FSP 50W ~ 65W 12V Adapter
FSP050(60/65)-DHAN3 Series
Features
- Meets IEC 62368-1 & IEC 60950-1
- Meets Energy Efficiency DOE Level VI
- Meets Code of Conduct Version 5 Tier 2
- High Reliability
- EMC Standard: EN55032/ EN55024 Class B
- Over Current Protection
- Over Temperature Protection
- Over Voltage Protection
Safety Standard Approval
Safety standard approval logos are present, indicating compliance with various international standards including CULUS, TÜV Rheinland, CE, FCC, and others. The product is tested to comply with FCC Standards for home or office use.
Description
This product is a 50~65 watt AC to DC adapter designed for use in IPC systems, embedded systems, printers, monitors, and POS systems that have high wattage demands. It operates at 90 to 264 VAC input voltage and meets CISPR32 EN55032 CLASS B, EN55024, and FCC PART 15B Class B emission limits. It is designed for ITE (Information Technology Equipment) applications.
Input Specifications
Parameter | Value |
---|---|
Input voltage | 90-264 VAC |
Input frequency | 47-63 Hz |
Input current | ≤ 1.0A (100Vac, 240Vac / full load) |
No load power consumption | ≤ 0.075W (115Vac, 230Vac) |
Touch current | ≤ 0.25mA (264Vac / 50Hz) |
Output Specifications
Output voltage/current and total output power are detailed in the "Output Voltage/Current Rating Chart".
Protection Features
- Over voltage: The adapter enters shutdown mode if overvoltage occurs at the output terminal due to internal fault. The output trip voltage will not exceed 28V. Normal state is restored by AC reset.
- Short circuit & Over current: In case of internal or external fault applied to the output, the power supply shuts down and enters auto-recovery mode.
- Over temperature: The power supply enters shutdown mode if abnormal thermal rise occurs. Normal state is restored by AC reset.
- Brown-out: Shutdown without damage.
Environment
Condition | Value |
---|---|
Working Temperature | 0~70°C (derating required above 40°C) |
Storage Temperature | -20~+80°C |
Working Humidity | 20~80% RH non-condensing |
Storage Humidity | 10~90% RH non-condensing |
Performance Specifications
Parameter | Value |
---|---|
Power factor | N/A |
Efficiency | See rating chart |
Power turn-on time | ≤ 3 Sec (at 100Vac / full load, output voltage shall remain regulation) |
Hold-up time | ≥ 10ms (at 100Vac or 240Vac / full load, output voltage shall remain regulation) |
Inrush current | Shall be less than the rating of adapter critical component (including rectifiers, fuse, surge and current limiting device) at 100Vac, 240Vac / full load. |
Operating altitude | 5000 meters above sea level |
Withstand voltage | Between AC input and secondary applied DC 4242V, test time 1 minute, cut off current ≤ 10mA |
MTBF | ≥ 300,000 hours (at 100Vac, 240Vac / full load, 25°C, standard SR332) |
EMC Performance
Standard | Compliance |
---|---|
EN55032 | Class B conducted, Class B radiated |
FCC | Class B conducted, Class B radiated |
VCCI | Class B conducted, Class B radiated |
EN61000-3-2 | Meet class A |
EN61000-3-3 | Meet regulation |
EN61000-4-2 | Air discharge: ±8 KV, contact discharge: ±4KV, meet criterion A |
EN61000-4-3 | 80~1000 MHz, 3V/m, 80% AM(1kHz), meet criterion A |
EN61000-4-4 | Impulse: ±1kV applied to L,N, meet criterion A |
EN61000-4-5 | ±1kV applied differential mode, ±2kV applied common mode, meet criterion A |
EN61000-4-6 | 0.15~80 MHz, 3Vrms, 80% AM(1kHz), meet criterion A |
EN61000-4-8 | 50 Hz or 60Hz, 1A/m, meet criterion A |
EN61000-4-11 | Voltage Dips: >95% reduction for 0.5 period, meet criterion B; 30% reduction for 25 period, meet criterion C. Voltage Interruptions: >95% reduction for 250 period, meet criterion C. |
Derating Curves
Input Voltage Derating Curve
This graph illustrates the adapter's performance across different input voltages. It shows that the output power remains at 100% of the maximum load across the entire input voltage range from 90 VAC to 264 VAC.
Output Power Derating Curve
This graph shows the adapter's output power capability relative to ambient temperature. The adapter maintains 100% of its maximum load up to approximately 40°C. Beyond 40°C, the output power is derated, decreasing as the temperature rises towards 70°C.
Output Voltage/Current Rating Chart
Model | Output Voltage | Output Current | AC Inlet | Efficiency (DOE Level VI) | Efficiency (CoC V5 Tier 2) |
---|---|---|---|---|---|
FSP050-DHAN3 | 12V | 4.17A | C14 | ≥88% | ≥89% |
FSP060-DHAN3 | 12V | 5A | C14 | ≥88% | ≥89% |
FSP065-DHAN3 | 12V | 5.42A | C14 | ≥88% | ≥89% |
Mechanical Specifications
The adapter unit has approximate dimensions of 100mm (length) x 50mm (width) x 30mm (height), with specific details provided in dimensional drawings. The case color is black.
Connector Specifications
The DC output cable is approximately 1000mm in length, features a 16AWG wire gauge, and is black in color. A ferrite bead is included as required on the cable. The output connector is a standard barrel type, with specific pin configurations and dimensions detailed in the connector drawings.