Features
- Meets IEC 62368-1 & IEC 60950-1
- Meets Energy Efficiency DOE Level VI
- Meets Code of Conduct Version 5 Tier 2
- High Reliability
- EMC Standard: EN55032/ EN55024 Class B
- Over Current Protection
- Over Temperature Protection
- Over Voltage Protection
Safety Standard Approval
- CULUS LISTED I.T.E. POWER SUPPLY E190414
- TÜV Rheinland ZERTIFIZIERT (ID 1000000000)
- Tested to Comply With FCC Standards
- FOR HOME OR OFFICE USE
Image of a compact, black AC to DC power adapter with a standard AC input connector.
Description
This product is a 30~50 watt AC to DC adapter intended for use in Consumer Electronic Systems that have small wattage demands. This adapter operates at 90 to 264 VAC input voltage. The unit meets CISPR32 EN55032 CLASS B, EN55024 and FCC PART 15B Class B emission limits, and is designed for ITE application.
Input Specifications
- Input voltage: 90-264 VAC
- Input frequency: 47-63 Hz
- Input current: ≤ 1.2A (100Vac, 240Vac / full load)
- No load power consumption: ≤ 0.075W (115Vac, 230Vac)
- Touch current: ≤ 0.25mA (264Vac / 50Hz)
Output Specifications
- Output voltage/current: See rating chart
- Total output power: See rating chart
Protection Features
- Over voltage: The adapter will enter into shut down (no output) if over voltage occurs at the output terminal due to an internal fault. The output trip voltage shall not exceed 63 Vdc. Normal state is restored by AC reset.
- Short circuit & Over current: When an internal or external fault is applied to the output, the power supply shall shut down and enter auto-recovery mode.
- Over temperature: The power supply will enter into shut down when abnormal thermal rise occurs. Normal state is restored by AC reset.
- Brown-out: Set at 50Vac~60Vac
Environmental Specifications
- Working TEMP.: 0~70°C (de-rating > 40°C)
- Storage TEMP.: -20~+80°C
- Working Humidity: 20~80% RH non-condensing
- Storage Humidity: 10~90% RH non-condensing
Input Specifications (Performance)
- Efficiency: See rating chart.
- Power turn-on time: ≤ 3 Sec (At 100Vac / full load, output voltage shall remain regulation)
- Hold-up time: ≥ 8ms (At 100Vac or 240Vac / full load, output voltage shall remain regulation)
- Inrush current: Shall be less than the rating of adapter critical component (including rectifiers, fuse surge and current limiting device) at 100Vac, 240Vac / full load.
- Operating altitude: 5000 meters above sea level
- Withstand voltage: Between AC input and secondary applied DC 4242V, test time 1 minute, cut off current shall be less than 10mA.
- MTBF: 300,000 hours at 25°C, 100Vac, 240Vac / full load (standard SR332)
EMC Performance
- EN55032: Class B conducted, Class B radiated
- FCC: Class B conducted, Class B radiated
- VCCI: Class B conducted, Class B radiated
- EN61000-3-2: Meets class D
- EN61000-3-3: Meets regulation
- EN61000-4-2: Air discharge: ±8 KV, contact discharge: ±4KV, meets criterion A
- EN61000-4-3: 80~1000 MHz, 3V/m, 80% AM(1kHz), meets criterion A
- EN61000-4-4: Impulse: ±1kV applied to L,N, meets criterion A
- EN61000-4-5: ±1kV applied differential mode, ±2kV applied common mode, meets criterion A
- EN61000-4-6: 0.15~80 MHz, 3Vrms, 80% AM(1kHz), meets criterion A
- EN61000-4-8: 50 Hz or 60Hz, 1A/m, meets criterion A
- EN61000-4-11 Voltage Dips: >95% reduction for 0.5 period, meets criterion B; 30% reduction for 25 period, meets criterion C
- Voltage Interruptions: >95% reduction for 250 period, meets criterion C
Power De-rating
For 100Vac or 240Vac input, de-rating applies as follows: 0°C to 40°C at 100% load, 50°C at 85% load, 60°C at 70% load, 70°C at 55% load. (Shall be less than the rating of adapter critical component, follow FSP specification (adapter)).
Performance Curves
Input Voltage Derating Curve
A line graph showing Input Voltage Derating Curve, with Input Voltage (Vac) on the x-axis (ranging from 90 to 264) and % Output Power on the y-axis (ranging from 0 to 100). The curve shows output power decreasing as input voltage increases beyond a certain point.
Output Power Derating Curve
A line graph showing Output Power Derating Curve, with Temperature (°C) on the x-axis (ranging from 0 to 70) and % Max Load on the y-axis (ranging from 0 to 100). The curve shows output power decreasing as temperature increases above 40°C.
Output Voltage/Current Rating Chart
Model | Output Voltage | Output Current | AC Inlet | Efficiency DOE(Level VI) | Efficiency CoC V5 (Tier 2) |
---|---|---|---|---|---|
FSP030-DFAN3 | 48V | 0.625A | C14 | ≥86.95% | ≥87.70% |
FSP030-DWAN3 | 54V | 0.56A | C14 | ≥86.95% | ≥87.70% |
FSP040-DFAN3 | 48V | 0.83A | C14 | ≥87.59% | ≥88.59% |
FSP040-DWAN3 | 54V | 0.74A | C14 | ≥87.59% | ≥88.59% |
FSP050-DFAN3 | 48V | 1.042A | C14 | ≥88% | ≥89.0% |
FSP050-DWAN3 | 54V | 0.93A | C14 | ≥88.0% | ≥88.59% |
Mechanical Specifications
The main adapter unit has approximate dimensions of 97mm x 50mm x 30mm. It features a black case with a label indicating model and specifications. A cable tie made of PET plated material secures the output cable. The output cable is approximately 1200mm ± 20mm long and uses wire gauge 22AWG. Ferrite components are included as required.
Connector Specifications
The AC input connector is a standard C14 type. The DC output connector is shown with two terminals labeled 'a' (black print white) and 'b' (print edge). The wiring for the output cable uses wire number 2468 with a 22AWG gauge.