Scanstrut ROKK Charge Pro SC-USB-03 Installation Instructions
Part List
- Shell (x1)
- Gasket (x1)
- Lock Ring (x1)
- No.6 x 16 Screw (x1)
Tools Required
- Ø2.5mm (3/32") Drill Bit
- Pozi Screwdriver
- Ø29mm (1 1/8") Hole Saw
- Silicone
Installation Steps
Step 1: Mark Hole Centre
Mark hole centre for drilling
[Diagram: Marking the center point for drilling a hole.]
Step 2: Drill Mounting Holes
Drill mounting holes
[Diagram: Illustrates drilling mounting holes. Shows a cross-section of a surface with a hole being drilled. Includes dimensions: 3mm minimum, 25mm maximum depth for the hole. Also shows pilot hole size recommendations based on material: 2.5mm (3/32") for soft material (e.g., plywood) and 3mm (1/8") for hard material (e.g., fiberglass) for a No. 6 screw.]
Step 3: Mount the Unit
Feed SC-USB-03 through the gasket and hole. Tighten lock ring onto product until securely fixed. Screw product into place.
[Diagram: Shows the SC-USB-03 unit being inserted through the gasket and the pre-drilled hole. The lock ring is then shown being tightened onto the unit to secure it.]
Step 4: Connect Power Supply
Connect to 12/24V supply, ensuring a waterproof connection. Fuse and select cable diameter according to input voltage and current for your specific installation.
[Diagram: Depicts the SC-USB-03 unit connected to a 12/24V power source. It emphasizes the need for a waterproof connection and advises selecting appropriate fuse and cable diameter based on installation requirements.]
Technical Information
Specification | Details |
---|---|
Input voltage | 12/24V System (10-32V DC) |
Input current Max | 6 A |
Output Type C (12V System) | 5V 3A, 9V 3A, 12V 3A MAX |
Output Type C (24V System) | 5V 3A, 9V 3A, 12V 3A, 15V 3A, 20V 3A MAX |
Output Type A MAX | 5V 1.5A, 9V 1.5A, 12V 1.5A/3A MAX |
Standby draw | 0.01W |
Waterproof rating | IPX6 |
Certification | CE, FCC, C-Tick, ROHS, UKCA |
Cutting Template
1:1 Scale
[Diagram: A cutting template with dimensions for marking and cutting the mounting hole. Key dimensions include: Ø 29 mm (1 1/8") for the main hole, Ø 2.5 mm (3/32") for a pilot hole, and 43.5 mm (1.7") for a reference measurement. The template also indicates a 50 mm (2") scale reference.]
Print document 1:1 Scale for correct cutting template size.
Important Safety Information
WARNING:
- This product is to be connected to a 12V DC or 24V DC battery power source only. The power supply must be switched off before installation.
- An appropriate fuse or circuit breaker must be used between the battery / power source and this product. Check for correct polarity of all wiring before switching the power on.
- This product may contain high voltages. Do not tamper with the product.
- This product is NOT approved for use in hazardous/flammable atmospheres. Do NOT install in a hazardous/flammable atmosphere e.g. engine room.
- Before drilling any holes, ensure the area behind the mounting location is clear of wires, fuel and all other hazardous objects.
- Ensure any holes cut will not significantly weaken the structure of the mounting surface.
- If the product needs to be mounted outside, it must be mounted in a location safely above the waterline, where it is not at risk of being submerged.
CAUTION:
- This product does not contain any user serviceable parts. DO NOT attempt to repair or modify the product in any way.
- When used in high ambient temperature or in direct sunlight, the product may turn off temporarily, this is a safety feature of the electronics.
- The IP protection rating is only valid if the installation is carried out correctly according to the instructions and on a perfectly flat, smooth and non-porous surface.
- When choosing a mounting location, avoid areas exposed to heat radiation devices and areas with poor ventilation.
WIRING:
- Professional electrician installation recommended, see Technical Information for power requirements.
- To achieve max power output, the specified voltage must be at the charger. Battery performance and voltage drop needs to be considered for installation.
ENVIRONMENTAL PROTECTION:
- Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice.
IMPORTANT:
- Scanstrut Ltd & Inc. accepts no responsibility for any injuries or other damages arising from the use of their products in any circumstances.
WARRANTY:
- A 2 year, non-transferrable warranty covers this Scanstrut product only and not any devices that are charged by it. No warranty is given for users' devices and users expose their devices to hazards, known or unknown, at their own risk.
CE Warning
- Scanstrut Ltd declares the product 'ROKK CHARGE+' SKU: SC-USB-03 is in compliance with EMC CE Directive (2014/30/EC). The CE certificate of conformity can be found at www.scanstrut.com/uk/compliance.
Contact Information
UK & International: +44 (0)1392531280, sales@scanstrut.com
USA: +1 860 308 1416, usasales@scanstrut.com