AcuRite Weather Thermometer

Instruction Manual

Models: 00754/00771W/00772W/00773W/00774W

Contents

Questions? Contact Customer Support at (877) 221-1252 or visit www.AcuRite.com.

SAVE THIS MANUAL FOR FUTURE REFERENCE.

Unpacking Instructions

Remove the protective film that is applied to the LCD screen prior to using this product. Locate the tab and peel off to remove.

Package Contents

  1. Display unit
  2. Outdoor sensor
  3. Instruction Manual

IMPORTANT PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE

Register online to receive 1 year warranty protection www.AcuRite.com

Features & Benefits - Outdoor Sensor

1. Integrated Hanger: For easy placement.

2. Wireless Signal Indicator: Flashes when data is being sent to the display unit.

3. Battery Compartment

4. A-B-C Switch: ID code that must match display's A-B-C switch to ensure units synchronize.

5. Battery Compartment Cover

Features & Benefits - Display Unit

  1. Current Outdoor Temperature: Arrow icon indicates the direction the temperature is trending.
  2. Outdoor Sensor Signal Strength
  3. Daylight Saving Time Indicator: Shown only during setup.
  4. Display Low Battery Indicator
  5. Day of the Week
  6. Current Indoor Temperature: Arrow icon indicates the direction the temperature is trending.
  7. "▼" Button
  8. "SET" Button
  9. "▲" Button
  10. Date
  11. Selected Time Zone
  12. Intelli-Time® Clock
  13. Outdoor Sensor Low Battery Indicator
  14. Freeze Alert Indicator: Indicates temperature is below freezing (32°F; 0°C).
  15. Integrated Hang Hole: For easy wall mounting.
  16. Reset: Full reset to factory default.
  17. A-B-C Switch: ID code that must match sensor's A-B-C switch to ensure units synchronize.
  18. Battery Compartment
  19. Battery Compartment Cover (Not shown)

Setup - Sensor Setup

1. Set the A-B-C Switch

The A-B-C switch is located inside the battery compartment. It can be set to A, B or C. You must select the same letter choices for both the sensor and the display unit in order for the units to synchronize.

2. Install or Replace Batteries

AcuRite recommends high quality alkaline or lithium batteries for the best product performance. Heavy duty or rechargeable batteries are not recommended. The sensor requires lithium batteries in low temperature conditions. Cold temperatures can cause alkaline batteries to function improperly. Use lithium batteries in the sensor for temperatures below -4°F / -20°C.

  1. Slide off the battery compartment cover. Take note of the A-B-C switch setting inside the battery compartment.
  2. Insert 2 x AA batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery compartment.
  3. Replace the battery cover.

Lithium Batteries: 4 F 4 C (70°C) 158°F

Alkaline Batteries: 4 F 2 C (70°C) 158°F

Setup - Display Unit Setup

1. Set the A-B-C Switch

Locate the A-B-C switch inside the battery compartment. Set the A-B-C switch to A, B or C. You must select the same letter choices for both the display unit and the sensor in order for the units to synchronize.

2. Install or Replace Batteries

  1. Remove the battery compartment cover.
  2. Insert 3 x AA alkaline batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery compartment.
  3. Replace the battery cover.

BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment which is not to be used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in fire, as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries (alkaline/standard). DO NOT use rechargeable batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit the supply terminals.

PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.

Intelli-Time® Clock

Intelli-Time products are pre-programmed with the correct time and date. All you need to do is select your Time Zone and Daylight Saving Time preferences. The clock will then automatically update for Daylight Saving Time.

Set the Time, Date & Units

Press the "SET" button, for 3 seconds, to enter SET MODE. Once in set mode, the preference you are currently setting will blink on the display.

To adjust the currently selected (flashing) item, press and release the "▼" or "▲" buttons (press and HOLD to fast adjust).

To save your adjustments, press and release the "SET" button again to adjust the next preference. The preference set order is as follows:

* If you live in an area that observes Daylight Savings Time, DST should be set to ON, even if it is not currently Daylight Savings Time.

You will automatically exit SET MODE if no buttons are pressed for 30 seconds. Enter setup mode at any time by pressing the "SET" button.

