Bosch D9412GV2 Control Panel: Integrated Security Solution
An overview of the Bosch D9412GV2 Control Panel, a versatile system for intrusion detection, fire alarms, and access control.
Product Overview
The Bosch D9412GV2 Control Panel offers an integrated solution for access control, intrusion, and fire alarm system applications. It allows users to monitor alarm points for intruders or fire alarms while operating user command centers and other outputs.
The panel includes a communicator that sends events to selected public switched telephone network (PSTN) or IP network destinations through four programmable route groups. System functions can be programmed on-site using a D5200 Programmer or remotely via Remote Programming Software (RPS).
The D9412GV2 Control Panel supports up to eight doors of access control when using the optional D9210BLC Access Control Interface Module. It provides up to 246 individually identified points, accommodating normally-open (NO) and normally-closed (NC) devices with end-of-line (EOL) resistor supervision. Points can be programmed for fire, fire supervisory, or intrusion applications.
A photograph shows the Bosch D9412GV2 Control Panel unit alongside several keypads and communication modules, suggesting a comprehensive security system setup.
Key Features
- Fully integrated intrusion, fire, and access control, allowing users to interface with one system instead of three.
- NetCom IP based communication option provides high-speed, secure alarm transport and control.
- Eight programmable areas with perimeter and interior partitioning.
- 246 points with flexible configuration options to meet multiple installation requirements.
- Choice of vacuum fluorescent or ATM style user interface command centers.
- New user interface functions provide additional security and flexibility.
- Supports up to 238 RF points.
Functions
Programmable Outputs
- 2 A alarm power at 12 VDC
- 1.4 A auxiliary power at 12 VDC
- Four alarm output patterns
- Programmable bell test
- Programmable bell shut-off timer
System Response
- 31 custom point indexes, including fire supervisory.
- Selectable point response time.
- Cross point capability.
- Fire alarm verification.
- Fire inspector's local test.
- Watch mode.
- Scheduled events (skeds) can arm, disarm, bypass and unbypass points, control relays, control authority levels, and control door access.
User Interface
- Supervises up to eight command centers (up to 32 unsupervised command centers can be used).
- Supports custom command center text.
- Full function command menu including custom functions.
- Each user has authority by area and a 16-character name.
- 14 custom authority levels control user's authority to change, add, delete passcodes or access control credentials, disarm, bypass points, and start system tests.
- Adjustable brightness or volume for the command center display or sounder.
Note: Use at least one command center in each system.
Area Configurations
Area programming offers a wide selection of different system configurations. Assign an account number to each area to define annunciation, control, and reporting functions. Multiple areas can be linked to an automatically controlled shared area, such as a hallway or lobby. Area arming can be conditional on other areas (master and associate).
Security Features
Two Man Rule
Requires two unique passcodes on the same command center to disarm an area. Without the second passcode, the system denies entry. This feature requires the presence of two people at opening, providing added security.
Early Ambush
Requires two passcode entries on the same command center. The first entry disarms the area, and the second entry stops a timer programmed to send a duress event. If the second entry does not occur within the programmed time, the system generates a duress event. Early Ambush allows users to inspect the premises and use the system to confirm that the area is safe to enter, providing added security.
Easy Exit Control
The D9412GV2 Control Panel allows changing from one armed state to another armed state without disarming. For example, changing from Master Arm to Perimeter Arm. This reduces keystrokes, simplifying system operation.
Programmable Passcode-controlled Menu List
The system prompts users to enter a passcode before viewing the command center menu. The command center display shows the user only the menu options allowed according to their authority level, simplifying system operation.
Passcode Follows Scope
Restricts passcode arming and disarming to the command center's immediate local area, even if the command center can report events from other areas. This simplifies the arming and disarming procedure without limiting other command center capabilities.
Invisible Walk Test
A menu item allows the user to test invisible 24-hour points within the scope of the command center without sending a report to the central station.
Door Activated Custom Function
A custom function activates when user credentials are presented to a D9210B door controller's reader. The custom function mimics a function performed at the command center associated with the door controller.
Passcodes
User passcodes contain three to six digits. Each user can be assigned one of fourteen customized authority levels in each area. Passcodes can be restricted to operate only during certain times. The Two Man Rule and Early Ambush options require two passcodes, providing additional security in environments like banks.
