Vector 733 Watt Lithium Power Station

Instruction Manual

Model Numbers: VECLIPS4 / VECLIPS6

Overview and Features

The Vector 733 Watt Lithium Power Station is a versatile portable power solution designed for household use. It features a robust lithium polymer battery and a pure sine wave inverter.

Key Features:

LCD Display Explained:

The LCD screen provides real-time information:

Control Panel Buttons:

The control panel allows users to manage the power station's functions:

When multiple ports are active, the total output power and remaining use time are displayed. A fault icon will flash if an issue occurs, and the affected output will automatically shut down after 10 seconds.

What's in the Box

The package includes:

Safety Guidelines and Instructions

Read all instructions carefully before operating the power station. Failure to follow these instructions may result in electric shock, fire, or serious injury.

Definitions:

General Safety Warnings:

Specific Safety Instructions for Charging:

Before First Use:

Charging with the Home Charger:

Optional Charging via USB-C PD:

Solar Panel Charging:

Specific Safety Instructions for Inverters (AC Output):

Specific Safety Instructions for USB-A & USB-C Ports:

Wireless Charging:

Specific Safety Instructions for 12V DC Output:

LED Area Light:

Troubleshooting

Refer to the following table for common issues and solutions:

IssuePossible CauseSolution
Unit not chargingAll functions not off; AC power source connection; No functioning AC current.Ensure all functions are OFF. Check AC power source connection. Confirm AC current is active.
Wireless Charging function will not charge applianceWireless button not pressed; Appliance not centered; Appliance not compatible.Press the Wireless Charging Button. Place appliance in the center of the pad. Check appliance manual for wireless charging compatibility. Ensure unit has sufficient charge.
USB Power Port will not power applianceUSB button not pressed; USB port fault; Appliance not compatible.Press the USB Power Button. Refer to LCD Warning Symbols for USB port faults. Check appliance manual for USB compatibility. Ensure unit has sufficient charge.
120 Volt AC outlet will not power applianceAC Power Button not turned on; Incorrect procedure; Appliance draw exceeds 500W.Ensure the AC Power Button is turned ON. Follow operating instructions carefully. Ensure combined appliance draw does not exceed 500 watts. Ensure unit has sufficient charge.
Use of photovoltaic solar panel charging faultOver-current; Weak sunlight; Abnormal wire harness connection.Use solar panels with recommended specifications. Place panels in direct sunlight. Reconnect wire harness. Replace solar panels if problem persists.
LED area light does not come ONArea light button not pressed; Unit not charged.Press the area light power button. Ensure unit has sufficient charge.

LCD Warning Symbols:

Specifications

SpecificationDetails
Internal Battery CapacityLithium Polymer; 666WH (VECLIPS6) / 444WH (VECLIPS4)
AC Charging Input19V 4.73A
Solar Input11~30V DC
Output Total733 Watt
AC Output2 x 110VAC/60Hz 500W Pure Sine Wave
USB-C Output18W + 60W PD
USB-A Output2x 5V, 3.1A, 15W
DC Output12V 10A, 120W
Wireless Charging10W MAX
LED Light10W MAX

Warranty and Service

This product is covered by a Two-Year Limited Home Use Warranty against defects in materials and workmanship. For service, technical advice, or replacement parts, contact Baccus Global LLC at 1-877-571-2391. Register your product online at www.baccusglobal.com/register.

FCC Compliance

This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: it may not cause harmful interference, and it must accept any interference received. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

This equipment has been tested and found to comply with the limits for a Class B digital device, designed to provide reasonable protection against harmful interference in a residential installation. It generates, uses, and can radiate radio frequency energy, and may cause interference if not installed and used according to instructions.

If interference occurs, users are encouraged to try correcting it by: reorienting the antenna, increasing separation between equipment and receiver, or connecting to a different circuit. Consult a dealer or experienced technician for help.

To maintain compliance with FCC's RF Exposure guidelines, install and operate with a minimum distance of 20cm between the radiator and your body. Use only the supplied antenna.

FCC ID: 2AZ48-VECLIPS4

Models: VECLIPS4, 2AZ48-VECLIPS4, 2AZ48VECLIPS4, VECLIPS6 733 Watt Lithium Power Station, VECLIPS6, VECLIPS4, 733 Watt Lithium Power Station

PDF preview unavailable. Download the PDF instead.

VECLIPS4-Users-Manual-Baccus-Global-2az48-veclips4-ex-1-4 Adobe PDF library 16.04 Adobe Illustrator 26.2 (Windows)

Related Documents

PreviewVector Professional Power Station Instruction Manual
Comprehensive instruction manual for the Vector Professional Power Station (PPRH5V). Covers features, safety guidelines, operation for jump starting, air compression, and power supply, along with maintenance and troubleshooting.
PreviewVector Professional Power Station Instruction Manual
Comprehensive instruction manual for the Vector Professional Power Station, covering features, operation, safety guidelines, troubleshooting, and specifications for jump-starting, air compression, and AC/USB power output.
PreviewVECTOR SS6LV Lithium Jump-Starter & USB Power Bank Instruction Manual
This manual provides comprehensive instructions for the VECTOR SS6LV Lithium Jump-Starter and USB Power Bank, covering safety guidelines, operating procedures, charging methods, maintenance, troubleshooting, and specifications.
PreviewVECTOR PPRH5V Professional Power Station Instruction Manual
Comprehensive instruction manual for the VECTOR PPRH5V Professional Power Station, covering features, safety guidelines, operation, troubleshooting, and specifications for jump starting, power supply, and air compression.
PreviewVector VT-50 XT Radio Test Report
This document presents the test results for the Vector VT-50 XT radio, including parameters such as transmitter power, receiver sensitivity, power consumption, and audio characteristics. It details measurements against specified standards and provides an overall assessment.
PreviewVector SS6LV Lithium Jump-Starter & USB Power Bank Instruction Manual
Comprehensive instruction manual for the Vector SS6LV Lithium Jump-Starter & USB Power Bank, covering safety guidelines, operating instructions, charging procedures, care and maintenance, troubleshooting, and specifications.
PreviewVector Power City Multi-Function AC/DC Jumpstart System Owner's Manual
Owner's manual and warranty information for the Vector Power City Multi-Function AC/DC Jumpstart System (Model VEC029AC), detailing its features, operation, safety instructions, and specifications for jumpstarting, power inversion, air compression, and lantern functions.
PreviewvSECC Communication Controller for High Power Charging Stations
The vSECC is a communication controller for high power charging stations, acting as an interface between the electric vehicle, charging station management system (CSMS), and power electronics. It supports various charging protocols including ISO 15118, DIN SPEC 70121, CHAdeMO, and OppCharge, and is designed for immediate installation in switching cabinets.