A warning symbol with a crossed-out bottle, indicating that solvents should not be used.]

4. Pipe Bending

When bending Roth MultiPex® pipes, ensure a minimum bending radius of 5 times the pipe diameter at 20°C. A maximum of 3 bends per pipe length is recommended (4 bends per pipe run in Norway). For changes in direction from vertical to horizontal guidance, use Roth bending fix or Roth mounting fix. In Finland, for connections to manifolds, taps, or radiators, use a suitable cold bending curve. In systems with up to three 90° bends, a dedicated bending curve may be needed.

[Diagram 4: Illustrates the minimum bending radius for pipes, showing it should be at least 5 times the pipe diameter.]

5. Pipe Fixing (Light Construction)

Pipes must be fixed according to drawings 5A and 5B in light constructions using Roth clamps and fixing accessories. If pipes are insulated, the insulation must be removed at the attachment points.

[Diagram 5A & 5B: Show methods for fixing pipes in light construction using clamps and brackets.]

6. Pipe Fixing (Heavy Construction)

In heavy constructions, pipes must be fixed according to drawing 6. Roth clamps, Roth pipe hooks, or strips can be used. For insulated pipes, remove insulation at attachment points. In heavy constructions in Sweden, observe that protective pipes must not be deformed when fixed with cable ties.

[Diagram 6: Illustrates pipe fixing methods for heavy construction.]

7. Assembly and Testing

Pipes are easily assembled with Roth TT push fittings or EURO distributor pipes into a waterproof Roth Quick cabinet. Pipes can be terminated with Roth Multi-through or Roth QuickBox®. The Roth MultiPex® pipe-in-pipe system must be pressure/tightness tested with water/air before walls are sealed. In Finland, connections to manifolds within cabinets or junction boxes are possible, and the system must be pressure tested with water/air before sealing walls.

[Diagram 7: Shows various Roth accessories for pipe systems, such as fittings and cabinets.]

Technical Data

The following technical data applies to Roth MultiPex® pipes:

Specification Details
Area of Application Drinking water and central heating
Available Pipe Sizes (Diameter x Wall Thickness) 12 x 2.0 mm, 15 x 2.5 mm, 18 x 2.5 mm, 22 x 3.0 mm, 28 x 4.0 mm, 32 x 4.4 mm
Temperature Class 95°C (normal operation 70°C, short term up to 95°C)
Pressure Class 10 bar (1000 kPa)
Material PEX-C
Frost Protection Max 50% Glycol. For other additives, contact Roth support for your region.

Accessories

A range of accessories are available for the Roth MultiPex® system:

Accessory Type Description / Reference Numbers
Pipe Hooks Double 60 mm (DK: VVS-nr. 087253.292), 100 mm single (DK: VVS-nr. 087253.290), 80 mm single (DK: VVS-nr. 087253.288)
Bending Aids Bending Fix 34 mm (DK: VVS-nr. 087251.234), Mounting Fix for 20/25 mm tubes (DK: VVS-nr. 087249.325), Plastic Bending Fix 28 mm (DK: VVS-nr. 087249.228), Plastic Bending Fix 25 mm (DK: VVS-nr. 087249.225), Steel Bending Fix 42 mm (DK: VVS-nr. 087251.242)
Fixing Clamps Clamps for 20 mm (DK: VVS-nr. 087250.320), 25 mm (DK: VVS-nr. 087250.325), 28 mm (DK: VVS-nr. 087250.328), 34 mm (DK: VVS-nr. 087250.334) pipes, all include screws.
Fixation Bracket For 20-34 mm pipes (DK: VVS-nr. 087289.234)
Pipe Hooks (Nordic) Double 14-34 mm (NO: NRF nr. 511 82 26), Single 14-34 mm (NO: NRF nr. 511 82 23)
Fixing Angles (Nordic) 34 mm galvanized (NO: NRF nr. 511 83 63), 20-25 mm RIR (NO: NRF nr. 511 81 27), 28 mm (NO: NRF nr. 511 83 62), 25 mm (NO: NRF nr. 511 83 79), 42 mm galvanized (NO: NRF nr. 511 83 61)
Clamps (Nordic) 20 mm (NO: NRF nr. 511 82 95), 25 mm (NO: NRF nr. 511 82 96), 28 mm (NO: NRF nr. 511 82 97), 34 mm (NO: NRF nr. 511 82 98)
Fixing Clamp (Nordic) For 20-34 mm (NO: NRF nr. 511 82 06)
Pipe Bends (Finland) Steel 34 mm (FI: LVI-nro 2016457), For 20/25 mm protective pipe (FI: LVI-nro 2016497), Plastic 28 mm (FI: LVI-nro 2016452), Plastic 25 mm (FI: LVI-nro 2016451), Steel 42 mm (FI: LVI-nro 2016458)
Pipe Clamps (Finland) 20 mm (FI: LVI-nro 2016560), 25 mm (FI: LVI-nro 2016465), 28 mm (FI: LVI-nro 2016466), 34 mm (FI: LVI-nro 2016467)
Protective Pipe Fixing Plate (Finland) For 20-34 mm (FI: LVI-nro 2016472)
Pipe Hooks (Finland) Double 60 mm (FI: LVI-nro 2016463), 100 mm (FI: LVI-nro 2016462), 80 mm (FI: SAP-nro 17087253.288)
Pipe Bends (UK) Steel 34 mm (UK: HVAC no. 7087251234), Plastic flex 25 mm (UK: HVAC no. 7087249325), Plastic 28 mm (UK: HVAC no. 7087249228), Plastic 25 mm (UK: HVAC no. 7087249225), Steel 42 mm (UK: HVAC no. 7087251242)
Fixing Clamps (UK) 20 mm w-screw (UK: HVAC no. 7087250320), 25 mm w-screw (UK: HVAC no. 7087250325), 28 mm w-screw (UK: HVAC no. 7087250328), 34 mm w-screw (UK: HVAC no. 7087250334)
Fixation Bracket (UK) 20-34 mm (UK: HVAC no. 7087289234)
Pipe Hooks (UK) 60 mm double (UK: HVAC no. 7087253292), 100 mm single (UK: HVAC no. 7087253290), 80 mm single (UK: HVAC no. 7087253288)

