D9412GV3 Control Panel

Bosch Security Systems

Website: www.boschsecurity.com

Product Description: The D9412GV3 Control Panel is a powerful solution for integrated intrusion, access control, and fire alarm system applications.

Key Features and Capabilities

The D9412GV3 Control Panel offers:

The control panel includes a communicator that sends events to selected public switched telephone network (PSTN), IP network, or general packet radio service (GPRS) destinations through four programmable route groups. It provides up to 246 individually identified points, each capable of accommodating normally-open (NO) and normally-closed (NC) devices with end-of-line (EOL) resistor supervision, and programmable for fire, fire supervisory, or intrusion applications.

With the D9412GV3, users can:

Functions

Programmable Outputs

System Response

User Interface

Advanced Features and Configurations

User Authority and Area Management

Area Configurations

Area programming offers a wide selection of different system configurations. Each area is assigned an account number to define annunciation, control, and reporting functions. Multiple areas can be linked to a shared area (e.g., hallway or lobby) for automatic control. Area arming can be conditional on other areas (master or associate). Any area can be configured for perimeter and interior arming without requiring a separate area.

Security Protocols

Passcodes

User passcodes are three to six digits. Each user can be assigned one of 14 customized authority levels per area. Passcodes can be restricted to operate only during certain times. The Two Man Rule and Early Ambush options require two passcodes for enhanced security in financial establishments.

Communications and Connectivity

Communications

The D9412GV3 Control Panel prioritizes and sends reports in Contact ID or Modem IIIa² formats to four programmable route groups, each with primary and backup destinations. It provides flexible communications for most central stations, supporting individual point numbers, opening/closing reports, remote programming attempts, and diagnostic reports.

The panel utilizes the DX4020 Ethernet Network Interface Module and/or the ITS-DX4020-G GPRS/GSM Communicator to connect with Conettix D6600 and D6100i Communications Receiver/Gateways. Conettix IP communication offers a secure path with anti-replay/anti-substitution features and encryption. Both modules support remote programming.

Security and Fire Detection

The D9412GV3 provides eight on-board points and up to 238 additional off-board points (depending on model and expansion interfaces). Individual points can be programmed to monitor various alarm types, including burglar alarms, fire alarms, and supervision devices.

Commercial Wireless

The Commercial Wireless platform, powered by Inovonics wireless mesh network technology, ensures superior range, reliability, and scalability for commercial applications. This proven technology offers flexibility and performance. It sends redundant information on multiple frequency channels within the FCC Part 15 900 MHz band, providing enhanced range and reliability compared to single-frequency systems.

Event Management and Access Control

Event Log

The event log stores up to 1,000 local and transmitted events, including time, date, event, area, point, and user number. Events can be viewed from a keypad or retrieved remotely using RPS. RPS operators can retrieve events periodically via a single phone call. The system can send optional reports when the event log reaches a programmed threshold.

Access Control

The D9412GV3 supports custom door strike, point shunt, and auto disarming response by area. It features 14 panel-wide access levels with manual and scheduled control. Users can store, view, or print access events such as 'Access granted', 'No entry', 'Request-to-enter', and 'Request-to-exit'.

Scheduled Events (Skeds)

The internal clock and calendar manage scheduled events (skeds) to perform functions like arming/disarming, relay control, or point bypassing. The D9412GV3 offers:

Fire Test

When Fire Test Mode is activated, the control panel suppresses all reports to the central station. The keypad and annunciator display testing data. An automatic sensor reset feature saves time, eliminating manual sensor resets. At the end of the test, the keypad indicates the number of untested points.

Programming, Diagnostics, and Updates

Programming, Diagnostics, and Controls

Installers can perform limited on-site programming using a keypad for critical parameters (e.g., Account IDs, Central Station and RPS IP addresses, phone numbers, reporting formats). Full programming can be done on-site or remotely (attended or unattended) with RPS. A programmable system passcode prevents unauthorized remote programming.

D9412GV3 Control Panels support up to four separate destinations for primary, alternate, and backup receivers for automatic test reports. User identification (name and number) is logged when resetting alarms or arming/disarming the system.

ROM Updates

An on-site flash update key allows for easy feature enhancements without requiring ROM chip replacement.

Commercial Fire Alarm Support

The system is suitable for Commercial Fire applications compliant with UL 864, 9th Edition.

Certifications and Approvals

RegionCertificationDetails
USAULAMCX: Central Station Alarm Units (ANSI/UL 1610 and 1635); AMTB: Control Panels, SIA False Alarm Reduction (UL 864 and ANSI/SIA CP-01-2000); AOTX: Local Alarm Units (ANSI/UL 609 and ANSI/UL 464); APAW: Police Station Alarm Units (ANSI/UL 365 and ANSI/UL 464); APOU: Proprietary Alarm Units (ANSI/UL 1076); NBSX: Household Burglar Alarm System Units (ANSI/UL 1023); UOJZ: Control Units, System (ANSI/UL 864); UTOU: Control Units and Accessories, Household System Type (ANSI/UL 985)
FM7167-1615:0239 CONTROL UNIT (HOUSEHOLD)
CSFM7165-1615:0238 FIRE ALARM CONTROL UNIT (COMMERCIAL)
CSFM7167-1615:0239
FDNY CoA6059 [D9412GV3 & D7412GV3]

FCC: Designed to comply with Part 15.

