Sealey FP8D & FP9D Digital Foot Pumps

Model Numbers: FP8D, FP9D

Introduction

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble-free performance.

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

Safety

Symbol Meanings

  • DANGER! Direct danger to life and risk of injury! Directly dangerous situation that may lead to death or severe injuries.
  • CAUTION! Possible risk of injury! Dangerous situation that may lead to injuries.

General Safety Instructions

  • To operate this device safely, the user must have read and understood these instructions for use before using the device for the first time.
  • Observe all safety instructions. Failure to do so may cause harm to you and others.
  • Retain all instructions for use, and safety instructions for future reference.
  • If you sell or pass the device on, you must also hand over these operating instructions.
  • The device must only be used when it functions properly.
  • If the product or part of the product is defective, it must be taken out of operation and disposed of correctly.
  • Keep the device out of the way of children and other unauthorised persons.
  • DO NOT overload the device.
  • DO NOT use the device for purposes for which it is not intended.
  • Exercise caution and only work when in good condition. DO NOT use if you are tired, ill, ingested alcohol, medication or drugs.
  • This product is NOT intended to be used by persons (including children) or who are limited in their physical, sensory or mental capacities or who lack experience and/or knowledge of the product unless they are supervised, or have been instructed on how to use the product, by a person responsible for their safety.
  • Always comply with all applicable domestic and international safety, health, and working regulations.

Device-Specific Safety Instructions

  • When using for safety-relevant items, for example, car tyres, check the pressure using a calibrated device.
  • For the maximum permitted pressure, observe the manufacturer's guidelines for the item to be pumped.
  • Make sure you are positioned firmly and with a natural stance when working with the device.
  • Only work with good light and visibility.
  • Children should be supervised to ensure that they DO NOT play with the device.
  • DO NOT remove or cover symbols affixed to the tool. Information on the device that is no longer legible must be replaced immediately.

DANGER! Risk of injury! This device may only be put into operation if there are no defects. If a part is defective it must be replaced before the device is used again. Check to make sure the device is in a safe operating condition. Check for visible defects and make sure all components are correctly mounted.

DANGER! Risk of injury! When operating the device, ensure both the user and device are balanced comfortably.

CAUTION! Risk of injury! Only operate the device with your feet, not with your hands. There is a risk of crushing. A jumping pump may cause injuries. A working pump may generate heat. DO NOT touch with bare hands.

Product Description

Steel framed foot pumps with Ø54 x 116mm barrels. Digital gauge calibrated in psi, bar and kPa. Large LCD screen with easy-to-read display. Fitted with flexible hose length with locking connector. Anti-slip rubber feet for control and safety locks for security.

Specification

Model No: FP8D FP9D
Accuracy: ±0.8% ±0.8%
Battery Run Time: Continuous working time: 20 hours Continuous working time: 20 hours
Battery: CR2032 (Supplied) CR2032 (Supplied)
Max. Output Pressure: 140psi 73psi
Nett Weight: 1.54kg 1.92kg
Pressure Units: Bar, psi, kpa Bar, psi, kpa

Operation

  1. Insert the supplied battery on the top of the unit, ensuring correct polarity (see diagram description).
  2. Place the foot pump on a level, stable surface.
  3. Push the foot pad down whilst releasing the safety hooks. Allow the foot pad to slowly rise.
  4. Insert an appropriate adaptor (Schrader/Presta) into the hose connection and lock by applying the locking lever (see diagram description).
  5. Connect the foot pump to the tyre valve.
  6. Use the On/Off button to turn on the digital gauge.
  7. Use the On/Off button to select the display unit (psi, bar, kPa).
  8. Activate the pump evenly with moderate force and allow it to slowly return. Inflate until desired pressure is reached.
  9. Use the safety hook to compress the foot pump after use.

Changing the Battery

Slide the battery tray out to install/change the battery. Ensure you insert the battery the correct way up (see diagram description).

Diagram Descriptions:

  • Figure 1: Illustrates the foot pump's locking mechanism. The 'Locked Position' shows the foot pad secured, while the 'Unlocked Position' shows it ready for use. A lever on the hose connection is shown for securing adaptors.
  • Figure 2: Shows the 'Battery Compartment' located on the top of the unit, the 'Digital Display' which shows the pressure reading (e.g., '0.00 BAR'), and the 'On/Off Button' used for powering the device and selecting display units.
  • Figure 3: Depicts the correct orientation for inserting the CR2032 battery into the compartment, showing the positive (+) and negative (-) sides.