Contact Information

Roth Danmark A/S

Centervej 5, 3600 Frederikssund

Tlf. +45 4738 0121

E-mail: service@roth-danmark.dk

roth-danmark.dk

Roth Sverige AB

Höjdrodergatan 22, 212 39 Malmö

Tel. +46 40534090

E-mail: service@roth-sverige.se

roth-sverige.se

Roth Norge AS

Billingstadsletta 19, 1396 Billingstad

Tel. +47 67 57 54 00

E-mail: service@roth-norge.no

roth-norge.no

facebook.com/RothNorge

Roth Finland Oy

Raaseporintie 9, Talo 2, 10600 Tammisaari

Puh. +358 (0)19 440 330

S-posti: service@roth-finland.fi

roth-finland.fi

facebook.com/RothFinland

Roth UK Ltd

Enterprise House, Barracks Road, Stourport-On-Severn, Worcestershire, DY13 9RW

Phone +44 (0) 1905 453424

E-Mail: enquiries@roth-uk.com, technical@roth-uk.com, orders@roth-uk.com, accounts@roth-uk.com

roth-uk.com

Models: 087253.292, 087253.290, 087253.288, 087251.234, 087249.325, 087249.228, 087249.225, 087251.242, MultiPex 15x2 5 mmx15m TG Pipe, MultiPex, 15x2 5 mmx15m TG Pipe, 5 mmx15m TG Pipe, TG Pipe, Pipe

File Info : application/pdf, 6 Pages, 1.14MB

PDF preview unavailable. Download the PDF instead.

Installation Roth MultiPex 20240610

References

Adobe InDesign 19.4 (Windows) Adobe PDF Library 17.0

Related Documents

Preview Roth QuickTemp Gulvvarmesystemer: Energieffektiv Komfort
Opdag Roth QuickTemp gulvvarmesystemer for hurtig reaktionstid, lav byggehøjde og energibesparelser. Ideel til renovering og nybyggeri.
Preview Roth Touchline® SL Thermostat Installation Guide
Comprehensive installation guide for the Roth Touchline® SL room thermostat and underfloor heating system. Learn how to pair, register, and configure your thermostat with floor sensors and controllers.
Preview Roth Basicline Thermostat Cover Installation Guide
Installation instructions for the Roth Basicline thermostat cover, providing guidance for fitting the protective casing onto the thermostat unit.
Preview Roth Touchline® PL Room Thermostat Installation and Operation Guide
This guide provides comprehensive instructions for installing and operating the Roth Touchline® PL wireless room thermostat. It covers setup, pairing with the controller, and detailed explanations of the thermostat's functions and settings.
Preview Roth Touchline® SL Installation Guide
Comprehensive installation guide for the Roth Touchline® SL controller, detailing setup, wiring, configuration, and pairing of thermostats and sensors for underfloor heating systems. Includes safety warnings and contact information.
Preview Roth ShuntUnit Installation Guide - Comprehensive Setup and Technical Details
Detailed installation guide for the Roth ShuntUnit, covering setup, operation, technical specifications, and troubleshooting. Includes multilingual instructions translated into English and part numbers.
Preview Roth Touchline® PL Controller 8 Channels - Installation Guide
Official installation guide for the Roth Touchline® PL Controller, an 8-channel heating control unit. Learn how to safely install, connect actuators, and power up your system.
Preview Roth Touchline SL Plus Room Thermostat Installation Guide
Comprehensive installation guide for the Roth Touchline SL Plus room thermostat, covering setup, pairing with controllers, and floor sensor integration for efficient home heating control.