Communications
The D9412GV2 Control Panel prioritizes and sends reports to four route groups, each with a programmable primary and backup destination. It works with the D6600 NetCom Communications System using a DX4020 Network Interface Module, offering programmable anti-replay and anti-substitution features.
The Modem IIIa² Communications Format, available with Bosch receivers, adds reporting capabilities such as:
- Individual point numbers and text.
- Opening or closing reports by area number.
- Remote programming attempts.
- Diagnostic reports.
- Sends user names to the central station.
Security and Fire Detection
The D9412GV2 Control Panel provides eight on-board points and up to 238 additional off-board points (depending on model and expansion interfaces). Individual points can be programmed to monitor all types of burglar alarms, fire alarms, and supervision devices.
Event Log
The event log stores up to 1,000 local and transmitted events, including time, date, event, area, point, and user number. Event logs can be viewed from select command centers or retrieved remotely using RPS. RPS operators can retrieve events periodically via a single phone call. When the event log reaches a programmed threshold, it can send an optional report to a receiver.
Access Control Details
The D9412GV2 provides custom door strike, point shunt, and auto disarming response by area. It features 14 panel-wide access levels with both manual and scheduled control. Access events can be stored, viewed, or printed, including:
- Access granted
- No entry
- Request-to-enter
- Request-to-exit
Scheduled Events (Skeds)
The internal clock and calendar start individually scheduled events (skeds). Skeds perform functions such as arming or disarming, relay control, or point bypassing. The D9412GV2 Control Panel offers:
- 40 scheduled events with up to 25 different functions.
- Eight opening windows and eight closing windows.
- Eight user windows.
- Day-of-week, date-of-month, or holiday only schedules.
- Four holiday schedules of 366 days each (leap year).
Fire Test
When a user activates Fire Test Mode, the control panel suppresses all reports to the central station. The command center and annunciator display all testing data. An automatic sensor reset feature saves time, eliminating the need to manually reset sensors. At the end of the test, the command center shows the number of untested points.
Programming, Diagnostics, and Controls
Users can program on-site with a D5200 Programmer or remotely through RPS. A programmable system passcode prevents unauthorized remote programming. D9412GV2 Control Panels accommodate up to four separate telephone numbers for primary, alternate, and backup receivers for automatic test reports. When resetting alarms or arming/disarming a system, the user is identified by name and number.
Parts Included
D9412GV2 Components | Quantity |
---|---|
D9412GV2 Board | 1 |
Mounting Skirt | 1 |
Faceplate with D9412GV2 Label | 1 |
Certifications and Approvals
Note: The D9412GV2 Control Panel is designed to comply with the following certifications, standards, and approvals.
UL Standards
- UL365, Police Station Burglar Alarm Units and Systems
- UL464, Audible Signal Appliances
- UL609, Local Burglar Alarm Units and Systems
- UL864, Control Units for Fire-protective Signaling Systems
- UL985, Household Fire Warning System Units
- UL1023, Household Burglar-alarm System Units
- UL1076, Proprietary Burglar Alarm Units and Systems
- UL1610, Central-station Burglar-alarm Units
- UL1635, Digital Alarm Communicator System Units
Approvals
FCC: AJ9MLU-46532-AL-E
Compatible Products
Command Centers
- D1260 Series Command Centers (D1260, D1260W, D1260R, D1260BLK, D1260B)
- D720 Series Command Centers (D720, D720W, D720R, D720B)
- D1255 Series Command Centers (D1255, D1255W, D1255R, D1255B)
- D1256 Fire Command Center
- D1257 Remote Fire Alarm Annunciator
