Bosch D9412GV3 Control Panel

Brand: Bosch

Product Overview

The Bosch D9412GV3 Control Panel is a powerful solution designed for intrusion, access control, and fire alarm system applications. It offers integrated functionality, allowing users to manage these three critical security aspects through a single system, thereby reducing complexity and enhancing efficiency.

The control panel features a communicator that sends events to selected public switched telephone network (PSTN), IP network, or general packet radio service (GPRS) destinations via four programmable route groups. It supports up to 246 individually identified points, each capable of accommodating normally-open (NO) and normally-closed (NC) devices with end-of-line (EOL) resistor supervision. Points are programmable for fire, fire supervisory, or intrusion applications.

Image Description: The image displays the Bosch D9412GV3 Control Panel unit, a compact black device with indicator lights and ports. It is shown alongside several compatible keypads, including a vacuum fluorescent display model, a touch-screen model, and a standard numeric keypad, illustrating the user interface options.

Key Features

Functions

Programmable Outputs

System Response

User Interface

Advanced Features

Area Configurations

Area programming offers a wide selection of different system configurations. Each area is assigned an account number to define annunciation, control, and reporting functions. Multiple areas can be linked to a shared area which is automatically controlled (hallway or lobby). Area arming can be conditional on other areas (master or associate). Any area can be configured for perimeter and interior arming, not requiring a separate area for this function.

Two Man Rule

The Two Man Rule provides added security by requiring two people to be present at opening or two unique passcodes on the same keypad to disarm an area. Without the second passcode, the system denies entry.

Early Ambush

Early Ambush requires two passcode entries on the same keypad. The first entry disarms the area, and the second entry stops a timer programmed to send a duress event. If the second entry does not occur within the programmed time, a duress event is generated. This feature allows users to inspect the premises and use the system to confirm the area is safe.

Easy Exit Control

The D9412GV3 Control Panel allows changing from one armed state to another without disarming. For example, changing from Master Arm to Perimeter Arm is reported by the panel. This simplifies system operation by reducing keystrokes.

Programmable Passcode-controlled Menu List

Users must enter a passcode before viewing the keypad menu. The display shows only menu options allowed according to the user's authority level, simplifying operation by presenting pertinent information only.

Passcode Follows Scope

This feature restricts passcode arming and disarming to the keypad's immediate local area, even if the keypad can report events from other areas. It simplifies the arming/disarming procedure without limiting other keypad capabilities.

Invisible Walk Test

A menu item allows testing of invisible 24-hour points within the keypad's scope without sending a report to the central station.

Door-Activated Custom Function

A custom function activates when user credentials are presented to a D9210B door controller's reader, behaving as if the user performed a function at the associated keypad.

Passcodes

User passcodes are three to six digits. Each user can be assigned one of 14 customized authority levels in each area, and passcodes can be restricted to operate only during certain times. The Two Man Rule and Early Ambush options require two passcodes for enhanced security.

Communications

The D9412GV3 Control Panel prioritizes and sends reports in Contact ID or Modem IIIa2 formats to four route groups, each with a programmable primary and backup destination. It offers flexible communications for central stations with capabilities such as individual point numbers, opening/closing reports, remote programming attempts, and diagnostic reports. The panel uses DX4020 Ethernet Network Interface Modules and/or ITS-DX4020-G GPRS/GSM Communicators with Conettix D6600 and D6100i Receiver/Gateways, providing a secure path with anti-replay/anti-substitution features and encryption. Both modules support remote programming.

Security and Fire Detection

The D9412GV3 provides eight on-board points and up to 238 additional off-board points. Individual points can be programmed to monitor burglar alarms, fire alarms, and supervision devices.

Commercial Wireless

The Commercial Wireless platform, powered by Inovonics wireless mesh network technology, ensures superior range, reliability, and scalability for commercial applications. It uses a wide range of transmitters and repeaters, offering flexibility and performance. This protocol is exclusive to Commercial Wireless products.

Event Log and Access Control

Event Log

The event log stores up to 1,000 local and transmitted events, including time, date, event, area, point, and user number. The log can be viewed from a keypad or retrieved remotely via RPS. RPS operators can retrieve events periodically, reducing the need for multiple daily calls. An optional report can be sent when the log reaches a programmed threshold.

Access Control

The D9412GV3 provides custom door strike, point shunt, and auto disarming response by area. It features 14 panel-wide access levels with manual and scheduled control. Access events such as 'Access granted', 'No entry', 'Request-to-enter', and 'Request-to-exit' can be stored, viewed, or printed.

