Vector VT-50 XT Radio Test Report
Viva-Telecom ZAO
https://viva-telecom.org
Test Protocol for Radio Station
Model: Vector VT-50 XT
Article, Version: 214
Date of Testing: 23.06.2025
Transmitter
SELF-TEST
Parameter | Power, W (RF output power) | Frequency, MHz | MID | LOW | Standard | Measured | Standard | Measured |
Frequency, MHz | 433.075 | 6.97 | 1.69 | 10 | 54.7 |
Transmitter Sound Distortion, %
Parameter | Standard | Measured | Standard | Measured |
Receiver
Sensitivity (ГОСТ 12252-86. 12 dB SINAD)
Frequency, MHz | dBm | Standard | Measured | Blocking of Receiver (Useful signal -100 dBm, FM 1 kHz. Type. 80, SG 87 dB) | Selectivity by adjacent channel, dB (Deviation 60% of maximum, FM 400 Hz. 12 dB SINAD) |
433.075 | -126 | 0.11 | 74 | WIDE, 25 kHz: 62 | NARROW, 12.5 kHz: |
Power Supply
Model, Chemical Composition:
Parameter | Value | Parameter | Value | |
Battery Charging Current, A | 0.45 | Maximum Battery Load Current, A | 4.888 | |
Voltage at Battery Terminals during Test, V | 8.35 | Short-circuit Protection Response Time, msec | 6 | |
Current of Radio Station in Off State, µA | 79 | Battery Charge Protection Voltage, V | 8.5 | |
Internal Resistance of Battery, mΩ | 249 | Battery Discharge Protection Voltage, V | 4.685 | |
Current Consumption | Analog Mode (A) | Digital Mode (D) | Standard | Measured |
Standby Current, mA | 29 (save 1/4) | |||
Receive Current at Maximum Volume, mA | 230 | |||
Transmit Current at High Power, mA | 1981 | |||
Measured Battery Capacity, mA*h | 2139 | Battery Life in 5/5/90 Cycle, hours | 2600 | |
15.6 (save 1/4) |
Sound
Parameter | Analog Mode | Digital Mode | Standard | Measured |
Internal Speaker, dB | ||||
Headset Output, mW | ||||
Receiver Audio Distortion (Carrier -70 dBm), % |
Antenna
Frequency, MHz | Minimum VSWR Value | Impedance, Ohm |
416 | 1.86 (wideband) | 52 |
Conclusions
Advantages
- Superheterodyne receiver
Disadvantages
- Battery capacity lower than stated
- Accessory and programmer connector for Motorola CP
Prepared by: V. V. Kalinin
E-mail: support@viva-telecom.org
Note: All measurements are for reference purposes only.
Final Assessment
4