Roth Touchline® SL Installation

This document provides installation instructions for the Roth Touchline® SL thermostat and its associated underfloor heating system components.

Mounting the Thermostat

Step 1: Detach the Backplate

Gently push the snap lock with a finger or screwdriver (if mounted on the wall) to slide the backplate off the thermostat.

Step 2: Insert Batteries

Insert the included batteries, paying attention to the correct +/- polarity.

Step 3: Mount Backplate

Mount the backplate on the wall (screws not included). Slide the thermostat onto the backplate. Ensure it is securely attached.

Optional: Free-standing Setup

If you wish to use the thermostat as a free-standing unit, the supplied foot can be mounted in the backplate before the thermostat is re-attached.

Connecting a Floor Sensor

Step 4a: Connect Floor Sensor (Optional)

It is possible to connect an optional floor sensor. Gently push on the terminals while inserting the sensor cable. The sensor cable should be run through a conduit, and the sensor tip placed directly beneath the top floor covering, in the middle between the underfloor heating pipes.

Controller Pairing and Registration

Compatibility

The thermostat can be connected to all Controllers in the Roth Touchline® SL series. Pairing/registering is performed identically on all Controllers using the same buttons. The images show the panel of the Roth Touchline® SL Controller, master.

Steps to Register Thermostat (Steps 5-10)

Follow these steps to register the thermostat to a zone (channel) on the controller:

  1. Step 5: View the initial controller display, typically showing date, time, and "No active zones".
  2. Step 6: Access the controller's main Menu, which includes options like "Zones", "Manual mode", "Time settings", and "Language version".
  3. Step 7: Navigate to the "Zones" screen to select a specific zone (e.g., Zone 1, Zone 2, Zone 3, Zone 4).
  4. Step 8: Select the desired zone (e.g., ZONE 1) and initiate the "Registration" process.
  5. Step 9: The controller will prompt: "Do You want to register the sensor?". Select "Yes".
  6. Step 10: The controller will display "REGISTRATION Searching" as it looks for the thermostat.

Step 11: Pairing the Thermostat

Press the pairing button located on the rear of the thermostat. Note: Do not press the buttons on the front of the thermostat while pushing the pairing button on the rear.

Steps to Complete Registration

After pressing the pairing button on the thermostat, follow these steps on the controller:

  1. Press the "OK" button on the controller when prompted.
  2. The controller will display "Sensor registered".

Step 13: Registration Confirmation Display

The controller display will now show detailed information:

  • Date and Time (e.g., Mo. 01.09.20, 20:52)
  • Temperature Settings: Setpoint temperature (e.g., 22.0°C) and Actual temperature (e.g., 25.0°C).
  • Mode of Operation: Indicated by abbreviations like "CON" (Continuous).
  • Battery Status: Shown as a percentage (e.g., 99%).
  • Signal Strength: Indicated as a percentage (e.g., 100% - must be at least 10%).

For more information on the display, consult the controller manual. Repeat the registration process for any additional thermostats on different channels (2 to 8).

Important: If a thermostat is paired to the wrong zone, do not delete it. Simply pair the thermostat to the correct/new zone, and the old pairing will be automatically deleted.

Floor Sensor Registration

Steps to Register Floor Sensor (Steps 14-21)

If the thermostat has a floor sensor connected, it must also be paired/registered. This process is similar to registering the thermostat:

  1. Navigate through the controller menus to "FLOOR HEATING" and then "Registration".
  2. When prompted "Do You want to register the sensor?", select "Yes".
  3. The controller will begin "Searching" for the sensor.
  4. Perform the specific action required for sensor pairing, which may involve two quick presses on a button on the thermostat or sensor unit (as indicated in picture 21).
  5. Confirm the registration when prompted (e.g., by pressing "OK").

Step 22: Sensor Registration Confirmation

The controller display will show "Sensor registered" and "OK" upon successful registration.

Step 23: Overview Display with Floor Sensor

The controller's overview display will now include information for the floor sensor:

  • Thermostat Setpoint Temperature (e.g., 22.0°C)
  • Thermostat Actual Temperature (e.g., 25.0°C)
  • Mode of Operation (e.g., CON)
  • Battery Status (e.g., 99%)
  • Actual Floor Temperature (e.g., 21.0°C)

Repeat steps 14-21 for all other zones/channels (2 to 8) where a floor sensor is connected.

Floor Sensor Settings

Operation Modes: Floor Protection vs. Comfort

Floor sensor settings are configured on the controller. The operation mode can be set to either "Floor Protection" (standard) or "Comfort".

Configuring Floor Protection (Steps 24-27)

  1. On the controller, navigate to "FLOOR HEATING" > "Operation mode".
  2. Select "Floor protection".
  3. Navigate to "Max temperature" and set the maximum floor temperature to protect your floor.
  4. Confirm the settings by pressing "Menu".

Configuring Comfort Mode (Steps 28-31)

  1. On the controller, navigate to "FLOOR HEATING" > "Operation mode".
  2. Select "Comfort".
  3. Navigate to "Min temperature" and set the desired minimum floor temperature for comfort.
  4. Confirm the settings by pressing "Menu". The minimum temperature is set as described.

Priority Explanation

Floor Protection Mode: Heating will stop if the temperature exceeds the set maximum temperature.