Scheduled Events (Skeds) and Fire Test

Scheduled Events (Skeds)

The internal clock and calendar initiate scheduled events (skeds) for functions like arming, disarming, relay control, or point bypassing. The D9412GV3 Control Panel offers:

Fire Test

Activating Fire Test Mode suppresses all reports to the central station. The keypad and annunciator display testing data. An automatic sensor reset feature saves time. At the end of the test, the keypad shows the number of untested points.

Programming, Diagnostics, and Controls

Installers can perform limited on-site programming via keypad for critical parameters (e.g., Account IDs, Central Station and RPS IP addresses, phone numbers, reporting formats). Full programming can be done on-site or remotely (attended or unattended) with RPS. A programmable system passcode prevents unauthorized remote programming.

D9412GV3 Control Panels accommodate up to four separate destinations for primary, alternate, and backup receivers for automatic test reports. When resetting alarms or arming/disarming, the user is identified by name and number.

ROM Updates

An on-site flash update key allows for easy feature enhancements without replacing ROM chips.

Certifications and Approvals

RegionCertificationDetails
USAULAMCX: Central Station Alarm Units (ANSI/UL 1610 and 1635); AMTB: Control Panels, SIA False Alarm Reduction (UL 864 and ANSI/SIA CP-01-2000); AOTX: Local Alarm Units (ANSI/UL 609 and ANSI/UL 464); APAW: Police Station Alarm Units (ANSI/UL 365 and ANSI/UL 464); APOU: Proprietary Alarm Units (ANSI/UL 1076); NBSX: Household Burglar Alarm System Units (ANSI/UL 1023); UOJZ: Control Units, System (ANSI/UL 864); UTOU: Control Units and Accessories, Household System Type (ANSI/UL 985)
FMCSFM7165-1615:0238 FIRE ALARM CONTROL UNIT (COMMERCIAL)
7167-1615:0239 CONTROL UNIT (HOUSEHOLD)
FDNY-CoA6059
FCCDesigned to comply with Part 15

Installation/Configuration Notes

Compatible Products

Keypads

Detectors

Enclosures

Magnetic Contacts

Bosch magnetic contacts include recessed, terminal connection, miniature, overhead door, and surface mount types.

Modules

Programming

Readers

Commercial Wireless Products

Technical Specifications

Environmental Considerations

Number of...

Areas:8
Card Readers (Doors):8
Credentials (Tokens):996
Custom Functions:16
Events:Up to 1000
Passcode Users:249, plus 1 service passcode
Parallel Printers:3
Points:246 (8 on-board, up to 238 off-board)
Programmable Relay Outputs:131
RF Points:238
SKEDS:64

Power Requirements

Communications

Parts Included

Quant.Component
1D9412GV3 Board
1Mounting Skirt
1Faceplate with D9412GV3 Label
1Literature pack
  • Owners Manual
  • Release Notes
1Literature CD containing all product literature

Available Kits

Components-A-B-C
D9412GV3 Board111
D101F Lock and Key Set1
D122 Dual Battery Harness1
D161 Dual Modular Phone Cord2
D928 Dual Phone Line Switcher1
D1640 Transformer11
D8103 Enclosure1
D8108A Attack-resistant Enclosure1
D8109 Fire Enclosure1

Ordering Information

Control Panel

ProductModelDescription
D9412GV3 Control PanelD9412GV3Includes one printed circuit board (PCB) with mounting skirt and faceplate with label, and a literature pack and CD.
D9412GV3-A Attack-resistant PackageD9412GV3-AContains one PCB, one transformer, and one attack-resistant enclosure.
D9412GV3-B Fire/Burglar PackageD9412GV3-BContains one PCB, one dual battery harness, two telephone cords, one telephone line switcher, one transformer, and one fire enclosure.
D9412GV3-C Standard Burglar PackageD9412GV3-CContains one PCB, one lock and key set, one transformer, and one universal enclosure.

Accessories

ProductModelDescription
SDI SplitterICP-SDI-9114Provides the ability to set up two independent SDI buses from a single SDI connection on the control panel.
Tamper SwitchD110Screw-on tamper switch that fits all enclosures. Shipped in packages of two.
Dual Tamper SwitchICP-EZTSCombination tamper switch with a wire loop for additional tamper outputs.
Universal EnclosureD8103Grey steel enclosure measuring 41 cm x 41 cm x 9 cm (16 in. x 16 in. x 3.5 in.).
Attack Resistant EnclosureD8108AGrey steel enclosure measuring 41 cm x 41 cm x 9 cm (16 in. x 16 in. x 3.5 in.). UL Listed. Includes lock and key set. Requires the D2402 Mounting Plate.
Fire EnclosureD8109Red steel enclosure measuring 40.6 cm x 40.6 cm x 8.9 cm (16 in. x 16 in. x 3.5 in). UL Listed. Includes a lock and key set.
Dual Phone Line SwitcherD928Allows the control panel to operate over and supervise two separate phone lines. Only one D162 phone cord is supplied. Two additional D161 or D162 phone cords are required.
Dual Battery HarnessD122Harness with circuit breaker. Connects two batteries to a compatible control panel.
Dual Battery Harness with Long LeadsD122LColor-coded harness with circuit breaker and leads measuring 89 cm (35 in.). Connects 12 V batteries to compatible control panels.