- D279A Independent Zone Control
Communications
- Modem IIIa²
Formats
- BFSK
Programming
- D5200 Series Programmers
- Remote Programming Software (RPS)
Modules
- C900TTL-E Dialer Capture Module
- D125B Dual Class B Initiating Module
- D127 Reversing Relay Module
- D129 Class A Initiating Module
- D130 Auxiliary Relay Module
- D185 Reverse Polarity Signaling Module
- D192C Notification Appliance Circuit Module
- D192G Notification Appliance Circuit Module
- D5060 MUX Programmer
- D8125 POPEX Point Expander
- D8128D OctoPOPIT Eight Point Expander
- D8125MUX Point Expander
- D8129 Octo-relay Module
- D9127 Series POPIT Modules
- D9131A Parallel Printer Interface Module
- D9210BLC Access Control Interface Module
- DS7432 Eight-input Remote Module
- DS7457i Series Single Zone Multiplex Input Modules
- DS7460i Two-input Module
- DS7461i Single-input Multiplex Module
- DS7465i Input and Output Module
- DX4010i RS-232 Serial Interface Module
- DX4020 Network Interface Module
- rvm4c Remote Video Module
Peripheral Hardware
- D278S Four-wire Addressable Detector Base
- D285/TH Photoelectric Smoke Detector Heads
- D298S Addressable Detector Base
- D462 Addressable Manual Station
Detectors
- MX250 Series Smoke Detectors
- MX775i Addressable PIR Detector
- MX794i Long Range Multiplex PIR Detector
- MX934i Addressable PIR Detector
- MX938i Addressable PIR Detector
- ZX776Z PIR Detector
- ZX794Z Long Range PIR Detector
- ZX835 TriTech Microwave/PIR Detector
- ZX935Z PIR Detector
- ZX938Z PIR Detector
- ZX970 PIR/Microwave Detector
- Bosch conventional detectors include Blue Line, seismic, PIR, TriTech PIR Microwave, photoelectric, heat, and smoke.
Magnetic Contacts
- Bosch magnetic contacts include recessed, terminal connection, miniature, overhead door, and surface mount.
Wireless Products
- D8125INV Wireless Interface
- FA113 Keychain Remote Control
- FA116 Executive Programmer
- FA202 Wireless Smoke Detector and Transmitter
- FA203S Necklace Pendant Transmitter (Single-button)
- FA203D Necklace Pendant Transmitter (Double-button)
- FA204 Necklace Pendant Transmitter
- FA205S Belt Clip/Loop Transmitter (Single-button)
- FA205D Belt Clip/Loop Transmitter (Double-button)
- FA206DS PIR Transmitter
- FA206i PIR Transmitter
- FA207 Glass Break Detector
- FA209 Billtrap Transmitter
- FA210 Universal Transmitter (Off-White)
- FA210W Universal Wide Gap Transmitter (Off-white) with Internal Reed Switch
- FA216L Low Temperature Transmitter
- FA216H High Temperature Transmitter
- FA223S Water-resistant Pendant (White Single-button)
- FA223D Water-resistant Pendant (Black Double-button)
- FA250 High-power Universal Transmitter
- FA400 Remote Receiver
- FA404R Transmitter Receiver
- FA416R Transmitter Receiver
- FA570 High Power Indoor Repeater
- FA575 High Power Indoor/Outdoor Repeater
Readers
- ARD-R10 iCLASS Mullion Reader
- ARD-R40 iCLASS Switchplate Reader
- ARD-RK40-09 iCLASS PIN Reader
- ARD-VSMART iCLASS Reader
- D8201/W Series Low-profile Readers
- D8203/W Series Mullion Proximity Readers
- D8223 Prox Pro Reader
- D8224 Mullion Reader
- D8224-SP Switch Plate Reader
- D8225 Mini Mullion Reader
- D8227 Insert Card Reader
- D8301/W Series Low-profile Proximity Readers
- D8302 Vandal-resistant Reader
- D8303/W Series Mullion Proximity Readers
- D8304/W Series Extended Range Proximity Readers
- WP612 Series Waterproof Pass-through Readers
- WP644 Series Waterproof Pass-through Readers
SAFECOM Radio Communicators
- SC2104 Series Slave Communicators
- SC3100 Series Data Transfer Radio Communicators
- SC4000 Series Full Data Transfer Radio Communicator
Technical Specifications
Enclosures
- D8103 Universal
- D8108A Attack-Resistant
- D8109 Fire
Communications
- SDI Bus A (+): 9 VDC, 4572 m (15,000 ft)
- SDI Bus B (-): 9 VDC, 4572 m (15,000 ft)
- Telephone Connection: One telephone line; D928 Dual Phone Line Module required for two telephone lines.