Installation and Configuration Notes

Compatible Products

Keypads

Detectors

Enclosures

Magnetic Contacts

Bosch magnetic contacts include recessed, terminal connection, miniature, overhead door, and surface mount types.

Modules

Programming

Readers

Commercial Wireless Products

Parts Included and Technical Specifications

Parts Included

The D9412GV3 includes the following parts:

Quant.Component
1D9412GV3 Board
1Mounting Skirt
1Faceplate with D9412GV3 Label
1Literature pack (Installation Instructions, Owners Manual, Release Notes)
1Literature CD containing all product literature

The available kits include:

ComponentsKit -AKit -BKit -C
D9412GV3 Board111
D101F Lock and Key Set1
D122 Dual Battery Harness1
D161 Dual Modular Phone Cord2
D928 Dual Phone Line Switcher1
D1640 Transformer11
D8103 Enclosure1
D8108A Attack-resistant Enclosure1
D8109 Fire Enclosure1

Technical Specifications

Communications

Environmental Considerations

System Parameters

Power Requirements

Trademarks

Trademark names are used throughout this document. In most cases, these designations are claimed as trademarks or registered trademarks by their respective owners. Bosch Security Systems, Inc. uses these names in an editorial fashion for the benefit of the trademark owner, with no intention of infringing the trademark.

Inovonics is a trademark of Inovonics Wireless Corporation.

Ordering Information

Control Panel Packages

Accessories

Software Options

Represented By

Americas: Bosch Security Systems, Inc., 130 Perinton Parkway, Fairport, New York, 14450, USA. Phone: +1 800 289 0096. Fax: +1 585 223 9180. Email: security.sales@us.bosch.com. Website: www.boschsecurity.us

Europe, Middle East, Africa: Bosch Security Systems B.V., P.O. Box 80002, 5617 BA Eindhoven, The Netherlands. Phone: +31 40 2577 284. Fax: +31 40 2577 330. Email: emea.securitysystems@bosch.com. Website: www.boschsecurity.com

Asia-Pacific: Robert Bosch (SEA) Pte Ltd, Security Systems, 11 Bishan Street 21, Singapore 573943. Phone: +65 6571 2808. Fax: +65 6571 2699. Email: apr.securitysystems@bosch.com. Website: www.boschsecurity.asia

China: Bosch (Shanghai) Security Systems Ltd., 201 Building, No. 333 Fuquan Road, North IBP, Changning District, Shanghai 200335 China. Phone: +86 21 22181111. Fax: +86 21 22182398. Website: www.boschsecurity.com.cn

America Latina: Robert Bosch Ltda Security Systems Division, Via Anhanguera, Km 98, Campinas, Sao Paulo, Brazil, CEP 13065-900. Phone: +55 19 2103 2860. Fax: +55 19 2103 2862. Email: latam.boschsecurity@bosch.com. Website: www.boschsecurity.com

Bosch Security Systems © 2014 | Data subject to change without notice. Document number: 2491786379 | Version: en, V6, 27. May 2014

PDF preview unavailable. Download the PDF instead.

D9412GV3 AH Formatter V5.3 MR3 (5,3,2011,1116) for Windows (x64) Antenna House PDF Output Library 2.6.0 (Windows (x64))

Related Documents

Preview Bosch D9412GV3 Control Panel: Features, Specifications, and Ordering Information
Detailed technical overview of the Bosch D9412GV3 Control Panel, covering its integrated intrusion, fire, and access control capabilities, advanced features, communication options, certifications, compatible products, and ordering information.
Preview Bosch D9412GV2 Control Panel: Integrated Security System
Detailed information on the Bosch D9412GV2 Control Panel, an integrated solution for intrusion detection, fire alarm, and access control. Features include NetCom IP communication, flexible point configuration, advanced security functions, and extensive compatibility with Bosch security products.
Preview Bosch D9124 Digital Alarm Communicator and Access Control System (DACS) Specifications
Comprehensive architectural and engineering specifications for the Bosch D9124 DACS, detailing system features, capabilities, materials, installation, testing, and commissioning requirements for fire alarm and security applications.
Preview Bosch D9412GV2 Control Panel: Integrated Intrusion, Fire, and Access Control System
Detailed overview of the Bosch D9412GV2 Control Panel, an integrated security solution for intrusion detection, fire alarms, and access control, featuring advanced features, connectivity, and compatibility.
Preview Bosch D9412GV2/D7412GV2 Control Panel Troubleshooting Guide
This guide provides detailed troubleshooting procedures for Bosch D9412GV2 and D7412GV2 control panels, addressing common issues related to access control, system points, keypad functions, and central station communications.
Preview Bosch D9412GV4 Control Panel: Integrated Security Solution
Discover the Bosch D9412GV4 Control Panel, a comprehensive commercial security solution integrating intrusion, fire, and access control. Learn about its features, connectivity, and system capabilities for robust security management.
Preview Bosch D9412GV2/D7412GV2 Approved Applications Compliance Guide
This guide details the approved applications and compliance for Bosch D9412GV2 and D7412GV2 control panels, covering burglary, fire, and bank safe/vault systems, along with compatible components and wiring diagrams.
Preview Bosch Control Panel Solution 2000/3000 Installation Guide
Comprehensive installation guide for the Bosch Control Panel Solution 2000 and Solution 3000 series, covering system overview, configuration, operation, and accessories. Designed for trained installers.