AIKE AK2630 Air Hand Dryer
User Manual
Install Method
- Connect the line: When installing the unit without a terminal box, install it above the right side of the unit with a two-hole standard outlet. The distance should be 20-50cm.
- Power supply line: Please embed the terminal box without a cover in the installation location when directly connecting the power cord is needed. Otherwise, the power cord will be forced out of the body and cannot be properly installed. The unit provides a long power cord; please cut off the extra power cord as needed. Pull out the power cord and connect it with the unit's power cord. Wire connection must be based on the principle that the live wire connects with the brown wire, the null line connects with the blue line, and individually wrap with insulation tape to ensure no leakage.
- Fix the mounting plate: Fix the mounting plate on the wall with screws according to the size. The mounting plate dimensions are approximately 135mm x 1060mm, with screw holes at 102.5mm and 1170mm intervals.
- Installation of unit: Visually orient the unit and hang it on the mounting plate.
- Fix the unit: Press on the unit slightly. Then pull out the filter box, aiming at the hole of the insurance screw, use a cross screwdriver to turn in one screw at an angle of 45 degrees until the unit is fixed firmly.
Test Run
- Shake the unit gently: Confirm the power and voltage.
- Switch on the power: Close the external power supply switch or insert the power plugs.
- Slid in your hands to drying: High-speed wind blows out.
Check & Notice
- Firm Installation: The unit is installed firmly without shaking. It will occur shaking and noisy when the unit doesn't install firmly.
- Power Supply: Please use the rated power supply. It will burn out the unit or cause human accidents if the power is used incorrectly. Power socket must match the unit plug. Please check the power when the indicator light is not bright.
- Sensor Check: Please confirm whether your hands are far away from the sensor parts if there is no wind blowing out.
Daily Use and Maintenance
External maintenance
- Wipe with a soft dry cloth or towel. Please use neutral detergent.
- Please do not use organic solvents, acid or alkali toilet cleaner, cleaning brush, etc. Otherwise, the unit's surface finish will be destroyed or discoloration will occur. If using a chemical cloth, make sure to follow its usage instructions.
Air Filter Maintenance
- Remove the air filter box: Hold the raised part and pull down to easily remove it.
- Remove the air filter: Remove the air filter from the box.
- Clean the air filter: Blow or brush off the dust from the air filter. Change it when the dust is too much or after over 3 years of use. Prohibit washing: Washing will damage the antibacterial components.
Hand Drying
- Slowly moving up the back of the hand before and after.
- Palm of the hand before and after slowly moving upwards.
- Mutual hands.
Specifications
Item | Details |
Motor Type | Brush Motor |
Sensing Distance | 15-20cm |
Waterproof | IP24 |
Dimensions | 250x165x245mm |
N.W | 3.0kg |
Rated Voltage | AC100-130V |
Phase | Single-phase |
Input Power | 1400-1650W |
Air Speed | 105m/s |
Heating Power | 800-950W |
WARNING
- Children: Do not let children hang on the unit. Otherwise, there is a risk of falling.
- Front Panel: Do not open the front panel. Otherwise, it may cause an electric shock risk.
- Water Splashing: Do not splash water. Otherwise, it may cause an electric shock risk. Prohibit use in bathrooms and showers. Do not use in places where water is directly splashed or where it is prone to freezing. Otherwise, this may cause electric shock and unit malfunction.
- Disassembly: Please follow instructions. Prohibit unnecessary disassembling. Otherwise, it may cause fire, electric shock, and injury accidents.
- Power Supply: Rated power is required. If the power tolerance is over +/-10%, there will be breakdown. If using incorrect power supply, fire, electric shock, and unit malfunction will happen. Please use a dedicated socket. If used in combination with other appliances, it may cause abnormal heat in the shunt outlet.
- Maintenance: Power must be turned off during maintenance to prevent the risk of electric shock.
- Air Filter: Air filter must be installed.
- Malfunction: If the unit doesn't work or has abnormal conditions, please turn off the power to prevent accidents; close the leakage circuit breaker and ask the supplier to check and repair, or it may lead to fire because of electricity leakage and short circuit.
- Ground Connection: Unit must have reliable ground connection.
- Installation Safety: Attention when installing: Do not install when the unit is powered on.
- User Capability: This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Damaged Cord: If the cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard.
- RCD Protection: For additional protection, the installation of a residual current device (RCD) having a rated residual operating current not exceeding 30mA is advisable in the electrical circuit supplying the bathroom. Ask your installer for advice.
- Child Use: This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Precautions before Installation
Unsuitable Locations
Do not install in the following places (Otherwise may cause malfunction):
- Places with temperatures below -10 °C or over 40 °C.
- Places directly sprinkled by water.
- Places with direct sunlight or strong light.
- Places prone to condensation.
- Places filled with corrosive, oxidizing, and reducing gas.
- Places with altitude over the range of 0~2000m.
Installation Location
The following picture shows the recommended location. (If there is a floor or obstacles below the unit, the distance between the unit and the floor or obstacles should be at least 400mm.)
- Keep the right side of the unit away from mirrors or walls, as water droplets may splash out when drying hands. (The distance should be 100mm above.)
- Please avoid places that are easily encountered by people and easy to encounter doors.
- Please select a flat wall to install this product.
Electrical Diagram
The diagram shows the electrical connections including the power line, fuse, indicator, outlet, sensing device, control relay, temperature probe, sensing probe, MOTOR, temperature switches, and heater.
Environmental Protection
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice.