D9412GV2 Control Panel
The D9412GV2 Control Panel is a fully integrated solution designed for access control, intrusion detection, and fire alarm system applications. It allows users to interface with a single system instead of managing three separate ones, providing comprehensive security monitoring and control.
Key Features
- Fully integrated intrusion, fire, and access control.
- NetCom IP-based communication option for high-speed, secure alarm transport and control.
- Eight programmable areas with perimeter and interior partitioning.
- 246 points with flexible configuration options.
- Choice of vacuum fluorescent or ATM-style user interface command centers.
- New user interface functions for enhanced security and flexibility.
- Up to 238 RF points.
System Overview
The D9412GV2 Control Panel integrates access control, intrusion, and fire alarm functionalities. It monitors alarm points for intruder or fire events while managing user command centers and other outputs. The panel includes a communicator that sends events to Public Switched Telephone Network (PSTN) or IP network destinations via four programmable route groups. System functions can be programmed on-site using a D5200 Programmer or remotely via Remote Programming Software (RPS). It supports up to eight doors of access control with the optional D9210BLC Access Control Interface Module and offers up to 246 individually identified points, each supporting normally-open (NO) and normally-closed (NC) devices with end-of-line (EOL) resistor supervision. Points can be programmed for fire, fire supervisory, or intrusion applications.
Functions
Programmable Outputs
- 2 A alarm power at 12 VDC
- 1.4 A auxiliary power at 12 VDC
- Four alarm output patterns
- Programmable bell test
- Programmable bell shut-off timer
System Response
- 31 custom point indexes, including fire supervisory.
- Selectable point response time.
- Cross point capability.
- Fire alarm verification.
- Fire inspector's local test.
- Watch mode.
- Scheduled events (skeds) for arming, disarming, bypassing points, controlling relays, authority levels, and door access.
User Interface
The system supervises up to eight command centers (or up to 32 unsupervised command centers). It features custom command center text and a full function command menu with custom options. Each user is assigned authority by area and a 16-character name. Fourteen custom authority levels control user permissions for changing passcodes or access control credentials, disarming, bypassing points, and starting system tests. The brightness and volume for the command center display or sounder are adjustable. A command center is required in each system.
Area Configurations
Area programming offers a wide selection of system configurations. Each area can be assigned an account number to define annunciation, control, and reporting functions. Multiple areas can be linked to an automatically controlled shared area, such as a hallway or lobby. Area arming can be conditional on other areas (master and associate).
Advanced Security Features
Two Man Rule
Requires two unique passcodes entered at the same command center to disarm an area. Without the second passcode, entry is denied. This feature ensures the presence of two people at opening for added security, particularly in financial institutions.
Early Ambush
Requires two passcode entries on the same command center. The first entry disarms the area, and the second entry stops a timer programmed to send a duress event. If the second entry is not made within the programmed time, a duress event is generated. This allows users to inspect premises safely before full system disarming.
Easy Exit Control
Allows the D9412GV2 Control Panel to change from one armed state to another without disarming, simplifying operation and reducing keystrokes. For example, changing from Master Arm to Perimeter Arm is handled seamlessly.
Passcode-controlled Menu List
Users must enter a passcode before viewing the command center menu. The display shows only menu options permitted by the user's authority level, simplifying operation by presenting relevant information and functions.
Passcode Follows Scope
Restricts passcode arming and disarming to the command center's immediate local area, even if the command center can report events from other areas. This simplifies arming/disarming without limiting other command center capabilities.
Invisible Walk Test
A menu item enables testing of invisible 24-hour points within the command center's scope without sending reports to the central station.
Door Activated Custom Function
A custom function is activated when user credentials are presented to a D9210B door controller's reader. This function mimics a manual operation performed at the command center associated with that door controller.
Passcodes
User passcodes consist of three to six digits. Each user can be assigned one of fourteen customized authority levels per area. Passcodes can be restricted to operate only during specific times. The Two Man Rule and Early Ambush options require two passcodes, enhancing security in sensitive environments like banks.
Communications
The D9412GV2 Control Panel prioritizes and sends reports to four route groups, each with a programmable primary and backup destination. It integrates with the D6600 NetCom Communications System via a DX4020 Network Interface Module, offering programmable anti-replay and anti-substitution features. The Modem IIIa2 Communications Format, compatible with Bosch receivers, provides advanced reporting capabilities, including individual point numbers and text, opening/closing reports by area, remote programming attempts, diagnostic reports, and user name transmission to the central station.
Security and Fire Detection
The control panel includes eight on-board points and supports up to 238 additional off-board points (depending on model and expansion interfaces). Individual points can be programmed to monitor various alarm types, including burglar alarms, fire alarms, and supervision devices.
Event Log
The event log stores up to 1,000 local and transmitted events, including time, date, event type, area, point, and user number. The log can be viewed from select command centers or retrieved remotely using RPS. RPS operators can collect events periodically with a single call. An optional report can be sent to a receiver when the event log reaches a programmed threshold.
Access Control
The D9412GV2 provides custom door strike, point shunt, and auto disarming responses by area. It features 14 panel-wide access levels with manual and scheduled control. Access events such as 'Access granted', 'No entry', 'Request-to-enter', and 'Request-to-exit' can be stored, viewed, or printed.
Scheduled Events (Skeds)
The internal clock and calendar enable scheduled events (skeds) to perform functions like arming/disarming, relay control, or point bypassing. The D9412GV2 Control Panel supports up to 40 scheduled events with 25 different functions, eight opening windows, eight closing windows, eight user windows, and day-of-week, date-of-month, or holiday-only schedules. It includes four holiday schedules covering 366 days each.
Fire Test
Activating Fire Test Mode suppresses all reports to the central station, while the command center and annunciator display all testing data. An automatic sensor reset feature simplifies testing by eliminating manual resets. At the end of the test, the command center indicates the number of untested points.
Programming, Diagnostics and Controls
Users can program the system on-site using a D5200 Programmer or remotely via RPS. A programmable system passcode prevents unauthorized remote programming. The D9412GV2 Control Panels accommodate up to four separate telephone numbers for primary, alternate, and backup receivers for automatic test reports. System resets, arming, and disarming actions identify the user by name and number.
Parts Included
Component | Quantity |
---|---|
D9412GV2 Board | 1 |
Mounting Skirt | 1 |
Faceplate with D9412GV2 Label | 1 |
Certifications and Approvals
The D9414GV2 Control Panel is designed to comply with the following certifications, standards, and approvals:
UL Standards Approvals
- UL365, Police Station Burglar Alarm Units and Systems
- UL464, Audible Signal Appliances
- UL609, Local Burglar Alarm Units and Systems
- UL864, Control Units for Fire-protective Signaling Systems
- UL985, Household Fire Warning System Units
- UL1023, Household Burglar-alarm System Units
- UL1076, Proprietary Burglar Alarm Units and Systems
- UL1610, Central-station Burglar-alarm Units
- UL1635, Digital Alarm Communicator System Units
FCC: AJ9MLU-46532-AL-E
Installation/Configuration Notes
Compatible Products
Command Centers
- D1260 Series Command Centers (D1260, D1260W, D1260R, D1260BLK, D1260B)
- D720 Series Command Centers (D720, D720W, D720R, D720B)
- D1255 Series Command Centers (D1255, D1255W, D1255R, D1255B)
- D1256 Fire Command Center
- D1257 Remote Fire Alarm Annunciator
- D279A Independent Zone Control
Communications Formats
- Modem IIIa2
- BFSK
Programming
- D5200 Series Programmers
- Remote Programming Software (RPS)
- D5060 MUX Programmer
Modules
- C900TTL-E Dialer Capture Module
- D125B Dual Class B Initiating Module
- D127 Reversing Relay Module
- D129 Class A Initiating Module
- D130 Auxiliary Relay Module
- D185 Reverse Polarity Signaling Module
- D192C Notification Appliance Circuit Module
- D192G Notification Appliance Circuit Module
- D8125 POPEX Point Expander
- D8128D OctoPOPIT Eight Point Expander
- D8125MUX Point Expander
- D8129 Octo-relay Module
- D9127 Series POPIT Modules
- D9131A Parallel Printer Interface Module
- D9210BLC Access Control Interface Module
- DX4010i RS-232 Serial Interface Module
- DX4020 Network Interface Module
- rvm4c Remote Video Module
Peripheral Hardware
Detectors
- D278S Four-wire Addressable Detector Base
- D285/TH Photoelectric Smoke Detector Heads
- D298S Addressable Detector Base
- D462 Addressable Manual Station
- MX250 Series Smoke Detectors
- MX775i Addressable PIR Detector
- MX794i Long Range Multiplex PIR Detector
- MX934i Addressable PIR Detector
- MX938i Addressable PIR Detector
- ZX776Z PIR Detector
- ZX794Z Long Range PIR Detector
- ZX835 TriTech Microwave/PIR Detector
- ZX935Z PIR Detector
- ZX938Z PIR Detector
- ZX970 PIR/Microwave Detector
- Bosch conventional detectors include Blue Line, seismic, PIR, TriTech PIR Microwave, photoelectric, heat, and smoke.