Environmental Considerations
- Relative Humidity: 5% to 85% at +30°C (+86°F), non-condensing.
- Temperature (Operating): 0°C to +50°C (+32°F to +120°F).
Number of...
- Areas: 8
- Card Readers (Doors): 8
- Credentials (Tokens): 996
- Custom Functions: 16
- Programmable Relay Outputs: 131
- Events: Up to 1,000
- Passcode Users: 249, plus 1 service passcode
- Parallel Printers: 3
- Points: 246 (8 on-board, up to 238 off-board)
- RF Points: 238
- SKEDs: 64
Power Requirements
- Current Draw (Minimum): 225 mA
- Current Draw (Maximum): 300 mA
- Output (Alarm): 2 A at 12 VDC
- Output (Auxiliary, Continuous Power, and Switched Auxiliary combined): 1.4 A at 10.2 VDC to 13.9 VDC
- Voltage (Operating): 12 VDC
- Voltage (AC): 16.5 VAC 40 VA plug-in transformer (D1640)
- Standby Power: Up to 2 12 VDC, 7 Ah sealed lead acid rechargeable batteries; Up to 2 12 VDC, 18 Ah sealed lead acid rechargeable batteries.
Ordering Information
D9412GV2 Control Panel Models
Product | Model |
---|---|
D9412GV2 Control Panel | D9412GV2 |
D9412GV2 Attack-Resistant Kit | D9412GV2-A |
D9412GV2 Fire and Burglar Kit | D9412GV2-B |
D9412GV2 Commercial Burglar Kit | D9412GV2-C |
Hardware Accessories
Accessory | Part Number |
---|---|
D101 Lock and Key Set | D101 |
D110 Tamper Switch | D110 |
D122 Dual Battery Harness | D122 |
D122L Dual Battery Harness with Long Leads | D122L |
D126 Standby Battery (12 V, 7 Ah) | D126 |
D137 Mounting Bracket | D137 |
D138 Mounting Bracket, Right Angle | D138 |
D928 Dual Phone Line Switcher | D928 |
D1218 Battery (12 V, 18 Ah) | D1218 |
D1224 Battery (12 V, 24 Ah) | D1224 |
D1238 Battery (12 V, 38 Ah) | D1238 |
D1240 Battery (12 V, 4 Ah) | D1240 |
D1640 Transformer | D1640 |
D8103 Enclosure | D8103 |
D8108A Attack Resistant Enclosure | D8108A |
D8109 Fire Enclosure | D8109 |
D9002-5 Mounting Skirt | D9002-5 |
D136 Plug-In Relay | D136 |
Software Options
- RPS D5500C-LPT Kit
- RPS D5500C-USB Kit
D9412GV2 Control Panel Kit Overview
Components | D9412GV2-A | D9412GV2-B | D9412GV2-C |
---|---|---|---|
D9412GV2 Board | 1 | 1 | 1 |
D101F Lock and Key Set | 1 | ||
D122 Dual Battery Harness | 1 | ||
D161 2.1 m (7 ft) Dual Modular Phone Cords | 2 | ||
D928 Dual Phone Line Switcher | 1 | 1 | |
D1640 Transformer | 1 | 1 | 1 |
D8103 Enclosure | 1 | ||
D8108A Attack-Resistant Enclosure | 1 | ||
D8109 Fire Enclosure | 1 |
Contact Information
Americas
Bosch Security Systems
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 585 223 4060
Toll-Free: +1 800 289 0096
Email: security.sales@us.bosch.com
Website: www.boschsecurity.us
Europe, Middle East, Africa
Bosch Security Systems B.V.
P.O. Box 80002
5600 JB Eindhoven, The Netherlands
Phone: +31 (0) 40 27 83955
Fax: +31 (0) 40 27 86668
Email: emea.securitysystems@bosch.com
Website: www.boschsecurity.com
Asia-Pacific
Bosch Security Systems Pte Ltd
38C Jalan Pemimpin
Singapore 577180
Phone: +65 6319 3450
Fax: +65 6319 3499
Email: apr.securitysystems@bosch.com
Website: www.boschsecurity.com
Data subject to change without notice | Printed in USA | F01U008478en-01 | 19. May 2005