Rossmax AM30 Bubble Air Mattress User Manual

Model: AM30

Manufacturer: Rossmax Swiss GmbH

Website: www.rossmax.com

Introduction

Thank you for purchasing the Rossmax bubble air mattress. With proper care and use, your air mattress will provide you with many years of reliable treatment. This guide book provides information on setting up and the features of your air mattress. The mattress relieves pressure by sequentially deflating and inflating alternate air cells on approximately 6-minute timed intervals. It is intended to help reduce the incidence of pressure ulcers while optimizing patient comfort and providing long-term care for patients suffering from pressure ulcers.

Attention: Consult the accompanying documents. Please read this manual carefully before use. Keep this manual for future reference.

Product Cautions

How to Use

  1. Place the mattress on the bed frame with the hose end at the foot section of the bed frame. Secure the mattress firmly by fixing the flags to the bed frame if available.
  2. Using the integrated hangers, securely hang the pump on the bed end at the foot end or place it on a smooth, flat surface.
  3. Connect the air hoses from the mattress to the pump unit. Note: Check and ensure the air hoses are not kinked or tucked under the mattress.
  4. Plug the pump into a wall electrical outlet. Ensure the power cord is safely away from possible hazards. Note: After installation, any extra length of power cord should be neatly arranged to avoid tripping accidents.
  5. Turn on the power switch on the control panel of the pump. The pump will begin to inflate the mattress. Note: The pump should only be used with the mattress recommended by the manufacturer. Do not use it for any other purpose.
  6. While inflating, adjust the pressure setting based on patient comfort level by turning the pressure adjustment knob clockwise to increase firmness. Note: It is recommended to set the pressure to maximum first, then adjust to the desired softness after setup is completed.

Clean and Disinfection

  1. Wipe the pump unit with a damp cloth and mild detergent. Choose a detergent that will have no chemical effects on the plastic case of the pump unit.
  2. Wipe down the mattress with warm water containing a mild detergent and air dry thoroughly before use. Note: Do not use phenolic-based products for cleaning. After cleaning, dry the mattress without direct exposure to sunlight.

Troubleshooting

Symptoms Check Point / Correction
Power is not ON • Check if the plug is connected to mains.
• Check for a blown fuse.
Patient is bottoming out (Pressure setting might be inadequate) Adjust to a higher pressure and wait for a few minutes for best comfort.
Mattress form is loose Check if the mattress is fixed to the bed frame by flags.
No air produced from some air outlets of the air tube connector This is normal as it is in alternating mode; air outlets take turns to produce air during their cycle time.

Note: If the pressure level is consistently low, check for any leakage (tubes or air hoses). If necessary, replace any damaged tube or hoses or contact Rossmax service.

Specifications

Pump Unit

Dimension (L x W x H) 26.5 x 13.5 x 10 cm
Weight 3 lbs (1.4 kg)
AC Power Source AC 230V/50Hz or AC 220V/60Hz or AC 110V/60Hz
Cycle Time 6 mins

Mattress

Dimension (L x W x H) 79" x 35" x 3" (200 x 90 x 7 cm)
Extension Flags 20" (50 cm) on both sides
Weight 5 lbs (2.3 kg)
Weight Capacity 220 lbs (100 kg)
Operating Condition 10°C to 40°C (50°F to 104°F), 10% to 75% RH; 700~1060hPa
Storage & Transportation Condition -18°C to 43°C (0°F to 110°F), 10% to 95% RH
Applied Parts Type BF
IP Classification IP21: Protection against harmful ingress of water and particulate matter

Parts Identification

The pump unit features the following parts:

Electromagnetic Compatibility (EMC) Information

This device must be installed and operated according to the user manual. Portable RF communications equipment should be used no closer than 30 cm (12 inches) to any part of the AM30. Specific guidelines and separation distances are provided based on transmitter power and frequency.

Manufacturer's Declaration - Electromagnetic Immunity: The AM30 is intended for use in a specified electromagnetic environment. The user must ensure it is used in such an environment.