Magnetic Contacts
- Bosch magnetic contacts include recessed, terminal connection, miniature, overhead door, and surface mount.
Wireless Products
- D8125INV Wireless Interface
- FA113 Keychain Remote Control
- FA116 Executive Programmer
- FA202 Wireless Smoke Detector and Transmitter
- FA203S Necklace Pendant Transmitter (Single-button)
- FA203D Necklace Pendant Transmitter (Double-button)
- FA204 Necklace Pendant Transmitter
- FA205S Belt Clip/Loop Transmitter (Single-button)
- FA205D Belt Clip/Loop Transmitter (Double-button)
- FA206DS PIR Transmitter
- FA206i PIR Transmitter
- FA207 Glass Break Detector
- FA209 Billtrap Transmitter
- FA210 Universal Transmitter (Off-White)
- FA210W Universal Wide Gap Transmitter (Off-white) with Internal Reed Switch
- FA216L Low Temperature Transmitter
- FA216H High Temperature Transmitter
- FA223S Water-resistant Pendant (White Single-button)
- FA223D Water-resistant Pendant (Black Double-button)
- FA250 High-power Universal Transmitter
- FA400 Remote Receiver
- FA404R Transmitter Receiver
- FA416R Transmitter Receiver
- FA570 High Power Indoor Repeater
- FA575 High Power Indoor/Outdoor Repeater
Readers
- ARD-R10 iCLASS Mullion Reader
- ARD-R40 iCLASS Switchplate Reader
- ARD-RK40-09 iCLASS PIN Reader
- ARD-VSMART iCLASS Reader
- D8201/W Series Low-profile Readers
- D8203/W Series Mullion Proximity Readers
- D8223 Prox Pro Reader
- D8224 Mullion Reader
- D8224-SP Switch Plate Reader
- D8225 Mini Mullion Reader
- D8227 Insert Card Reader
- D8301/W Series Low-profile Proximity Readers
- D8302 Vandal-resistant Reader
- D8303/W Series Mullion Proximity Readers
- D8304/W Series Extended Range Proximity Readers
- WP612 Series Waterproof Pass-through Readers
- WP644 Series Waterproof Pass-through Readers
Communicators
- SAFECOM Radio SC2104 Series Slave Communicators
- SC3100 Series Data Transfer Radio Communicators
- SC4000 Series Full Data Transfer Radio Communicator
Technical Specifications
Enclosures
- D8103 Universal
- D8108A Attack-Resistant
- D8109 Fire
Communications
- SDI Bus A (+): 9 VDC, 4572 m (15,000 ft)
- SDI Bus B (-): 9 VDC, 4572 m (15,000 ft)
- Telephone Connection: One telephone line (D928 Dual Phone Line Module required for two telephone lines)
Environmental Considerations
- Relative Humidity: 5% to 85% at +30°C (+86°F), non-condensing
- Temperature (Operating): 0°C to +50°C (+32°F to +120°F)
Power Requirements
- Current Draw (Minimum): 225 mA
- Current Draw (Maximum): 300 mA
- Output (Alarm): 2 A at 12 VDC
- Output (Auxiliary, Continuous Power, and Switched Auxiliary combined): 1.4 A at 10.2 VDC to 13.9 VDC
- Voltage (Operating): 12 VDC