Placement for Maximum Accuracy

AcuRite sensors are sensitive to surrounding environmental conditions. Proper placement of both the display unit and outdoor sensor are critical to the accuracy and performance of this product.

Display Unit Placement

Place the display unit in a dry area free of dirt and dust. Display unit stands upright for tabletop use or is wall-mountable.

Outdoor Sensor Placement

Sensor must be placed outside to observe outdoor conditions. Sensor is water resistant and is designed for general outdoor use, however, to extend its life place the sensor in an area protected from direct weather elements.

Hang the sensor using the integrated hang holes or hanger, or by using string (not included) to hang it from a suitable location, like a well covered tree branch. The best location is 4 to 8 feet above the ground with permanent shade and plenty of fresh air to circulate around the sensor.

Important Placement Guidelines

Setup is Complete

The sensor will now synchronize with the display unit. It may take a few minutes for synchronization to complete. Please refer to the troubleshooting section of this manual if anything appears to be functioning improperly.

Operation - Using the Thermometer

High/Low Records

Today's high and low values are recorded for indoor and outdoor temperature. The high and low records automatically clear at 12:00am.

To view the LOW temperature record, press and release the "▼" button. The "MIN" icon appears on the display next to the low records. To view the HIGH temperature record, press and release the "▲" button. The "MAX" icon appears on the display next to the high records.

To reset the LOW records, press AND HOLD the "▼" button while viewing the low records. Dashes will display to confirm all low values have been cleared.

To reset the HIGH records, press AND HOLD the "▲" button while viewing the high records. Dashes will display to confirm all high values have been cleared.

Troubleshooting

No outdoor sensor reception

If the wireless signal indicator shows no bars:

Display screen not working

Outdoor temperature is flashing or showing dashes

Flashing of the outdoor temperature is generally an indication of wireless interference.

  1. Bring both the sensor and display unit indoors and remove at least one battery from each.
  2. Make sure the A-B-C switch on both units match.
  3. Reinstall the battery in the outdoor sensor.
  4. Reinstall the battery in the display unit.
  5. Let the units sit within a couple feet of each other for about 20 minutes to gain a strong connection.

Inaccurate temperature

The unit lost power or batteries were changed and the time is not correct

The Intelli-Time battery needs to be replaced (see page 10). Once the new battery is installed, time and date will need to be set manually.

If your AcuRite product does not operate properly after trying the troubleshooting steps, visit www.AcuRite.com or call (877) 221-1252 for assistance.

Care & Maintenance

Display Unit Care

Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep away from dust, dirt and moisture. Clean ventilation ports regularly with a gentle puff of air.

Outdoor Sensor Care

Clean with a soft damp cloth. Do not use caustic cleaners or abrasives.

Replace Intelli-Time Battery

Intelli-Time technology is powered by a pre-installed coin-cell battery that stores the time and date settings. The battery has a shelf life of several years. To replace the Intelli-Time battery:

  1. Locate the coin cell battery compartment door on the back of the display unit. Unscrew and remove the compartment cover.
  2. Insert 1 x CR2032 coin cell battery into the battery compartment, as shown. Install battery with "+" positive terminal facing OUT.
  3. Screw in the battery cover.

Specifications

Feature Details
TEMPERATURE RANGE Outdoor: -40°F to 158°F; -40°C to 70°C
Indoor: 32°F to 122°F; 0°C to 50°C
WIRELESS RANGE 330 ft / 100 m depending on home construction materials
OPERATING FREQUENCY 433 MHz
POWER Display: 3 x AA alkaline batteries
Sensor: 2 x AA alkaline or lithium batteries
DATA REPORTING Outdoor Data: 16 second updates
Indoor Data: 60 second updates

FCC Information

This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:

  1. This device may NOT cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user authority to operate the equipment.

Customer Support

AcuRite customer support is committed to providing you with best-in-class service. For assistance, please have the model number of this product available and contact us in any of the following ways:

Phone: (877) 221-1252

Email: info@chaney-inst.com

24/7 support at www.AcuRite.com

Limited One Year Warranty

At AcuRite, we proudly uphold our commitment to quality technology. Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship, and to be free of defects when properly installed and operated for a period of one year from the date of purchase.

We recommend that you visit us at www.AcuRite.com for the fastest way to register your product. However, product registration does not eliminate the need to retain your original proof of purchase in order to obtain warranty benefits.

Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship, and to be free of defects when properly installed and operated for a period of one year from the date of purchase. Remedy for breach of this warranty is limited to repair or replacement of the defective item(s). Any product which, under normal use and service, is proven to breach the warranty contained herein within ONE YEAR from date of sale will, upon examination by Chaney, and at its sole option, be repaired or replaced by Chaney. Transportation costs and charges for returned goods shall be paid for by the purchaser. Chaney hereby disclaims all responsibility for such transportation costs and charges. This warranty will not be breached, and Chaney will give no credit for products it manufactures which have received normal wear and tear, been damaged (including by acts of nature), tampered, abused, improperly installed, damaged in shipping, or repaired or altered by others than authorized representatives of Chaney.

The above-described warranty is expressly in lieu of all other warranties, express or implied, and all other warranties are hereby expressly disclaimed, including without limitation the implied warranty of merchantability and the implied warranty of fitness for a particular purpose. Chaney expressly disclaims all liability for special, consequential or incidental damages, whether arising in tort or by contract from any breach of this warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Chaney further disclaims all liability from personal injury relating to its products to the extent permitted by law. By acceptance of any of Chaney's products, the purchaser assumes all liability for the consequences arising from their use or misuse. No person, firm or corporation is authorized to assume for Chaney any other liability in connection with the sale of its products. Furthermore, no person, firm or corporation is authorized to modify or waive the terms of this paragraph, and the preceding paragraph, unless done in writing and signed by a duly authorized agent of Chaney. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

For in-warranty claims: Chaney Instrument Co. 965 Wells St., Lake Geneva, WI 53147

Other AcuRite Products

It's more than accurate, it's ACU RITE.

AcuRite offers an extensive assortment of precision instruments, designed to provide you with information you can depend on to Plan your day with confidence™.

www.AcuRite.com

Printed in China 00754 INST 051614

©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copyrights are the property of their respective owners. AcuRite uses patented technology. Visit www.AcuRite.com/patents for details.

Models: Weather Thermometer, 00754, 00771W, 00772W, 00773W, 00774W

File Info : application/pdf, 12 Pages, 1.11MB

PDF preview unavailable. Download the PDF instead.

00754-instructions

References

Adobe Acrobat Pro DC 20 Paper Capture Plug-in

Related Documents

Preview AcuRite 00754 Weather Thermometer Instruction Manual
Comprehensive instruction manual for the AcuRite 00754 Weather Thermometer, covering setup, operation, troubleshooting, care, specifications, and warranty information.
Preview AcuRite 00384 Thermometer: User Manual, Setup, and Operation Guide
Comprehensive user manual for the AcuRite 00384 indoor/outdoor thermometer. Includes setup instructions, features, operation, troubleshooting, specifications, and warranty information.
Preview AcuRite 00609SBLA1 Digital Thermometer Instruction Manual
Comprehensive guide for the AcuRite 00609SBLA1 Digital Thermometer, covering setup, operation, troubleshooting, and specifications. Learn how to use your indoor/outdoor temperature and humidity monitor.
Preview AcuRite 00826 Thermometer Instruction Manual: Setup, Features, and Troubleshooting
Comprehensive guide for the AcuRite 00826 thermometer. Covers setup, features, placement, operation, troubleshooting, specifications, care, and warranty information.
Preview AcuRite Thermometer Model 00384 Instruction Manual
Instruction manual for the AcuRite Thermometer Model 00384, covering setup, operation, care, and troubleshooting.
Preview AcuRite 01535 High Resolution Weather Station Instruction Manual
Instruction manual for the AcuRite 01535 High Resolution Weather Station, covering unpacking, setup, features, operation, troubleshooting, and specifications. Includes details on the 5-in-1 sensor and display.
Preview AcuRite 00526W Thermometer Instruction Manual
Instruction manual for the AcuRite 00526W thermometer with wireless outdoor sensor. Includes setup, usage, troubleshooting, and specifications.
Preview AcuRite 00891A Thermometer with Probe Instruction Manual
Comprehensive instruction manual for the AcuRite 00891A Thermometer with Probe, detailing setup, operation, features, troubleshooting, specifications, and warranty information provided by Chaney Instrument Co.