Moticam X4 Quick Start Guide

Introduction

Thank you for purchasing this Moticam. This camera is a delicate instrument and should be handled with care. When not in use, please store the camera in a safe place with the dust cap attached. Do not let the camera get in contact with water or expose it to extreme temperatures (below 0 or above 50 degrees Celsius). To receive the highest level of service, please retain your receipt as proof of purchase and register your camera online at www.motic.com today.

Should you have any questions, please do not hesitate to contact our customer service.

Included Parts

How to Use Your Moticam X4

Using the Camera on an Eyepiece

Diagram shows the Moticam X4 camera (A) with focusable lens (D) and eyepiece adapter (E) attached, being mounted onto a microscope eyepiece.

  1. Remove the Dust Cap (B) from the camera (A) and attach the focusable lens (D).
  2. Choose the right size eyepiece adapter (E) and attach this to the focusable lens.
  3. Attach this assembly to your microscope's eyepiece by tightening the centering screws on the eyepiece adapter.
  4. Connect the USB power supply to the camera. When the light on the camera is on, it means the camera is working and transmitting images, and you can connect to it through WiFi.
  5. Connect to the Moticam X4 WiFi signal. Please see the instructions on page 11.

Using the Camera as a Macro Camera

Diagram shows the Moticam X4 camera (A) with focusable lens (D) and macro tube (H) attached, ready to be placed over an object for close-up viewing.

  1. Remove the Dust Cap (B) from the camera (A) and attach the focusable lens (D).
  2. Attach the Macro Tube (H) onto the lens.
  3. Place this assembly over the item you wish to view and ensure there is adequate lighting. If necessary, a desk lamp is a good solution.
  4. Connect the USB power supply to the camera. When the light on the camera is on, it means the camera is working and transmitting images, and you can connect to it through WiFi.
  5. Connect to the Moticam X4 WiFi signal. Please see the instructions on page 11.

Using the Camera on a Trinocular Microscope

Diagram illustrates the Moticam X4 camera (A) with a C-Mount adapter attached, being connected to the trinocular port of a microscope. The C-Ring (C) may be shown as an intermediary part.

  1. Remove the Dust Cap (B) from the camera (A) and attach the microscope's C-Mount adapter. Note: The C-Mount adapter is specific to your microscope. For Motic microscopes, consult the relevant Motic Accessory list and choose an appropriate adapter for your Moticam. Depending on the type of adapter and microscope, the C-Ring (C) may be necessary between the camera and the C-mount adapter.
  2. Connect the USB power supply to the camera. When the light on the camera is on, it means the camera is working and transmitting images, and you can connect to it through WiFi.
  3. Connect to the Moticam X4 WiFi signal. Please see the instructions on page 11.

Connecting and Using with Devices

Connecting to the Moticam X4 WiFi Signal

  1. Each Moticam X4 transmits its own WiFi signal to which you can directly connect your WiFi Device.
  2. The Moticam X's SSID signal name is printed on a label on the camera. To log into your camera, simply connect your WiFi device to that signal. The password for the network by default is 12345678.

Using with Android or iOS Devices

For best performance, it is recommended to use WiFi devices, such as tablets, with a screen not smaller than 7 inches. For iOS devices, use iOS 5 or higher. For Android devices, use Version 4.0 or higher.

  1. To operate and use the camera on your tablet, download the free App called MotiConnect. For iPad, find it on the AppStore. For Android devices, find it on Google Play.
  2. You can also use certain web browsers such as Chrome, Firefox, or Safari to view, measure, and capture without the need for the App. To view the camera stream on your browser, type in the IP number shown on the camera's label (e.g., 192.168.1.151). In your browser, type 192.168.1.151:8080 to connect directly to the camera.
  3. The camera supports both MJPG and H.264 output. By default, the camera is set to H.264 for fast FPS transmission to the MotiConnect App. To view the live image on both MotiConnect and a Web browser, change the output mode to MJPG in the MotiConnect App settings.

Using with a WiFi-Enabled Computer

The Moticam X4 can also be used with the Motic Images Plus software for computers. If you have a WiFi-enabled laptop, go to www.motic.com and download the Motic Images Plus 3.0ML software by registering as a user with the DM serial number found on the box.

To view the camera in the product's MI Devices interface:

  1. Connect your computer to the Moticam X's WiFi signal.
  2. Enter the password.
  3. Open the MI Devices interface by clicking the camera icon within Motic Images Plus.
  4. Select Moticam X4 from the drop-down menu and click Open.

Regulatory Compliance

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.

If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

The device has been evaluated to meet general RF exposure requirements and can be used in portable exposure conditions without restriction.

Models: X4, 2AF2V-X4, 2AF2VX4, Moticam A5 1-2.8 Inch Digital Camera, Moticam A5, 1-2.8 Inch Digital Camera, Digital Camera, Camera

File Info : application/pdf, 17 Pages, 808.38KB

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=5791179

References

Adobe Acrobat Pro DC 15.7.20033 Adobe Acrobat Pro DC 15.7.20033

Related Documents

Preview Moticam BTW Microscope Tablet/Camera Use and Care Manual
Comprehensive guide for setting up, connecting, and using the Moticam BTW microscope tablet and camera system, including software installation, WiFi connectivity, and calibration procedures.
Preview Motic BA210 & BA310 Digital Microscope: Configuration, Operation, and Calibration Guide
Comprehensive guide for Motic BA210 and BA310 Digital Microscopes, covering setup, software installation, operation, image adjustment, and calibration procedures.
Preview Motic SM7 Microscopes for Flat Panel Quality Control
Explore how Motic SM7 optical microscopes enhance quality control in flat panel electronics manufacturing. This guide details common defects, inspection techniques, and the advanced features of the Motic SM7 series.
Preview Motic BA210LED Digital Microscope Instruction Manual
Instruction manual for the Motic BA210LED Digital Microscope, covering setup, usage, troubleshooting, and maintenance.
Preview Motic PX43 BIO & FS6 Series: Intelligent Inverted Microscope for Live Cell Imaging
Explore the Motic PX43 BIO & FS6 Series, advanced inverted microscopes for live cell imaging. Discover features like CCIS optics, ergonomic design, versatile illumination, and high-quality observation modes (Bright Field, Phase Contrast, Fluorescence).
Preview Motic PA53 BIO Series: A Practical Guide to Modern Microscopy
Discover the Motic PA53 BIO Series, an advanced upright biological microscope designed for clinical, research, and teaching labs. This guide details its features, applications, configurations, and technical specifications for enhanced microscopy workflows.
Preview Additive Manufacturing Inspection Applications and Light Microscopy Techniques with Motic SM7 Series
Explore how Motic's SM7 Series microscopes and Moticam cameras are used for inspection and analysis in Additive Manufacturing (3D Printing), focusing on Powder Bed Fusion processes. Learn about powder material analysis, process analysis, defect detection, and surface analysis.
Preview Battery Analysis with Light Microscopy: Motic SM7 Series Guide
This document details how Motic's SM7 series stereo microscopes are utilized for comprehensive battery analysis, covering essential components like electrodes, electrolytes, and separators, and highlighting key inspection parameters for quality control and research.