- Voltage (AC): 16.5 VAC, 40 VA plug-in transformer (D1640)
- Standby Power: Up to 2 x 12 VDC, 7 Ah sealed lead acid rechargeable batteries; Up to 2 x 12 VDC, 18 Ah sealed lead acid rechargeable batteries
Specifications Summary
Specification | Value |
---|---|
Areas | 8 |
Card Readers (Doors) | 8 |
Credentials (Tokens) | 996 |
Custom Functions | 16 |
Programmable Relay Outputs | 131 |
Events | Up to 1,000 |
Passcode Users | 249, plus 1 service passcode |
Parallel Printers | 3 |
Points | 246 (8 on-board, up to 238 off-board) |
RF Points | 238 |
SKEDs | 64 |
Ordering Information
Control Panel
Product | Model Number |
---|---|
D9412GV2 Control Panel | D9412GV2 |
D9412GV2 Attack-Resistant Kit | D9412GV2-A |
D9412GV2 Fire and Burglar Kit | D9412GV2-B |
D9412GV2 Commercial Burglar Kit | D9412GV2-C |
Hardware Accessories
Hardware Accessory | Part Number |
---|---|
Lock and Key Set | D101 |
Tamper Switch | D110 |
Dual Battery Harness | D122 |
Dual Battery Harness with Long Leads | D122L |
Standby Battery (12 V, 7 Ah) | D126 |
Mounting Bracket | D137 |
Mounting Bracket, Right Angle | D138 |
Dual Phone Line Switcher | D928 |
Battery (12 V, 18 Ah) | D1218 |
Battery (12 V, 24 Ah) | D1224 |
Battery (12 V, 38 Ah) | D1238 |
Battery (12 V, 4 Ah) | D1240 |
Transformer | D1640 |
Enclosure | D8103 |
Attack Resistant Enclosure | D8108A |
Fire Enclosure | D8109 |
Mounting Skirt | D9002-5 |
Plug-In Relay | D136 |
Software Options
Software Option | Part Number |
---|---|
RPS D5500C-LPT Kit | D5500C-LPT |
RPS D5500C-USB Kit | D5500C-USB |
D9412GV2 Control Panel Kit Overview
Components | Kits | ||
---|---|---|---|
D9412GV2-A | D9412GV2-B | D9412GV2-C | |
D9412GV2 Board | 1 | 1 | 1 |
D101F Lock and Key Set | 1 | ||
D122 Dual Battery Harness | 1 | 2 | 1 |
D161 2.1 m (7 ft) Dual Modular Phone Cords | 1 | ||
D928 Dual Phone Line Switcher | 1 | 1 | |
D1640 Transformer | 1 | 1 | 1 |
D8103 Enclosure | 1 | ||
D8108A Attack-Resistant Enclosure | 1 | ||
D8109 Fire Enclosure | 1 |
Contact Information
Americas
Bosch Security Systems
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone:+1 585 223 4060
+1 800 289 0096
security.sales@us.bosch.com
http://www.boschsecurity.us
Europe, Middle East, Africa
Bosch Security Systems B.V.
P.O. Box 80002
5600 JB Eindhoven, The Netherlands
Phone:+31 (0) 40 27 83955
Fax:+31 (0) 40 27 86668
emea.securitysystems@bosch.com
http://www.boschsecurity.com
Asia-Pacific
Bosch Security Systems Pte Ltd
38C Jalan Pemimpin
Singapore 577180
Phone:+65 6319 3450
Fax:+65 6319 3499
apr.securitysystems@bosch.com
http://www.boschsecurity.com
Data subject to change without notice | Printed in USA | F01U008478en-01 | 19. May 2005