Comfort Mode: The room thermostat has priority as long as the temperature is between the set minimum and maximum. Outside these limits, the floor sensor has priority.

Thermostat Operation and Settings

Standby Mode & Temperature Adjustment

In standby mode, the current temperature is displayed. Use the < > buttons to set or change the temperature. Confirm by pressing the button or waiting 5 seconds.

Display Information (Temperature/Humidity)

You can switch between the temperature display and the relative humidity display by briefly pressing the button.

Operation Modes (Con, 5h, OFF)

You can choose between three modes on the thermostat:

  • Con (Constant): The setpoint is active constantly.
  • 5h (5 Hours): The setpoint is valid for 5 hours, after which the thermostat returns to its normal mode.
  • OFF: The thermostat follows the mode preset on the Controller.

Changing the mode (Con, 5h, OFF) is done using the < > buttons when the mode is flashing.

Battery Level Check

To view the battery level, select "Bat". The display will flash, and after confirming within 5 seconds, the battery level is shown as a percentage.

Button Lock

To lock the buttons, select "Yes" using the < > buttons and confirm. When locked, buttons automatically lock after 10 seconds of inactivity. To unlock, press and hold the < > buttons for 10 seconds. The key lock is activated until you deactivate it in the menu.

Factory Reset

To return the room thermostat to factory settings, select "dEF". The display will flash the selected value. Confirm (Yes) within 5 seconds. The factory settings will be restored.

Sensor Calibration

To view the sensor calibration value, select "Cal". The screen flashes for 3 seconds, and the value is displayed. The value can be changed on the Controller; refer to the user manual.

Exiting Menus

To return from the MENU manually, select "rEt". The screen flashes for 5 seconds and returns to the current temperature view.

Contact Information

ROTH UK Ltd

1a Berkeley Business Park
Wainwright Road
Worcester WR4 9FA
Phone: +44 (0) 1905 453424
E-mail: enquiries@roth-uk.com, technical@roth-uk.com, orders@roth-uk.com, accounts@roth-uk.com
www.roth-uk.com

ROTH DANMARK A/S

Centervej 5
3600 Frederikssund
Tlf: +45 4738 0121
E-mail: service@roth-danmark.dk
www.roth-danmark.dk

ROTH SVERIGE AB

Höjdrodergatan 22
212 39 Malmö
Tel: +46 40534090
Fax: +46 40534099
E-mail: service@roth-sverige.se
www.roth-sverige.se

ROTH NORGE AS

Billingstadsletta 19
1396 Billingstad
Tel: +47 67 57 54 00
E-mail: service@roth-norge.no
www.roth-norge.no
facebook.com/RothNorge

ROTH FINLAND OY

Raaseporintie 9 (Talo 2)
10600 Tammisaari
Puh: +358 (0)19 440 330
S-posti: service@roth-finland.fi
www.roth-finland.fi
facebook.com/RothFinland

Models: Touchline SL, Touchline SL Standard Rumtermostat, Standard Rumtermostat, Rumtermostat

File Info : application/pdf, 8 Pages, 1.24MB

PDF preview unavailable. Download the PDF instead.

roth touchline sl standard ohje

References

cairo 1.17.4 (https://cairographics.org) Mozilla Firefox

Related Documents

Preview Roth Touchline SL Plus Room Thermostat Installation Guide
Comprehensive installation guide for the Roth Touchline SL Plus room thermostat, covering setup, pairing with controllers, and floor sensor integration for efficient home heating control.
Preview Roth Touchline® PL Room Thermostat Installation and Operation Guide
This guide provides comprehensive instructions for installing and operating the Roth Touchline® PL wireless room thermostat. It covers setup, pairing with the controller, and detailed explanations of the thermostat's functions and settings.
Preview Roth QuickTemp Gulvvarmesystemer: Energieffektiv Komfort
Opdag Roth QuickTemp gulvvarmesystemer for hurtig reaktionstid, lav byggehøjde og energibesparelser. Ideel til renovering og nybyggeri.
Preview Roth Touchline SL Room Thermostat, IR: Advanced Underfloor Heating Control
Discover the Roth Touchline SL Room Thermostat, IR, an innovative infrared thermostat for underfloor heating. Features dual temperature regulation, wireless convenience, and sleek design options in black or white. Ideal for renovations.
Preview Roth MultiPex® PEX Piping System Installation Guide
This installation guide provides detailed instructions for Roth MultiPex® PEX piping systems. It covers essential steps such as pipe cutting, bending, and fixing, along with warnings about solvent use. The document also includes comprehensive technical data and a list of compatible accessories, presented in English for clarity. Suitable for drinking water and central heating applications.
Preview Roth Touchline® SL Installation Guide
Comprehensive installation guide for the Roth Touchline® SL controller, detailing setup, wiring, configuration, and pairing of thermostats and sensors for underfloor heating systems. Includes safety warnings and contact information.
Preview Roth Project Line Room Thermostat Installation and Operation Guide
Comprehensive installation and operation guide for the Roth Project Line room thermostat. Covers physical installation, pairing with the Roth Project Controller, and detailed explanations of thermostat features and menu options, translated to English.
Preview Roth Basicline 230T Thermostat Installation and User Guide
Comprehensive guide for the Roth Basicline 230T thermostat, covering installation, operation, settings, and troubleshooting. Learn how to optimize your heating and cooling with this 230V thermostat.