Dacor DRT304S, DRT366S Distinctive 30" and 36" Wide, Slide-in Gas Rangetops
PLANNING GUIDE
Document # PG04-003 | Revised 10/17/14 | Page 1/4
WARNING
Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.
This appliance must be installed in accordance with the accompanying installation instructions.
Electrical and Gas Supply Requirements
ELECTRIC CIRCUIT REQUIREMENTS
Circuit Required | Total Connected Load |
120 Vac 60Hz, 15 Amp. (3 wire) | 1.0 Amp @ 120 Vac, 60 Hz. |
GAS SUPPLY PRESSURE REQUIREMENTS*
Gas Type | Manifold Pressure | Minimum Gas Supply Pressure |
---|---|---|
Natural Gas | 5" Water Column | 6" Water Column |
Propane (LP) | 10" Water Column | 11" Water Column |
* Maximum gas supply pressure for all models is 1/2 p.s.i.
Product Dimensions
Diagram illustrating overall product dimensions. Shows the rangetop width (A) as 29 7/8" (75.9 cm) for DRT304S and 35 7/8" (91.1 cm) for DRT366S. Includes trim thickness of 1/2" (1.3 cm). The cooking surface height (grate level) above the countertop is 1 5/8" (4.1 cm). The power cord is 32" (81.3 cm) long. The 3/4" gas inlet connects to the regulator from the bottom or rear of the unit and is recessed 2" (5.1 cm) from the chassis bottom. Product tolerances are noted as ±1/16" (±1.6 mm) unless otherwise noted.
Cabinet and Countertop Layout
Diagram showing side views. The first view illustrates a minimum clearance of 2 1/2" (6.4 cm) to a combustible rear wall. The second view, labeled "SIDE VIEW WITHOUT BACKGUARD," indicates that a backguard is mandatory if the gap from the back of the cooktop to a combustible wall is less than 2 1/2".
Cabinet and Countertop Layout (continued)
Diagram showing the front view of cabinet and countertop installation. It specifies a minimum clearance of 10" (25.4 cm) to combustible side walls on both sides, and a 1/2" (1.3 cm) overhang on both sides. The typical countertop thickness is 1 1/2" (3.8 cm). A mounting platform of 1" (2.5 cm) minimum thickness is shown. A recommended location for gas and electrical service is indicated, advising consultation with local code. The typical unit height is 36" (91.4 cm).
CABINET/COUNTERTOP DIMENSIONS - FRONT VIEW
Model No. | B | C |
---|---|---|
DRT304S | 30" (76.2 cm) | 30" (76.2 cm)* |
DRT366S | 36" (91.4 cm) | 36" (91.4 cm)** |
* Minimum ** Recommended
Diagram showing an ISO view of the cabinet installation, highlighting the grate level, cutout for utility access, and overall cabinet depth. Notes explain clearances related to overhead vent hoods and cabinet distances from the rangetop edge.
Cabinet and Countertop Layout (continued)
Diagram showing the top view of the cabinet cutout required for installation *without* a downdraft vent. It details minimum clearances to combustible walls above the countertop (10" or 25.4 cm) on both sides, and countertop overhangs (1/2" or 1.3 cm). It specifies an 8" W x 6" D (20.3 cm x 15.2 cm) gas/electrical utility cut-out in the right rear corner of the mounting platform if connections are routed through the bottom. Two 1/2" diameter (1.3 cm) holes are shown through the platform for hold-down bolts. The mounting platform must be at least 1" thick.
CABINET/COUNTERTOP CUTOUT DIMENSIONS WITHOUT DOWNDRAFT VENT - TOP VIEW
Model No. | B - Cutout Width | D | E |
---|---|---|---|
DRT304S | 30" (76.2 cm) | 13 3/8" (34.0 cm) | 10 1/8" (25.7 cm) |
DRT366S | 36" (91.4 cm) | 16 5/8" (42.2 cm) | 11 3/16" (28.4 cm) |
Cabinet and Countertop Layout (continued)
Diagram showing the top view of the cabinet cutout required for installation *with* a downdraft vent. It includes similar clearances to the non-downdraft view but adds a specific vent cutout (F). It notes that gas and electrical connections may only be routed through the bottom of the rangetop when installed with a downdraft vent. It also specifies minimum countertop overhangs behind the cutout (3/8" or 1.0 cm) and space behind the vent chassis to clear a stiffener.
CABINET/COUNTERTOP CUTOUT DIMENSIONS WITH DOWNDRAFT VENT - TOP VIEW
Model No. | B - Cutout Width | D | E | F - Vent Cutout |
---|---|---|---|---|
DRT304S with ERV3015* | 30" (76.2 cm) | 13 3/8" (34.0 cm) | 10 1/8" (25.7 cm) | 27 1/2" (69.9 cm) |
DRT366S with ERV3615* | 36" (91.4 cm) | 16 5/8" (42.2 cm) | 11 3/16" (28.4 cm) | 33 1/2" (85.1 cm) |
* Use only downdraft vent model specified. Downdraft vent is not compatible with DRT rangetops having a serial number starting with letters "SA."
Diagram showing the side view for installation with a downdraft vent. It details minimum countertop overhangs (3/8" or 1.0 cm) required behind the cutout and space behind the vent chassis to clear a stiffener. It indicates the minimum countertop height is 30 1/4" (76.8 cm). An "IMPORTANT" note advises consulting downdraft vent installation instructions for duct system layout/planning.