Immunity Test Details:

Note: Guidelines may vary based on electromagnetic propagation factors. More information is available on the Rossmax website.

Disposal Information

The symbol on this product indicates it is an electronic product. In accordance with European directive 2012/19/EU, electronic products must be disposed of at a local recycling center for safe treatment.

Warranty Information

This instrument is covered by a 1-year guarantee from the date of purchase. The mattress and accessories are not included in the guarantee. For products sold within the European Union, Rossmax acknowledges all consumer rights granted under EU Directive 2019/771 and respective national laws. The guarantee is valid only upon presentation of the warranty card completed or stamped by the seller/dealer confirming the date of purchase, or the receipt. Opening or altering the instrument invalidates the guarantee. The guarantee does not cover damage, accidents, or non-compliance with the instruction manual.

Please contact your local seller/dealer, buying source, or visit www.rossmax.com.

Customer Information:

Customer Name: ______________________________________________________________________

Address: _____________________________________________________________________________

Telephone: ___________________________________________________________________________

E-mail address: ________________________________________________________________________

Product Information:

Date of purchase: _____________________________________________________________________

Store where purchased: ______________________________________________________________________________________

Models: AM30 Air Mattress Bubble Type, AM30, Air Mattress Bubble Type, Air Mattress, Mattress

File Info : application/pdf, 2 Pages, 662.46KB

PDF preview unavailable. Download the PDF instead.

OBM IB AM30 V9 SW

References

Adobe InDesign CS5 (7.0.4) Adobe PDF Library 9.9

Related Documents

Preview Rossmax Aspirator V3 Instruction Manual - Safe and Effective Suction Therapy
Comprehensive instruction manual for the Rossmax Aspirator V3 medical suction unit. Learn about intended use, safety precautions, setup, operation, cleaning, and troubleshooting for effective suction therapy.
Preview Rossmax HS200 Blood Glucose Monitoring System User Manual
Comprehensive guide to the Rossmax HS200 Blood Glucose Monitoring System, covering setup, testing, troubleshooting, specifications, and safety for accurate blood glucose management. Visit www.rossmax.com for more information.
Preview Rossmax CH155 Automatic Blood Pressure Monitor | Accurate Home Health
Discover the Rossmax CH155 Automatic Blood Pressure Monitor, designed for accurate and convenient home health monitoring. Features include Movement Detection, Real Fuzzy Technology, Hypertension Risk Indication, Irregular Heartbeat Detection, and clinically validated accuracy by ESH and BIHS.
Preview Rossmax CF155f Blood Pressure Monitor User Manual
Official user manual for the Rossmax CF155f digital blood pressure monitor. Provides detailed instructions on setup, operation, measurement procedures, troubleshooting, and technical specifications for accurate home health monitoring.
Preview Rossmax NA100 Piston Nebulizer: Instruction Manual & User Guide
Comprehensive instruction manual for the Rossmax NA100 Piston Nebulizer. Learn how to operate, clean, assemble, and troubleshoot your device for effective respiratory therapy.
Preview Rossmax Z1 Automatic Blood Pressure Monitor User Manual
This document provides instructions for using the Rossmax Z1 Automatic Blood Pressure Monitor, including setup, operation, troubleshooting, and technical specifications. It covers features like Real Fuzzy Technology, Cuff Wrap Detection, Movement Detection, Hypertension Risk Indication, and Irregular Heartbeat Detection.
Preview Rossmax Z5 Automatic Bluetooth Blood Pressure Monitor - User Manual & Features
Comprehensive user manual for the Rossmax Z5 Automatic Bluetooth Blood Pressure Monitor, detailing features like PARR technology, AFib detection, Bluetooth connectivity, measurement procedures, troubleshooting, and specifications.
Preview Rossmax NE100 Compressor Nebulizer User Manual
Comprehensive user manual for the Rossmax NE100 Compressor Nebulizer, covering setup, operation, cleaning, maintenance, troubleshooting, and specifications.