Maintenance

  • Replace the battery when the display no longer functions.
  • Dispose of old batteries in accordance with local regulations.
  • Transport in original packaging.
  • Keep the tyre pump clean by wiping with a damp cloth.
  • DO NOT allow water ingress into the tyre pump.
  • DO NOT use solvents to clean the tyre pump.
  • Store the tyre pump in a well-ventilated and dry childproof area.

Life Time of the Machine / Disposal

Through years of normal wear, the tyre pump will eventually become unserviceable. When this happens, ensure that it is disposed of in accordance with local authority regulations.

Battery Safety

Symptoms that may arise from battery ingestion:

No obvious symptoms. Unfortunately, it is not obvious when a button or coin battery is stuck in a child's oesophagus (food pipe). There are no specific symptoms associated with this. The child might:

  • cough, gag or drool a lot;
  • appear to have a stomach upset or a virus;
  • be sick;
  • point to their throat or stomach;
  • have a pain in their abdomen, chest or throat;
  • be tired or lethargic;
  • be quieter or more clingy than usual or otherwise "not themselves";
  • lose their appetite or have a reduced appetite; and
  • not want to eat solid food/ be unable to eat solid food.

These sorts of symptoms vary or fluctuate, with the pain increasing and then subsiding. A specific symptom to button and coin battery ingestion is vomiting fresh (bright red) blood. If the child does this, seek immediate medical help.

The lack of clear symptoms is why it is important to be vigilant with "flat" or spare button or coin batteries in the home and the products that contain them.

Environment Protection

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids according to local regulations.

Battery Removal

Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products containing batteries (as defined within these regulations), that they are registered with Valpak's registered compliance scheme. Jack Sealey Ltd Batteries Producer Registration Number (BPRN) is BPRN00705.

WEEE Regulations

Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid waste authority for recycling information.

Notes

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

Important: No Liability is accepted for incorrect use of this product.

Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.

Models: FP8D-FP9D Twin Barrel Digital Foot Pump, FP8D-FP9D, Twin Barrel Digital Foot Pump, Barrel Digital Foot Pump, Digital Foot Pump, Foot Pump

PDF preview unavailable. Download the PDF instead.

FP8D FP9D Instructions 20250729 (4) DFC1934147 Adobe PDF Library 17.0 Adobe InDesign 20.5 (Windows)

Related Documents

Preview Sealey TP6818.V2 Electric Drum/Barrel Pump - Instructions and Safety Guide
Official instruction manual for the Sealey TP6818.V2 electric drum and barrel pump. Includes safety warnings, specifications, operation, and maintenance procedures for diesel, AdBlue, antifreeze, and light oils.
Preview Sealey TP98.V2 TP9824.V2 Diesel Fluid Transfer Pump: User Manual, Specifications & Safety Guide
Sealey TP98.V2 and TP9824.V2 diesel and fluid transfer pump user manual. This guide provides detailed instructions on safety, assembly, operation, specifications, performance, troubleshooting, and maintenance for Sealey's 12V and 24V DC transfer pumps.
Preview Sealey TP90.V2 Air Operated Transfer Pump: Instructions and Specifications
Detailed instructions, safety guidelines, specifications, and troubleshooting for the Sealey TP90.V2 Air Operated Transfer Pump. Includes information on operation and chemical compatibility.
Preview Sealey AK450DP Air Powered Pump Away Station - Instructions and Operation
Comprehensive guide for the Sealey AK450DP Air Powered Pump Away Station, covering safety, assembly, installation, operation, maintenance, and troubleshooting. Includes specifications and parts list.
Preview Sealey Surface Mounting Water Pump 50L/min 230V WPS060.V3 Parts Information
Detailed parts information and diagram for the Sealey Surface Mounting Water Pump, Model WPS060.V3, 50L/min, 230V, including a comprehensive parts list.
Preview Sealey TP6809 AdBlue Lever Action Pump - Instructions and Specifications
Comprehensive instructions and specifications for the Sealey TP6809 AdBlue Lever Action Pump. Learn about safety, assembly, operation, and maintenance for efficient fluid transfer.
Preview Sealey BC115D Track Pump with Digital Gauge: User Manual
Instructions and specifications for the Sealey BC115D track pump, a bicycle pump with a digital gauge, 8 bar/180 PSI capacity, and auto-shut-off feature. Includes safety, operation, maintenance, and disposal information.
Preview Sealey TP67 & TP67/X Gear Oil Transfer Pump & Fixing Kit Instructions
Comprehensive instructions and safety information for the Sealey TP67 Gear Oil Transfer Pump and TP67/X Fixing Kit, designed for EP80 Gear Oil Drums. Includes assembly, applications, and warranty details.