Batteries

ProductModelDescription
Standby Battery (12 V, 7 Ah)D126Sealed lead-acid standby and auxiliary rechargeable power supply.
Battery (12 V, 18 Ah)D1218A 12 V sealed lead-acid battery for standby and auxiliary power with two bolt-fastened terminals. Includes hardware for attaching battery leads or spade connectors.
Battery (12 V, 26-28 Ah)D1224A 12 V sealed lead-acid battery for standby and auxiliary power with two bolt-fastened terminals. Includes hardware for attaching battery leads or spade connectors.

Mounting Brackets

ProductModelDescription
Mounting BracketD137Used to mount accessory modules in D8103, D8108A, and D8109 enclosures.
Mounting Bracket, Right AngleD138Used to mount accessory modules in D8103, D8108A, and D8109 enclosures.

Transformer

ProductModelDescription
TransformerD1640System transformer rated at 16.5 VAC, 40 VA.
Transformer EnclosureD8004For applications such as fire alarm that might require a transformer enclosure.

Mounting Skirt

ProductModelDescription
Mounting SkirtD9002-5Mounts inside D8103, D8108A, and D8109 enclosures. Can accept up to six standard 7.62 cm x 12.7 cm (3 in. x 5 in.) cards.

Lock and Key Set

ProductModelDescription
Lock and Key SetD101Standard lock set with one key supplied. Uses the D102 (#1358) replacement key.

Software Options

ProductModelDescription
RPS Kit (USB)D5500C-USBAccount management and control panel-programming software with USB connection.

Trademarks

Trademark names are used throughout this document. In most cases, these designations are claimed as trademarks or registered trademarks in one or more countries by their respective owners. Rather than placing a trademark symbol in every occurrence of a trademark name, Bosch Security Systems, Inc. uses the names only in an editorial fashion and to the benefit of the trademark owner with no intention of infringing the trademark.

Inovonics is a trademark of Inovonics Wireless Corporation.

PDF preview unavailable. Download the PDF instead.

02502 Antenna House PDF Output Library 2.6.0 (Windows)

Related Documents

Preview Bosch D9412GV2 Control Panel: Integrated Intrusion, Fire, and Access Control System
Detailed overview of the Bosch D9412GV2 Control Panel, an integrated security solution for intrusion detection, fire alarms, and access control, featuring advanced features, connectivity, and compatibility.
Preview Bosch D9412GV4 Control Panel: Integrated Security Solution
Discover the Bosch D9412GV4 Control Panel, a comprehensive commercial security solution integrating intrusion, fire, and access control. Learn about its features, connectivity, and system capabilities for robust security management.
Preview Bosch D9412GV3 Control Panel: Integrated Intrusion, Fire, and Access Control System
Explore the capabilities of the Bosch D9412GV3 Control Panel, a versatile solution for integrated intrusion detection, fire alarm systems, and access control. Learn about its advanced features, communication options, system response, and compatibility with various security components.
Preview Bosch D9412GV2/D7412GV2 Control Panel Troubleshooting Guide
This guide provides detailed troubleshooting procedures for Bosch D9412GV2 and D7412GV2 control panels, addressing common issues related to access control, system points, keypad functions, and central station communications.
Preview Bosch D9412GV2 Control Panel: Integrated Security System
Detailed information on the Bosch D9412GV2 Control Panel, an integrated solution for intrusion detection, fire alarm, and access control. Features include NetCom IP communication, flexible point configuration, advanced security functions, and extensive compatibility with Bosch security products.
Preview Bosch D9412G/D7412G Troubleshooting Guide
This guide provides detailed troubleshooting procedures for Bosch D9412G and D7412G control panels, addressing common issues with access control, point symptoms, keypad operations, and central station communications.
Preview Conettix D6200 Operation and Installation Guide
Comprehensive guide for operating and installing the Bosch Conettix D6200 system, covering network communications, installation procedures, software operation, and troubleshooting.
Preview Bosch D9124 Digital Alarm Communicator and Access Control System (DACS) Specifications
Comprehensive architectural and engineering specifications for the Bosch D9124 DACS, detailing system features, capabilities, materials, installation, testing, and commissioning requirements for fire alarm and security applications.